I'am working on a 1999 CAT 3406E in a freightliner truck,

Customer Question
Hi, I'am working on a...
Hi, I'am working on a 1999 CAT 3406E in a freightliner truck, the truck has been sitting for 4 months and now it will not start. I scanned the engine there are no active fault codes, I'm almost certain its a fuel supply issue. I have ran a line from the fuel transfer pump into a pail of clean diesel fuel, when I check the ouput pressure coming directly off the pump I get a reading of 40 psi at full cranking speed after about 30 seconds of cranking. When I hook the fuel output line back up to the filter head I cant seem to get the hand pump to get hard after I stroke it several times. the hand primer pump is brand new. any idea what the fuel pressure should be at cranking speed or do you have any ideas why this thing wont start.
Submitted: 7 months ago.Category: Medium and Heavy Trucks
Show More
Show Less
Ask Your Own Medium and Heavy Trucks Question
Answered in 14 minutes by:
1/17/2018
Technician: cat_engines_only, Other replied 7 months ago
cat_engines_only
Category: Medium and Heavy Trucks
Satisfied Customers: 2,580
Experience: Repair CAT machines only
Verified

Hello,

Generally, all 3406E, C15, C16 and C18 engines have 80 to 100 psi fuel pressure.

If this fuel transfer pump has a plug for a relief valve on it, the internal pressure regulator is 105 psi. If you have the internal regulator, you can install a gauge deadhead on the line to read the pressure directly on the pump. (not inline but dead into the end of the hose)

Since you are getting such low pressure I would suspect the pump is worn out. Try a deadhead test and if pressure is still low, replace the pump.

If pressure returns to normal, check the pressure regulator on the filter base or return port. (Usually, this is a plug with a 1-inch hex head that contains a pressure check valve in the plug.)

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 7 months ago
with the pressure guage installed directly into the end of the pump output hose I'm getting between 38 and 40 psi at full cranking speed for 30 seconds.
Customer reply replied 7 months ago
is the spec of 80-100 psi at cranking speed or the engine at idle?
Technician: cat_engines_only, Other replied 7 months ago

If you have a small plug on the pump, you can inspect the relief valve to see if it has trash stuck in it. Otherwise, you will need to replace it.

Pressures are for a running engine. I am not certain about what it would be at cranking. 40 psi should be enough for starting but, the engine will be very weak.

Have you checked for air in the supply or return lines?

Have you checked for voltage at the injectors?

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 7 months ago
I have all the lines on the pump by passed. the inlet line is going into a pail of diesel fuel, the pump output line is hooked directly to the pressure guage.
Technician: cat_engines_only, Other replied 7 months ago
I will OPT-OUT since I have limited truck experience and am not available until late this evening. Another expert will help you shortly.
Ask Your Own Medium and Heavy Trucks Question
Technician: Daniel Wilson,
 replied 7 months ago
Daniel Wilson
Category: Medium and Heavy Trucks
Satisfied Customers: 6,892
Experience: Owner at DJ Wilson
Verified

Hi ,My name is***** will be glad to help. We can follow up as needed on here, Give me some time to review your information and post my responses. Im not an employee of the site but I help on here as time allows in between jobs. Response time will vary depending on my work load , etc.

Ask Your Own Medium and Heavy Trucks Question
Technician: Daniel Wilson,
 replied 6 months ago

Hi Dave, Did you get this resolved? for some reason this got lost in the archives. If not and if fuel pressure and supply is good and free from leaks sucking air or restrictions check for cam sensor signal at the top left of the front timing cover. A loss of cam sensor signal will disable injection. Fuel pressure should be 70 to 90 psi. If low it could be a faulty transfer pump or pressure regulator. Let me know

Ask Your Own Medium and Heavy Trucks Question
Technician: Daniel Wilson,
 replied 6 months ago

If you got this resolved let me know as well so we can get this closed out.

Ask Your Own Medium and Heavy Trucks Question
Was this answer helpful?

How JustAnswer works

step-image
Describe your issueThe assistant will guide you
step-image
Chat 1:1 with a technicianLicensed Experts are available 24/7
step-image
100% satisfaction guaranteeGet all the answers you need
Ask Daniel Wilson Your Own Question
Daniel Wilson
Daniel Wilson
Daniel Wilson
Category: Medium and Heavy Trucks
Satisfied Customers: 6,892
6,892 Satisfied Customers
Experience: Owner at DJ Wilson

Daniel Wilson is online now

A new question is answered every 9 seconds

How JustAnswer works:

  • Ask an ExpertExperts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional AnswerVia email, text message, or notification as you wait on our site. Ask follow up questions if you need to.
  • 100% Satisfaction GuaranteeRate the answer you receive.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

He answered my question promptly and gave me accurate, detailed information. If all of your experts are half as good, you have a great thing going here.

DianeDallas, TX

< Previous | Next >

Meet the Experts:

Daniel Wilson

Daniel Wilson

6,892 satisfied customers

Owner at DJ Wilson

Cat Man

Cat Man

Cat Engine Expert

4,530 satisfied customers

I am ASE Master Truck Certified.

Wayne

Wayne

Journeyman

2,892 satisfied customers

worked on, Gmc, Macks, Freight liner,Mercedes Benz,,Ford, sterling

Jeremy

Jeremy

Certified Truck/Bus Technician

2,243 satisfied customers

ASE Med/HD Truck Technician, NATEF Diesel Engines and Electrical/Electronics Technician, EPA 608/609 HVAC Certified, Steering/Suspension and ABS/Brakes Technician

cumminsdr

cumminsdr

Mechanic

1,351 satisfied customers

All types of Cummins applications

Curtis B.

