I have a single story ranch with a 4/12 pitch roof. The
I have a single story ranch with a 4/12 pitch roof. The ceiling joists above the kitchen wall are split and resting on top. The span of the house is around 20 feet. I'd like to remove the kitchen wall… read more
walkereng
walkereng
Consultant
Bachelor's Degree
5,453 satisfied customers
Beam span 13'9”,, 2x6 interior stud wall with 2nd floor
Beam span 13'9”,, 2x6 interior stud wall with 2nd floor joist ending to a 30” clear height living room. Beam will carry 2x12 joist 26” OC. Laminated beam or steel I beam size? … read more
walkereng
walkereng
Consultant
Bachelor's Degree
5,453 satisfied customers
Answers always turn into more questions, right? I'm leaning
Answers always turn into more questions, right? I'm leaning toward the 18' opening. These questions are based on that:1)The local stores only have 18" LVL (not 20") what are my options here? One store… read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
I have a post and beam house with a vaulted living/dining
I have a post and beam house with a vaulted living/dining room. The ceiling drops to 8 foot for the kitchen/ hall to front door/open stairs. The kitchen side is jutted out into the dining room about 6… read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
I want to remove a load bearing wall by creating a 10 ft
Hello, I want to remove a load bearing wall by creating a 10 ft opening. It currently has 2x4 16" off center there is a second floor that has a 4 x 8 standard for beam. Then a drop ceiling of 2 x 6. T… read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
My house is 28 ft x 60 ft. Near the center of house is a
My house is 28 ft x 60 ft long. Near the center of house is a kitchen that is 12ftx16ft, with a load bearing wall between it and living room. The living room is 16ft x 16 ft. Between the two rooms is … read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
I want to remove a portion of a wall between my kitchen and
I want to remove a portion of a wall between my kitchen and living room and am trying to determine if it is load bearing and if I need to add a support beam. Looking at the wall from left to right the… read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
I am building a 58' 4" wide 38' 8" deep house it has a 20 x
i am building a 58' 4" wide 38' 8" deep house it has a 20 x 28 loft over the 3 bedrooms. the beam will be 20'11 from front 17'9 from rear to get it under main hall wall, 3 columns 14.58 ft from each o… read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
I would like to replace my two garage doors into a single
Hi. I would like to replace my two garage doors into a single double door. Single-story garage, 24ft wide x 20ft deep. 8ft walls. 15psf dead load, 25psf snow load. Garage door opening - 17ft. Thinking… read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
Looking at doing a 2x8 beam on south wall of house for
Looking at doing a 2x8 beam on south wall of house for garage door opening. Planning on using flitch plate with triple 2x8's and steel sitting on top of the sill plate if I use 1/2" steel, what hole s… read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
Former owner added a 9' x 7' garage door to eave side of
Former owner added a 9' x 7' garage door to eave side of detached 20' x 20' garage without proper header framing. The garage walls are only 8' high, so I don't have room for 10" or 12" LVL beam. I wil… read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
I want to open up the wall between my kitchen and living room.
I want to open up the wall between my kitchen and living room. The wall is load bearing. The joists are 2x4 16 inch oc and the attic is non storage non occupied. The attic does hold the HVAC ducts, el… read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
Looking to split the load of a single lally across two
Looking to split the load of a single lally across two columns and support the beam with steel U channel. the lally is at the butt joint of a 20' and 16' span of a 6x8 main beam … read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
My house is one story with basement. House is 28 feet wide
My house is one story with basement. House is 28 feet wide and has 2x10 yellow pine floor joist 16" OC. The center beam is 4 2x10's that runs the 44 ft length of the basement.. This Center beam is sup… read more
walkereng
walkereng
Consultant
Bachelor's Degree
5,453 satisfied customers
I have an existing wooden beam that consists of 3- 1 1/2" x
I have an existing wooden beam that consists of 3- 1 1/2" x 9" x14' nailed together , however two are spliced! Only see glue on one board not the other. The beam deflected about 1 1/8". Some termite d… read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
Question: Architect plan calls 2x12's ML as a header
Question: Architect plan calls for 2 2x12's ML as a header for a span of 8 feet, for a new 3 panel Andersen patio door. The header will also help support a new story to be added above. What size steel… read more
StructuralEng
StructuralEng
Consultant
Bachelor's Degree
8,463 satisfied customers
what dimension steel I beam is required to clear span 22,
what dimension steel I beam is required to clear span 22', with a 10 psf dead load and 40 psf live load (floor load only, roof already exists) ? what dimension required if same span were to be split i… read more
walkereng
walkereng
Consultant
Bachelor's Degree
5,453 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

He answered my question promptly and gave me accurate, detailed information. If all of your experts are half as good, you have a great thing going here.

DianeDallas, TX

< Previous | Next >

Meet the Experts:

vgdlpc

vgdlpc

Master's Degree

17 satisfied customers

Civil Engineer, Major in Structures and Foundations. Professional Engineer 11 years of experience.

StructuralEng

StructuralEng

Consultant

8,463 satisfied customers

Structural Engineer

walkereng

walkereng

Consultant

5,453 satisfied customers

Over 35 years of Structural Engineering experience.

Shannon Galway

Shannon Galway

-

208 satisfied customers

VP Technical Services at Major Engineering Company

JAYCEG

JAYCEG

99 satisfied customers

Expert

William Purpura

William Purpura

Managing General Partner

52 satisfied customers

Managing General Partner at Dargon Developement

PaulH471

PaulH471

Construction Manager

46 satisfied customers

Expert

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x