I have a Honda 5000 generator that only puts out 110 when
I have a Honda 5000 generator that only puts out 110 when switch to 240 and puts out nothing when switch back to 110 … read more
TIMOTO
TIMOTO
Bachelor's Degree
1,326 satisfied customers
I have a Honda em5000s generator not producing power. I
I have a Honda em5000s generator not producing power … read more
Hank F.
Hank F.
Technician
High School or GED
17,332 satisfied customers
Hank, I have a honda EM3500sx serial number EA6-1004767. The
Hey Hank, I have a honda EM3500sx serial number EA6-1004767. The engine runs great. The voltage meter reads 110 volts, however, output is only 98 volts as I measured it at the 110 sockets (both the 20… read more
Hank F.
Hank F.
Technician
High School or GED
17,332 satisfied customers
I have a Honda EM 6500 SX and it was running fine very
I have a Honda EM 6500 SX and it was running fine very well-maintained the 120 V outlets is only reading 40 and the 240 is only reading 120 … read more
TIMOTO
TIMOTO
Bachelor's Degree
1,326 satisfied customers
i have a honda em 5000 sx generator i start it it runs rough
i have a honda em 5000 sx generator i start it it runs rough black smoke like the choke is on slowly revs up then dies… read more
Hank F.
Hank F.
Technician
High School or GED
17,332 satisfied customers
I have a Honda EW171 welder/generator. While in use the auto
I have a Honda EW171 welder/generator. While in use the auto throttle will stop working and the generator and welder will also stop working at the same time. When the auto throttle will resume working… read more
Hank F.
Hank F.
Technician
High School or GED
17,332 satisfied customers
I have a Honda Em 6500 sx generator thats about 5 years old.
I have a Honda Em 6500 sx generator that's about 5 years old. Its quit putting out any voltage. This was verified with a meter at the terminal strip on the stator. Any suggestions? Thanks… read more
TIMOTO
TIMOTO
Bachelor's Degree
1,326 satisfied customers
I have a Briggs and Stratton Portable Generator Model 030235.
I have a Briggs and Stratton Portable Generator Model 030235. I think I overloaded it today. It's has no power on 110 or 220 outlets. I checked the circuit breaker and it has continunity so I guess it… read more
Hank F.
Hank F.
Technician
High School or GED
17,332 satisfied customers
I have a Kohler 7.00k21 generator that dosent put out power.
I have a Kohler 7.00k21 generator that dosen't put out power. The engine runs but when I hook a multi meter to the connection between the generator output and the RV there is no power… read more
Hank F.
Hank F.
Technician
High School or GED
17,332 satisfied customers
I have a Honda EG2500XK1 JPN EZCR-1067440 During a power
I have a Honda EG2500XK1 JPN EZCR-1067440 During a power fail..I started it, and plugged in a power cord to operate a 7 amp 120V Reefer, and a lamp . all was working great..then.. The lamp started pul… read more
Hank F.
Hank F.
Technician
High School or GED
17,332 satisfied customers
I Have a old Honda EG 1500. which was running and producing
I Have a old Honda EG 1500. which was running and producing power, when electrical load was turned off engine sped up then dropped to low speed and would not rev although throtle was wide open and no … read more
Hank F.
Hank F.
Technician
High School or GED
17,332 satisfied customers
I have a honda rv type generator it will start when you hold
I have a honda rv type generator it will start when you hold down start button let it go mottor stops… read more
Hank F.
Hank F.
Technician
High School or GED
17,332 satisfied customers
I have a Honda EM5000sx, motor runs great, nice and smooth,
I have a Honda EM5000sx, motor runs great, nice and smooth, starts on one pull every time. Problem is no power to out lets, doesn't even register on the volt meter and green "power" light doesn't come… read more
TIMOTO
TIMOTO
Bachelor's Degree
1,326 satisfied customers
I have a Honda EX5000 generator. It hasnt been used much.
I have a Honda EX5000 generator. It hasn't been used much. The last time I used it, everything worked fine for 2 days. On day 3, it started up fine, but could not get any elec power from it. Is there … read more
TIMOTO
TIMOTO
Bachelor's Degree
1,326 satisfied customers
I have a honda generator model em 5000 s that starts and runs
I have a honda generator model em 5000 s that starts and runs fine. checked everything i can but it does not put out any electricity… read more
TIMOTO
TIMOTO
Bachelor's Degree
1,326 satisfied customers
My generator starts and runs fine for about 45 minutes and
My generator starts and runs fine for about 45 minutes and stops. It will start right back up but runs for about 5 minutes. Changed fuel, air, oil and oil filter. Same result. Any ideals? faction I wa… read more
Hank F.
Hank F.
Technician
High School or GED
17,332 satisfied customers
Honda 5KW Engine starts, runs. No output, no voltmeter
Honda 5KW Engine starts, runs. No output, no voltmeter reading, no green light. Unit worked fine on last use.… read more
TIMOTO
TIMOTO
Bachelor's Degree
1,326 satisfied customers
I own a generac exl7500 . I bought it used and after using
I own a generac exl7500 . I bought it used and after using it a few times it quit making power. I removed the cover on the end opposite the motor and found the battery charge rectifier melted badly. t… read more
Hank F.
Hank F.
Technician
High School or GED
17,332 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Rick

Rick

Factory Authorized Trainer

4,218 satisfied customers

Outdoor Power Equipment technical trainer since 1990, covering eight states.

Vince O.

Vince O.

Small Engine Technician

3,158 satisfied customers

Over 30 years experience repairing lawn and garden equipment. Chainsaws, mowers,blowers and trimmers

Jon K.

Jon K.

Small Engine Diagnostic Expert

2,995 satisfied customers

Gold certified Stihl tech, Service Manager for a rental/repair shop.Certified in most small engines

James W

James W

Small Engine Troubleshooting Expert

2,987 satisfied customers

7 years as Mechanic & Parts Manager for Brother who has Owned Lawn & Garden Repair shop for 35 years

RUSS

RUSS

SERVICE TECHNICIAN

1,723 satisfied customers

28 YEAR SERVICE TECHNICIAN

CJBennett

CJBennett

Small Engine Technician

624 satisfied customers

Briggs and Stratton Master Service Tech, Kohler, Tecumseh, Kawasaki certified. 18 years exp.

Chris Huber

Chris Huber

Small Engine Technician

576 satisfied customers

20 years experience. Briggs and Stratton Master Service Technician. Dealer for most engine lines.

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.