MY 2 GLOWWORM SPACE SAVER 60BR FIRES UP BUT CUTS OFF ABOUT 1MY MARK 2 GLOWWORM SPACE SAVER 60BR FIRES UP BUT CUTS OFF ABOUT 1 MINUTE LATER PILOT LIGHT STAYS ON HAD POWER FLUSH NEW PUMP THOUGH CIRCULATION THE PROBLEM BUT STILL THE SAME ANY WAY YOU KNOW THE PROB… read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
I am living in Portugal and have a Junkers Water Boiler(Hi there, I am living in Portugal and have a Junkers Water Boiler( think the model No is H275-2 KV 1 P31 S3505. I have no hot water at the moment, if I run hot water taps the boiler does not ignite to… read more
Elliott Louis
Plumber
NVQ Level 2
15 satisfied customers
My daughter has a Glowworm Fuelsaver 40bf mkii boiler. TheHi, my daughter has a Glowworm Fuelsaver 40bf mkii boiler. The pilot light goes out about 30-60 seconds after the heating system goes off, e.g. when the timer finishes and shuts off everything, There … read more
Rick Ridley
Retired, well Semi,
30 years on the tools
2,707 satisfied customers
We have a baxi bermuda inset 2 fire / back boiler - we haveHello - we have a baxi bermuda inset 2 fire / back boiler - we have a problem with the fire - We turn the dial to turn the fire on - it ignigts - then it goes out - I was wondering if there was a way … read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
hi boiler is glowworm 24c betacom ,on central heating pumphi boiler is glowworm 24c betacom ,on central heating pump and fan work boiler lights approx 10 secs and cuts out.on hw it keeps lighting and going out within 10 secs and then relights then goes out… read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
I have a profile 80e over 10 years old, the boiler was runningI have a profile 80e over 10 years old, the boiler was running when we came home today, but the rads were only tepid, when 1 looked at the boiler it seemed as though the burners were on a low flame, r… read more
Rick Ridley
Retired, well Semi,
30 years on the tools
2,707 satisfied customers
I have a Glow Worm Majorca Radiant Convector Fire with CentralI have a Glow Worm Majorca Radiant Convector Fire with Central Heating Boiler Unit. The boiler pilot igniter head does not appear to work and I have to take off the fire unit completely to be able to … read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
Our Baxi fire heats the hot water only. There is a gas heaterOur Baxi fire heats the hot water only. There is a gas heater which heats the hot water, and if we turn down the switch heats 2 radiators in the kitchen and one in the bathroom. When we have the fire … read more
Rick Ridley
Retired, well Semi,
30 years on the tools
2,707 satisfied customers
I have a 12hxi. Installed with my redrow new build house 3I have a GlowWorm 12hxi. Installed with my redrow new build house 3 years ago. After about a 12 month in the property, I starting to get some knocking through the pipes. Redrow came and fixed this, I … read more
Rick Ridley
Retired, well Semi,
30 years on the tools
2,707 satisfied customers
I have a Halstead boiler about 16 years old and generally itI have a Halstead boiler about 16 years old and generally it has been reliable. Its a simple heat only affair for both heating and hot water both of which have thermostatic controls i.e. room stat and… read more
Al-Moderator
High School or GED
Hi, I have a glowworm compact 100p fanned flue combi boilerHi, I have a glowworm compact 100p fanned flue combi boiler in my rented accomodation. The hot water works fine but the heating keeps causing the pilot light to go out, not sure if this is the safety … read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
Boiler issue; I have a glowworm energy saver condensingBoiler issue; I have a glowworm energy saver condensing conventional boiler. When hot water is turned on on the programmer, boiler runs for a short while, flow and return pipes get hot, then boiler sh… read more
Rick Ridley
Retired, well Semi,
30 years on the tools
2,707 satisfied customers
ferroli optima 901light pilot fan running at slow speed,ferroli optima 901 light pilot fan running at slow speed, pilot established release ignition button, call for heat fan speeds up (noisily) pilot dies down to slight tips out of pilot burner, no main b… read more
Andrew Smith
Engineer
Vocational, Technical or Trade Scho
4,029 satisfied customers
hi i am working ona ravenheat 85t combi boiler,at the momenthi i am working ona ravenheat 85t combi boiler,at the moment the boiler will olny stay alight on the hot water olny setting. when switched to heating and hot water the boiler fiers up,stays alight for… read more
Rick Ridley
Retired, well Semi,
30 years on the tools
2,707 satisfied customers
How do I relight my Potterton Kingfisher II boiler. I paidHow do I relight my Potterton Kingfisher II boiler. I paid someone to relight it a couple of days ago and he told me there was a knack to it, but didn't say how to do it. Charged me £25 but I really n… read more
Rick Ridley
Retired, well Semi,
30 years on the tools
2,707 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.