Hi have issue with 2016 volvo with fault code regen in a loop the only thing that is comming up though most of the stuff is replaced starting with egr finishing up with inter cooler the only thing not replaced is turbo though i did replace turbo actuator...

Mechanic's Assistant: Have you seen this error before with the same vehicle?

No

Mechanic's Assistant: What's the model of your 2016 Volvo?

2016 volvo d13 vn

Mechanic's Assistant: Hi there. Is there anything else the Volvo Mechanic should know before I connect you? Rest assured that they'll be able to help you.

That would be it

Submitted: 1 year ago.Category: Medium and Heavy Trucks
Show More
Show Less
Ask Your Own Medium and Heavy Trucks Question
Answered in 1 minute by:
8/20/2021
Technician: Mike Mcmillan, Shop Foreman/Triage Tech replied 1 year ago
Mike Mcmillan
Mike Mcmillan, Shop Foreman/Triage Tech
Category: Medium and Heavy Trucks
Satisfied Customers: 6,607
Experience: Volvo/Mack Master Tech, Certified with Cummins, Eaton, GM, Hino, Detroit Diesel
Verified

Hello and thank you for using Just Answer. My name is ***** ***** I’d like to try and help. I am sorry that you are having issues with your truck. I know this can be frustrating. Please allow me a few moments to look over your question and I will be right back with you.

Ask Your Own Medium and Heavy Trucks Question
Technician: Mike Mcmillan, Shop Foreman/Triage Tech replied 1 year ago

The first thing I would do is make sure both the ecm and acm software is up to date. There are revisions for this error. I would then run a regen and monitor the t2 and 3 sensors and make sure they are running 850 plus. Check the injector actuation percentage and see if it shows it maxed out. I would also make sure the learned data reset has been done when the parts were replaced as well

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 1 year ago
Injectors checked software is up to date like I said 2-3 both doesn’t reach more when 610
Technician: Mike Mcmillan, Shop Foreman/Triage Tech replied 1 year ago

What happens when you run the crystal sub test

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 1 year ago
It doesn’t do it it just trying to raise a temperature in dpf like I said it should be around 660 and it raises it till 600
Technician: Mike Mcmillan, Shop Foreman/Triage Tech replied 1 year ago

Okay. What is the injector percentage at when it is running?

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 1 year ago
First 4 injectors between-4 to -10% and 5th is 20% and 6 is 7%
Technician: Mike Mcmillan, Shop Foreman/Triage Tech replied 1 year ago

On the 7th injector.

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 1 year ago
I don’t know what else there is to tell
Technician: Mike Mcmillan, Shop Foreman/Triage Tech replied 1 year ago

I would pull the dpf and see if it shows any fiberglass inside of it from the flex pipe coming apart. If that is fine I would try putting a catalyst in it.

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 1 year ago
Flex pipe is brand new and also it’s new dpf replaced too
Technician: Mike Mcmillan, Shop Foreman/Triage Tech replied 1 year ago

Okay, Can you please list all of the parts that have been replaced on this unit?

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 1 year ago
Turbo actuator, egr ,egr cooler, 7th injector , lines to 7th injector , 7 th injector module, flex pipe, catalyst, dpf filter
Technician: Mike Mcmillan, Shop Foreman/Triage Tech replied 1 year ago

I would check the reading on the EGR differential pressure sensor and make sure it is reading a good zero, Make sure there are no indication that the egr valve is staying open. Try to recalibrate the turbo and run the motor effort test to make sure it is not sticking when it gets hot. If moving the sector shaft by hand you hear a noise when moving the turbo is probably hanging up. Make sure the boost pressure and intake air temp is not reading biased as well. If that is fine, please provide the MSW numbers before and after the update and I will see what changes were made.

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 1 year ago
What is exactly MSW?
Customer reply replied 1 year ago
Plus all updates there done already and differiantal pressure sensor is replaced
Technician: Mike Mcmillan, Shop Foreman/Triage Tech replied 1 year ago

MSW is the main software level.

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 1 year ago
The only thing left not replaced is turbo charger I start to think just to replace turbo though no fault codes and with it though it was overheated before
Customer reply replied 1 year ago
Replaced turbo didn’t helped any other ideas? Can injectors cause not raising temperature? Apparently part # is wrong from 2014 is different set up and this one 2016
Was this answer helpful?

