Medium and Heavy Trucks

Have Truck Repair Questions? Ask an Expert

Ask an Expert,
Get an Answer ASAP!

Medium and Heavy Trucks

2009 Freightliner with Series 60 (EPA07). Code for High Soot…

Customer Question
2009 Freightliner with Series 60...
2009 Freightliner with Series 60 (EPA07). Code for High Soot level (zone 5). DOC inlet temp doesn't go past 495 degrees. DOC stops around 515 and DPF temp is at 495. Checked for exhaust leaks = none found. Inspected ITV operation = works fine. I checked the parameters with a similar truck = both are the same. Pulled DOC off and checked for plugging - blew out carbon with compressed air (catalyst looks fine from the back side). Can't perform a cylinder cut out test due to it being in a Zone 5 state. I really need help.- Scott
Submitted: 1 month ago.Category: Medium and Heavy Trucks
Show More
Show Less
Ask Your Own Medium and Heavy Trucks Question
Answered in 35 minutes by:
1/5/2018
Technician: Daniel Wilson,
 replied 1 month ago
Daniel Wilson
Category: Medium and Heavy Trucks
Satisfied Customers: 6,196
Experience: Owner at DJ Wilson
Verified

Hi ,My name is***** will be glad to help. We can follow up as needed on here, Give me some time to review your information and post my responses. Im not an employee of the site but I help on here as time allows in between jobs. Response time will vary depending on my work load , etc.

Ask Your Own Medium and Heavy Trucks Question
Technician: Daniel Wilson,
 replied 1 month ago

Please post the full fault code numbers with SPN and FMI numbers

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 1 month ago
SPN 3719 FMI 0 ---- Soot Level Very High (active)
Technician: Daniel Wilson,
 replied 1 month ago

no other codes? If not try a parked regen

SPN 3719 FMI 0 ---- Soot Level Very High

Check as follows:
1. Connect DiagnosticLink™.
2. Turn the ignition ON (key ON, engine OFF).
3. Check for multiple codes. Are any ACM fault codes also present?
a. Yes; troubleshoot the other faults first.
b. No; Go to step 4.
4. Check for proper configuration of the CPC against the server information. Does the CPC have the proper
configuration?
a. Yes; replace the CPC. Refer to Original Equipment Manufacturer (OEM) literature.
b. No; reprogram the CPC with the correct the information as necessary. Go to step 5. to verify repair.
5. Clear fault codes. Turn ignition OFF and disconnect DiagnosticLink. Wait five minutes for all modules to power down.
Verify repair.

Ask Your Own Medium and Heavy Trucks Question
Technician: Daniel Wilson,
 replied 1 month ago

Please take a moment to rate as that is how the site credits my time helping on the site or let me know if you need more help. 5 star and bonuses are always greatly appreciated.

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 1 month ago
I replaced the CPC with one from another truck (same year and engine). Still can't get the DOC inlet temps high enough.
Technician: Daniel Wilson,
 replied 1 month ago

Check for leaks in the intake/boost piping and CAC and for a turbo or actuator problem. Any other faults logging in the ECM?

Ask Your Own Medium and Heavy Trucks Question
Technician: Daniel Wilson,
 replied 26 days ago

Hi, Did you get this resolved? I see this is still open. Please take a moment to rate as that is how the site credits my time helping on the site or let me know if you need more help. 5 star and bonuses are always greatly appreciated. It's been a pleasure working with you on this.

Ask Your Own Medium and Heavy Trucks Question
Was this answer helpful?
Ask Daniel Wilson Your Own Question
Daniel Wilson
Daniel Wilson
Daniel Wilson
Category: Medium and Heavy Trucks
Satisfied Customers: 6,196
6,196 Satisfied Customers
Experience: Owner at DJ Wilson

Daniel Wilson is online now

A new question is answered every 9 seconds

How JustAnswer works:

  • Ask an ExpertExperts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional AnswerVia email, text message, or notification as you wait on our site. Ask follow up questions if you need to.
  • 100% Satisfaction GuaranteeRate the answer you receive.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

He answered my question promptly and gave me accurate, detailed information. If all of your experts are half as good, you have a great thing going here.

DianeDallas, TX

< Previous | Next >

Meet the Experts:

Daniel Wilson

Daniel Wilson

6,196 satisfied customers

Owner at DJ Wilson

Cat Man

Cat Man

Cat Engine Expert

4,247 satisfied customers

I am ASE Master Truck Certified.

Wayne

Wayne

Journeyman

2,640 satisfied customers

worked on, Gmc, Macks, Freight liner,Mercedes Benz,,Ford, sterling

Jeremy

Jeremy

Certified Truck/Bus Technician

2,019 satisfied customers

ASE Med/HD Truck Technician, NATEF Diesel Engines and Electrical/Electronics Technician, EPA 608/609 HVAC Certified, Steering/Suspension and ABS/Brakes Technician

cumminsdr

cumminsdr

Mechanic

1,225 satisfied customers

All types of Cummins applications

Curtis B.

Curtis B.

Technician

813 satisfied customers

Technician turned service manager on multiple lines of trucks and engines, used in industry.

dieseldan55

dieseldan55

Contractor

74 satisfied customers

Road Service mechanic for Volvo Construction.