Curtis B.

Technician

991 satisfied customers

Technician turned service manager on multiple lines of trucks and engines, used in industry.

dieseldan55

dieseldan55

Contractor

74 satisfied customers

Road Service mechanic for Volvo Construction.

< Previous | Next >

Related Medium and Heavy Trucks Questions
I have a 2000 peterbilt with a cat 3406e, won't start
I have a 2000 peterbilt with a cat 3406e, won't start without using ether or wd40. I came up with flash codes 13 and 31. I replaced the fuel temp sensor and the primer, still the same. I also unplugge… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
I HAVE A CAT ENGINE 3126 1998 MODEL THAT IS RUNNING RUFF
I HAVE A CAT ENGINE 3126 1998 MODEL THAT IS RUNNING RUFF WITH NO POWER THE FUEL PRESSURE IS JUMPING BETWEEN 65 AND 110 PSI BUT THE HIGH PRESSURE SIDE LOOKS GOOD ON THE COMPUTER … read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
I have a freightliner with a cat c7 engine, will not start.
I have a freightliner with a cat c7 engine, will not start. Turns over fine. Power and ground at ecm. Flash codes are 58. Cat et shows cold start and no engine speed. Replaced speed sensors and fuel r… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
On a c-12 cat is there a schematic on what pins should have
on a c-12 cat is there a schematic on what pins should have power from ecm to turn on injectors i have a c-12 that cranks no start and no codes only fires on ether… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
Caterpillar C7 ACERT in a 2005 Freightliner M2. Engine was
Caterpillar C7 ACERT in a 2005 Freightliner M2. Engine was using oil and low on power. Owner wanted new engine. Removed engine and installed reman long block. Had to transfer oil pan and main oil pump… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
How is your service priced? Cat 3126 in '99, Trying to! New
Trying to! New speed/timing sensor, new fuel transfer pump, checked power to ecm (from harness side), pin 70 has 9.8 to 10 volts when cranking, Fuel restrictor at back of head works, with no sign of metal fragments. Also, sprayed contact cleaner on both ECM pins and sockets. This cat 3126 is in '99 GMC. Engine serial #7AS79444. Oh, cannot check flash codes as vehicle does not have cruise control. … read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
Keeps building pressure in the fuel line, pushing the
Keeps building pressure in the fuel line, pushing the plunger out of the primer, just replaced all the injectors and is backing plunger out of the fuel primer. … read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
There are two spin on fuel filters on my 03 387 my truck is
There are two spin on fuel filters on my 03 387 my truck is sucking air into fuel system. I have a o3 Pete with a 3406e cat. One filter is located below hand pump the other filter is on frame and has … read more
Daniel Wilson
Daniel Wilson
Auto Mechanics 1&2/diesel mech
6,892 satisfied customers
Mr CAT Man, 2002 Caterpillar C7 3126 7.2 liter Engine Engine
Mr CAT Man, 2002 Caterpillar C7 3126 7.2 liter Engine Engine Serial Number: C7KM44559 COMPLAINT: Of the mornings truck has plenty of power, runs great. The longer the day goes by making deliveries,the… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
I have a C12 Cat that is feeding fuel back thru the pickup
I have a C12 Cat that is feeding fuel back thru the pickup tube to the fuel tank when I try to pressurize the fuel system, any ideas?… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
Cat Man, I'am working on 1999 c-12 CAT serial # *****
Hi Cat Man, I'am working on 1999 c-12 CAT serial # ***** it is in a sterling truck. The engine will start right away but sometimes after about 45 seconds of running it will stall out, if you give the … read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
Hi Cat Man, Iam working on 3406E Cat serial number 5EK78587.
Hi Cat Man, I'am working on 3406E Cat serial number 5EK78587. The engine runs really nice and it is able to get up to full RPM, the problem is the engine is making little to no boost ( 0.7 to 1 lbs) a… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
Have a 3126 cat ckm that will not start. Replaced heui after
Have a 3126 cat ckm that will not start. Replaced heui after local diesel shop plugged their computer into it. It started and ran for several minutes died and will not start. Have a gauge in oil line … read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
I have a Caterpillar 3406E engine serial number 2W500550 that
I have a Caterpillar 3406E engine serial number 2W500550 that does not run properly at times loaded. At other times runs fine with load. NO error codes on computer. Primary fuel filter is only 1/5 th … read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
Have a peterbilt truck with a 3406e engine. I changed a fuel
Have a peterbilt truck with a 3406e engine. I changed a fuel tank and the truck ran for about 5 minutes then it quit and we cannot get it started.. The new tank was empty when we started it… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
Hi Cat Man, Iam working on a 1999 Peterbilt 379 with a 3406E
Hi Cat Man, I'am working on a 1999 Peterbilt 379 with a 3406E CAT in it, after sitting for a couple of days it will start up right away like usual but after about 10 seconds it will stall out.To get i… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
I have a 2005 chevy kodiac 7500 dump truck with an auto. transmission.
I have a 2005 chevy kodiac 7500 dump truck with an auto. transmission. The engine is a Cat. C7 #3126. One of my workers ran the truck out of fuel and I can not get it started. I have fuel at the water… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
I have a 1995 Peterbilt with a 3406E Cat in it. fuel pressure
I have a 1995 Peterbilt with a 3406E Cat in it. fuel pressure is running 70-75 psi at idle and 95-100 psi under load going down the highway. pressure will randomly drop to 45-50 psi when shifting thro… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,530 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x