How JustAnswer works

step-image
Describe your issueThe assistant will guide you
step-image
Chat 1:1 with a technicianLicensed Experts are available 24/7
step-image
100% satisfaction guaranteeGet all the answers you need
Ask Mike Mcmillan Your Own Question
Mike Mcmillan
Mike Mcmillan
Mike Mcmillan, Shop Foreman/Triage Tech
Category: Medium and Heavy Trucks
Satisfied Customers: 6,607
6,607 Satisfied Customers
Experience: Volvo/Mack Master Tech, Certified with Cummins, Eaton, GM, Hino, Detroit Diesel

Mike Mcmillan is online now

Related Medium and Heavy Trucks Questions
I have a code P226C00 on my 2016 Volvo VNL. I changed the
HelloI have a code P226C00 on my 2016 Volvo VNL. I changed the turbo and vgt recentely. I had also very often Parked Regen required, like 3 times a day while driving at highway speed.… read more
Mike D
Mike D
Mechanic Shop foreman
diesel technology
2 satisfied customers
I HAVE A 2016 VOLVO VNL THAT HAS 4 CODES AS FOLOW: DTC
HELLO, I HAVE A 2016 VOLVO VNL THAT HAS 4 CODES AS FOLOW: DTC P004607 DTC P269800 DTC P027F00 DTC P026D00 I already changed the NOX sensors (both) I used aftermarket ones. The code for the EGR came af… read more
Mike Mcmillan
Mike Mcmillan
Shop Foreman/Triage Tech
Associates
6,607 satisfied customers
I have volvo d13 2016 it doesn't raise temperature for Regen
Hi I have volvo d13 2016 it doesn't raise temperature for Regen though the outlet temp sensor doesn't go higher when 800 F it's supposed to be between(###) ###-####no exhaust leaks no intake leaks tur… read more
Mike Mcmillan
Mike Mcmillan
Shop Foreman/Triage Tech
Associates
6,607 satisfied customers
I have volvo d13 semi, i have active fault connected with
i have volvo d13 semi , hello i have active fault connected with egr temp sensor , is it drivable like this or requires imediate replacing of that .. just pops up 20 min ago and becomes inactive and n… read more
Mike Mcmillan
Mike Mcmillan
Shop Foreman/Triage Tech
Associates
6,607 satisfied customers
I have a Volvo VN road tractor 2016 with a D13 engine. The
I have a Volvo VN road tractor 2016 with a D13 engine. The warning triangle and the amber “check” warning light come on when the engine is under load and only goes 30Mph up hills. There are no active … read more
Mike Mcmillan
Mike Mcmillan
Shop Foreman/Triage Tech
Associates
6,607 satisfied customers
Need help w/2014 Volvo D13. It's not a our fleet truck and
Hi Mike, Need help w/2014 Volvo D13. It's not a our fleet truck and was brought from outside carrier. Truck was not doing regen and Volvo dealership in MI replaced injectors. Week later had again rege… read more
Mike Mcmillan
Mike Mcmillan
Shop Foreman/Triage Tech
Associates
6,607 satisfied customers
2011 6.7 in a freightliner. Truck is having excessively
2011 6.7 in a freightliner. Truck is having excessively frequent regens. Not able to locate any exhaust leaks at this time. Regen analysis says turbo exceeded max speed. Getting code for turbo actuato… read more
Mike Mcmillan
Mike Mcmillan
Shop Foreman/Triage Tech
Associates
6,607 satisfied customers
2014 volvo vnl D13 Code P20EE00 Vin#FN937924 What is most
2014 volvo vnl D13 Code P20EE00 Vin#FN937924 What is most likely cause of this fault accruing if the dpf and doc have been cleaned, both nox sensors replaced, new egr cooler and the def injector teste… read more
Mike Mcmillan
Mike Mcmillan
Shop Foreman/Triage Tech
Associates
6,607 satisfied customers
Rpm going up and down when stranding d13 2010. VN d13 on
I have chked turbo actuator+ turno shaft. Injectors all good. … read more
Mike Mcmillan
Mike Mcmillan
Shop Foreman/Triage Tech
Associates
6,607 satisfied customers
2013 Volvo VNL, D13. SCR Performance codes. 4094 and 5394.
2013 Volvo VNL, D13. SCR Performance codes. 4094 and 5394. Wanted your opinion. Here's what the dealer came back with today:"Tech performed Dosing test 2 and 3. Test 2= 55ml and test 3= 220ml. Checked… read more