< Previous | Next >

Related Medium and Heavy Trucks Questions
I have a 3406e there seems to be a ticking noise in the top
i have a 3406e there seems to be a ticking noise in the top end of my motor. it is a 1lw motor. It doesnt do it all the time i first noticed it under a load. the other day i let it idle in the yard to… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,247 satisfied customers
I have low HP caterpillar 3406e(2ws08414) with a
I have low HP caterpillar 3406e(2ws08414) with a stock(###) ###-####camshaft. One of my injector lobes is starting to get worn down. I ordered a replacement camshaft through YNG LLC. They sent me(###)… read more
Daniel Wilson
Daniel Wilson
6,196 satisfied customers
Working on a c13 car engine highway truck engine serial kcb
Working on a c13 car engine highway truck engine serial kcb how do I put the trim code files in the ecm I have cat et any way u have a step by step how do this on cat et… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,247 satisfied customers
I got a 2005 m2 business class with electrical problems I
I got a 2005 m2 business class with electrical problems I turn on the right hand blinker on the switch and the left blinker comes on instead of the right … read more
Daniel Wilson
Daniel Wilson
6,196 satisfied customers
Having issues with lift pump on isx cummins. 2007 Pete with
Yes if taken pump off and hooked it to another truck it works fine … read more
Andy3221
Andy3221
truck /coach technician
Vocational, Technical or Trade Scho
222 satisfied customers
Have a freightliner columbia with an icu 140 code, Columbia
Trying to, checked the power and ground connections,driver says sometimes the truck wont start,and the oil pressure gauge isnt reading anything, but had it hooked to a computer and it reads oil psi there not sure if all is related to the icu 140 code,also installed a new ignition switch hoping that was the prob with gauges and not start … read more
Wayne
Wayne
Journeyman
Vocational, Technical or Trade Scho
2,640 satisfied customers
Dash lamps flashing on/off cat et cannot connect to ecm but
dash lamps flashing on/off cat et cannot connect to ecm but detects it. no start … read more
Daniel Wilson
Daniel Wilson
6,196 satisfied customers
Can I load a calibration AV10052.51 to and engine serial #
can I load a calibration AV10052.51 to and engine serial #(###) ###-####that has a AV10044.51 calibration both have same cpl 2733 … read more
cumminsdr
cumminsdr
Mechanic
High School or GED
1,225 satisfied customers
I have a cat c15 twin turbo mxs engine trying to adjust
i have a cat c15 twin turbo mxs engine trying to adjust valves … read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,247 satisfied customers
How many hrs until a C9 should be rebuilt under normal
how many hrs until a C9 should be rebuilt under normal operating conditions and normal maintanance … read more
Wayne
Wayne
Journeyman
Vocational, Technical or Trade Scho
2,640 satisfied customers
The sistem go out by pressure. NDA94NNOCMO. R22 serie gau
I will try to check the solenide valve y I let you now letter… read more
Wayne
Wayne
Journeyman
Vocational, Technical or Trade Scho
2,640 satisfied customers
2006 Freightliner Classic Headlights will not dim. They stay
2006 Freightliner Classic Headlights will not dim. They stay on bright continuously. I've tested the dimmer micro switch in the Grote blinker and it works. Any ideas or wiring diagrams?… read more
Andy3221
Andy3221
truck /coach technician
Vocational, Technical or Trade Scho
222 satisfied customers
2007 freightliner columbia, cat 15, motor is not working,
2007 freightliner columbia, cat 15, bunk motor is not working, there is no power at b fuse box, close to driver side, can any body help me… read more
Jeremy
Jeremy
Certified Truck/Bus Technician
Vocational, Technical or Trade School
2,019 satisfied customers
I have a 2016 m2 freightliner with a 6.7 cummins that needs
i have a 2016 m2 freightliner with a 6.7 cummins that needs a block due to vehicle collision. ESN is 58589558. this is a DEF engine. i have located an engine core ESN is 73060509. this is not a DEF en… read more
cumminsdr
cumminsdr
Mechanic
High School or GED
1,225 satisfied customers
I haved a 2013 Mack with a 10.8 MP7 motor with active fault
I haved a 2013 Mack with a 10.8 MP7 motor with active fault code PSID 46 FMI 0, can you help with this?… read more
Jeremy
Jeremy
Certified Truck/Bus Technician
Vocational, Technical or Trade School
2,019 satisfied customers
2010 isuzu npr 5.2 jalc4w161b7000654 any why to disconnect
2010 isuzu npr 5.2 jalc4w161b7000654 any why to disconnect Glow plug circuit I have broken glow plug? on cold start it puts check engine light on .… read more
Andy3221
Andy3221
truck /coach technician
Vocational, Technical or Trade Scho
222 satisfied customers
Have a 02 w 900 with a c15 only has about 20 lbs of boost. I
hello hi have a 02 w 900 with a c15 only has about 20 lbs of boost. I have changed the air to air it was leaking, new hoses , new barometric sensor, new cam and crank sensor , new injectors , new turb… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,247 satisfied customers
I started my d4G dozer after it had not been run for a
I started my d4G dozer after it had not been run for a couple of weeks. The ECM light came on. The machine will move in the lowest speed only. The ECM light is lit on both the dash and the fuse panel.… read more
catmastertech
catmastertech
Field service technician
Vocational, Technical or Trade Scho
1,287 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x