Hi, I'm new here but hoping you may be able to help. I have
Hi, I'm new here but hoping you may be able to help. I have quite a large house around 30 yrs old with oil fired central heating. the original system used 22mm pipe with 15mm branches to radiators and… read more
Marc
Marc
Plumber
Vocational, Technical or Trade Scho
156 satisfied customers
Hello just came across a old central heating system (what you
Hello just came across a old central heating system (what you would assume to be open vent) it has an old back boiler, it has a feed and exspansion tank in the loft, it has a feed and an overflow pipe… read more
Andrew Smith
Andrew Smith
M&E Project Manager
Vocational, Technical or Trade Scho
3,087 satisfied customers
HelloI have reinstalled the radiators in my bungalow with
Hello I have reinstalled the radiators in my bungalow with new 15mm pipework rising to 22mm in the attic where the pump is also located. I can get hot water past the pump but only occasionally to a ra… read more
Rick Ridley
Rick Ridley
UK Heating Engineer
30 years on the tools
2,708 satisfied customers
I have regular (not combi) boiler with vented system I think.
I have regular (not combi) boiler with vented system I think. (Option 1): I am getting a ground floor extension built (2 rads) plus I would like to run pipes in case I want to turn some or all of the … read more
Andrew Smith
Andrew Smith
M&E Project Manager
Vocational, Technical or Trade Scho
3,087 satisfied customers
Shall I change hot flow pipes from 15mm to 22mm or do I need
Shall I change hot flow pipes from 15mm to 22mm or do I need extra pump in the basement? Central heating system: Boiler is Valliant eco TEC pro 28 installed three years ago and room thermostat control… read more
Brian
Brian
Plumber
596 satisfied customers
my heating and hot water stopped working but pump running and
my heating and hot water stopped working but pump running and boiler still working no errors on boiler given. I drained radiators and there was no drop in header tank, loosened pump outlet and opened … read more
Rick Ridley
Rick Ridley
UK Heating Engineer
30 years on the tools
2,708 satisfied customers
I thinking of doing a diy central heating installation to replace
I thinking of doing a diy central heating installation to replace an old single pipe system in a 3 bed semi. The boiler is a fairly new combi. Would you recommend plastic pipe and what should the basi… read more
Andrew Smith
Andrew Smith
M&E Project Manager
Vocational, Technical or Trade Scho
3,087 satisfied customers
My new boiler (12 months old) has been issued a warning notice
My new boiler (12 months old) has been issued a warning notice by the service engineer. Problem:- A big fall off of preasure between meter and combi-boiler, i.e. 20mbars to 9.3mbars. the installation … read more
Rick Ridley
Rick Ridley
UK Heating Engineer
30 years on the tools
2,708 satisfied customers
I have a wood burner feeding a thermal store. I have just connect
I have a wood burner feeding a thermal store. I have just connect two very large radiators 3metres and 2.5metrs. Everything works OK until the pump turns off and a few pints of water flows into the he… read more
Rick Ridley
Rick Ridley
UK Heating Engineer
30 years on the tools
2,708 satisfied customers
i have central heating down stairs and one rad on landing i
i have central heating down stairs and one rad on landing i want to fit four more rads in bedrooms and bathroom the existing rads are fed by 15mm pipe can i tee into system using 15mm this will make a… read more
Rick Ridley
Rick Ridley
UK Heating Engineer
30 years on the tools
2,708 satisfied customers
You helped before about overpumping into a header tank - the
You helped before about overpumping into a header tank - the problem was that the new boiler was fitted with the pump on the feed side _before_ the expansion pipe. The engineer fixed it by fitting the… read more
Rick Ridley
Rick Ridley
UK Heating Engineer
30 years on the tools
2,708 satisfied customers
Hi I am replaceing my hot air heating in my bungerlow with
Hi I am replaceing my hot air heating in my bungerlow with a combi boiler and rads is it ok to run the pipe work up though the roof space I have been told I could air locks I do not want to dig up the… read more
Andrew Smith
Andrew Smith
M&E Project Manager
Vocational, Technical or Trade Scho
3,087 satisfied customers
Added 3 radiators to gravity fed heating system, valve are
Added 3 radiators to gravity fed heating system, valve are very hot but radiator cold, turn off existing radiators and the new ones heat, turn existing back on and they go cold. Each day different rad… read more
Rick Ridley
Rick Ridley
UK Heating Engineer
30 years on the tools
2,708 satisfied customers
is 15mm polypipe good 4 a combi system plumber just finished
is 15mm polypipe good 4 a combi system? plumber just finished and done all system in 15mm?? surely it should be done in 22mm copper then branch off in 15mm copper 2 rads???… read more
Andrew Smith
Andrew Smith
M&E Project Manager
Vocational, Technical or Trade Scho
3,087 satisfied customers
Is there a clamp on tee for 15mm copper into 22mm copper pipe
Is there a clamp on tee for 15mm copper into 22mm copper pipe without the need of cutting the pipe? This is for a combi sealed heating system where access to the 22mm is very tight and both ends fixed… read more
Rick Ridley
Rick Ridley
UK Heating Engineer
30 years on the tools
2,708 satisfied customers
can I reduce my heating pipes from 15mm to 10 mm then back
can I reduce my heating pipes from 15mm to 10 mm then back up to 15mm to connect to my radiators… read more
Rick Ridley
Rick Ridley
UK Heating Engineer
30 years on the tools
2,708 satisfied customers
The Vent pipe to my expansion tank is continually recircing
The Vent pipe to my expansion tank is continually recircing water. The expansion tank is very hot and becomming a problem with condensation in the loft. This all came to light after I came back from a… read more
Rick Ridley
Rick Ridley
UK Heating Engineer
30 years on the tools
2,708 satisfied customers
how do you drain the primary circuit on a potterton performa
how do you drain the primary circuit on a potterton performa 28 in order to fit service kit to diverter valve assembly… read more
Rick Ridley
Rick Ridley
UK Heating Engineer
30 years on the tools
2,708 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Chamberlain Maintenance

Chamberlain Maintenance

Plumber

324 satisfied customers

Qualified Plumber with over 17 years experience in Domestic & Commercial plumbing.

qwasert

qwasert

Plumber

211 satisfied customers

Condensing and Combi Boilers

Marc

Marc

Plumber

156 satisfied customers

Plumbing and Heating expert with 25+ years experience, 21+yrs self employed as a contractor.

Dan_Robinson

Dan_Robinson

Plumber

33 satisfied customers

Owner and Director of Jennings Heating Ltd. Registered to work with Gas and High pressure hot water systems.

Elliott Louis

Elliott Louis

Plumber

15 satisfied customers

Lead engineer at eogasservice

Brian

Brian

Plumber

596 satisfied customers

16 yrs. experience as plumber, including full bathroom and kitchen installations.

bshull17

bshull17

Architect

2,153 satisfied customers

Licensed Architect- 17 years, L.E.E.D. AP

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.