Betacom 24C combi. DHW does not rise above 40C and it keepsHi Dan Betacom 24C combi. DHW does not rise above 40C and it keeps on cycling on/off even with a steady flow of water from tap, DHW thermister recently replaced. HW demand is acknowledged by 24C so as… read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
The boiler is a Vokera compact he 29 about 6 years old. TheHi, the boiler is a Vokera compact he 29 about 6 years old. The fault is that after the central heating has been operating for around 30 mins it shuts down with the red LED on constantly suggesting an… read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
Brian, I have recently taken out a bg homecare policyHi Brian, I have recently taken out a bg homecare policy and on inspection as the existing boiler is very old, and the fan cant be replaced as obsolete , I apprantly need a new boiler. I have now had … read more
Brian
Plumber
596 satisfied customers
My Glow*worm boiler keeps cutting out. It works well sometimes,My Glow*worm boiler keeps cutting out. It works well sometimes, then it won't do anything and I'm getting a message of F4, have no idea what that means. Any advice gratefully received. Many thanks in … read more
Marc
Master plumber, oil burner technician
Vocational, Technical or Trade Scho
1,710 satisfied customers
Hi I have a gloworm ultracom 24 cx boiler when it is runningHi I have a gloworm ultracom 24 cx boiler when it is running in hot water mode for a few minutes there is a click and then a knocking noise starts which carries on till the hot water is turned off… read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
have a potterton 28he gold combi boiler, 3 yrs old. when thehave a potterton 28he gold combi boiler, 3 yrs old. when the dhw is turned on the boiler temp rises really quickly to way above the set dhw temperature and then the boiler cuts out, the temperature dr… read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
I have an old glow-worm fuelsaver mk2 30b boiler, recently ihi, i have an old glow-worm fuelsaver mk2 30b boiler, recently i have bleeded a few radiators and i dont know why the bleeding valve abowe the boiler relesed alot of air, the heating went off. i have … read more
Rick Ridley
Retired, well Semi,
30 years on the tools
2,707 satisfied customers
Hi, I have a Glow worm Ultracom 38 cxi and Drayton digistatHi, I have a Glow worm Ultracom 38 cxi and Drayton digistat +2. We have water but no heating. I have reset stat and still nothing. I have turn the heating temp to max and turned down the water below 4… read more
canuck the pro
15,602 satisfied customers
My Baxi duo-tec combi HE 40 is producing fluctuating hot waterMy Baxi duo-tec combi HE 40 is producing fluctuating hot water at the taps. We are unable to get a hot bath. The pressure is correct and we have adjusted the thermostat temp but the water is not at a … read more
Rick Ridley
Retired, well Semi,
30 years on the tools
2,707 satisfied customers
I have a ranco thermostat on a 30 year old glow worm spaceI have a ranco thermostat on a 30 year old glow worm space saver 45/60b....the ranco thermostat shuts the boiler down at 75, this is before the cylinder and heating is satisfied. What if the maximum f… read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
Hi, Im a newby to this valuable rescource and I cant seemHi, I'm a newby to this valuable rescource and I cant seem to find anything on the net relating to my problem After 3 years fault free, our Vaillant ecotec plus 624 [ all new installation at the time … read more
Rick Ridley
Retired, well Semi,
30 years on the tools
2,707 satisfied customers
I have a Glow Worm Ultracom HXI that keeps overheating (F5I have a Glow Worm Ultracom HXI that keeps overheating (F5 error message). My whole house has UFH. We thought we'd solved the problem by increasing the pipes to 22mm so the boiler could dump its heat … read more
Chamberlain Maintenance
Plumber
324 satisfied customers
Hi, could I use a single lever Triton shower unit with ourHi, could I use a single lever Triton shower unit with our Glow-worm 30cxi boiler, it looks as though I might be able to adjust water temp by just the one lever, and will it come with non return vales… read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
I have a glow worm boiler that is heating water ok but willI have a glow worm boiler that is heating water ok but will not heat up the radiators. It appears to receive the signal from the thermostat, the demand icon appears, the burners start up, the degrees … read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
Boiler issue; I have a glowworm energy saver condensingBoiler issue; I have a glowworm energy saver condensing conventional boiler. When hot water is turned on on the programmer, boiler runs for a short while, flow and return pipes get hot, then boiler sh… read more
Rick Ridley
Retired, well Semi,
30 years on the tools
2,707 satisfied customers
I have a Mynute boiler - no red light showing but when theI have a Mynute boiler - no red light showing but when the boiler gets to the set temperature it turns itself off immediately, then there is a wait for 5-10 mins the temp drops and then the boiler sta… read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.