We had our coast spa running last nite( its new to us but

Customer Question

We had our coast spa running last nite( its new to us but been filled for about a week but only turned on last nite. Today when we turn the jets on they will not stay running for more than 4-5 seconds. We have bled the lines a couple times to try and fix . Flo error code. Pump is flashing as well
Submitted: 1 year ago.
Category: Pool and Spa
Expert:  Billy replied 1 year ago.

hello,

is the main circulating pump running? This must run before we make the flow switch contact..

Customer: replied 1 year ago.
Runs for 4-5 seconds and then shuts off
Expert:  Billy replied 1 year ago.

thank you...that is our issue....we need to see if the pump motor has power but stops....or if it stops because power drops out. This will require a meter.