Techdesk
Techdesk, Field Service Engineer
Category: UK Appliance
Satisfied Customers: 16409
Experience:  Whitegoods engineer working for a multibranded national company in the UK.
13782322
Type Your UK Appliance Question Here...
Techdesk is online now
A new question is answered every 9 seconds

Indesit ide750 a10 fault new water valve and air brake

Customer Question

indesit ide750 a10 fault
new water valve and air brake fitted, fills up washes for about 10 seconds then drains
Submitted: 6 years ago.
Category: UK Appliance
Expert:  Techdesk replied 6 years ago.

Hiya,

A10 indicates a fault with heating on the appliance.

This is from the service manual. 

 

A10 Open circuit in heating circuit.

  • Check open circuit heating element (26 ohms).
  • Check open circuit heater cut-out.Check pressure switch open circuit (connections 11-14).
  • Check wiring and connections between module card, pressure switch and heater.
  • If all above is OK, replace module card.

Check out the heater, wiring, pressure switch and if they are all ok, I'm afraid you need to replace the control board in the facia.

Get back to me if you need more help.

If you are unable to do the work yourself, I'm afraid you'll need an engineer to attend the appliance.

Hope this helps

Thanks