Mike Mcmillan
Mike Mcmillan
Shop Foreman/Triage Tech
Associates
6,607 satisfied customers
HERE IS THE CODES COME UP ON DIAGNOSTICS SCREEN: DTC
HERE IS THE CODES COME UP ON DIAGNOSTICS SCREEN: JA: What's the make/model/year of your truck? Engine type? Customer: DTC P24A000 JA: Are you fixing your truck yourself? What have you tried so far? Cu… read more
Mike Mcmillan
Mike Mcmillan
Shop Foreman/Triage Tech
Associates
6,607 satisfied customers
I have a 2011 Volvo VN640 with Volvo D13 motor. Getting
I have a 2011 Volvo VN640 with Volvo D13 motor. Getting code:Variable Geometry Turbocharger Actuator #1 Abnormal update rate MID 128 SID 27 FMI 9Experiencing significant loss of power.… read more
Mike Mcmillan
Mike Mcmillan
Shop Foreman/Triage Tech
Associates
6,607 satisfied customers
Guys I have 2015 Volvo and Check is Potter me couple nights.
Hi guys I have 2015 Volvo and Check is Potter me couple nights … read more
Mike Mcmillan
Mike Mcmillan
Shop Foreman/Triage Tech
Associates
6,607 satisfied customers
I have Volvo truck d16 2007 Fails Regen due to code ppid 338
I have Volvo truck d16 2007 Fails Regen due to code ppid 338 mid128 Says egr deferential pressure mechanical not responding. Help please what to do to solve this problem. Thanks… read more
Jackie Dempsey
Jackie Dempsey
Heavy Line Technician
Automotive and Diesel Engines
130 satisfied customers
Check engine code on Volvo D13 is showing air purge valve
Check engine code on Volvo D13 is showing air purge valve stuck open on aftertreatment, what can happen and how do I fix it… read more
Daniel Wilson
Daniel Wilson
Auto Mechanics 1&2/diesel mech
6,062 satisfied customers
Working on a international pro start Cummins 2010 truck came
Hello sir working on a international pro start Cummins 2010 truck came in with no power and seem to die out replaced the dpf filter it was clogged and broken reset the ecm with a new dpf and truck see… read more
cumminsdr
cumminsdr
Mechanic
High School or GED
1,886 satisfied customers
Sir I got This Volvo 2014 vn with d13 engine at my shop Got
Hello sir I got This Volvo 2014 vn with d13 engine at my shop Got a code for SPN 2659 Egr flow rate Fmi 18 flow too low The egr valve is ok What could cause this A clogged egr cooler Should I clean it… read more
Jeremy
Jeremy
Certified Truck/Bus Technician
Associate Degree
2,756 satisfied customers
I need wiring diagram / schematic VN ECM Version 3 VIN
Hello I need wiring diagram / schematic for Volvo VN ECM Version 3 VIN 149908 Year is 2015… read more
Daniel Wilson
Daniel Wilson
Auto Mechanics 1&2/diesel mech
6,062 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

He answered my question promptly and gave me accurate, detailed information. If all of your experts are half as good, you have a great thing going here.

DianeDallas, TX

< Previous | Next >

Meet the Experts:

Daniel Wilson

Daniel Wilson

6,062 satisfied customers

Owner at DJ Wilson

Cat Man

Cat Man

Cat Engine Expert

5,353 satisfied customers

I am ASE Master Truck Certified.

Wayne

Wayne

Journeyman

5,115 satisfied customers

worked on, Gmc, Macks, Freight liner,Mercedes Benz,,Ford, sterling

Jeremy

Jeremy

Certified Truck/Bus Technician

2,756 satisfied customers

ASE Med/HD Truck Technician, NATEF Diesel Engines and Electrical/Electronics Technician, Network Engineer specializing in CAN faults, Aftertertreatment, and vehicle communications

Curtis B.

Curtis B.

Technician

1,947 satisfied customers

Technician turned service manager on multiple lines of trucks and engines, used in industry.

cumminsdr

cumminsdr

Mechanic

1,886 satisfied customers

All types of Cummins applications

Chris (aka-Moose)

Chris (aka-Moose)

Technician

641 satisfied customers

24 years of experience diagnosing & repairing

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x