Medium and Heavy Trucks

Have truck repair questions? Ask an Expert

Connect one-on-one with {0} who will answer your question

I have a semi Volvo 2012 D13 Question. D13 h 475. Has check…

Customer Question
I have a semi...

I have a semi Volvo 2012 D13 Question

Mechanic's Assistant: What is the model of your '12 Volvo?

D13 h 475

Mechanic's Assistant: Are you fixing your vehicle yourself? What have you tried so far?

Yes has check codes

Mechanic's Assistant: Just to clarify, what's the exact code? And have you tried to reset it?

SPN 5394FM1 OTHER IS SPN 4094 FM1 CANNOT RESET

Mechanic's Assistant: Anything else you want the mechanic to know before I connect you?

I am trying to park regen and it states Conditions not met check ATS STATUS MANUAL THEN I DO THIS. EVERYTHING IS CHECKED OK EXCEPT FOR TEMPORARY LOCKOUT CHECK. MECHANIC REPLACED COUPLE SENSORS AND CLEARED CODES 200 MILES LATER TRACTOR HAS SAME ISSUES..

Submitted: 4 years ago.Category: Medium and Heavy Trucks
Show More
Show Less
Ask Your Own Medium and Heavy Trucks Question
Answered in 4 hours by:
12/24/2017
Technician: Jeremy, Certified Truck/Bus Technician replied 4 years ago
Jeremy
Jeremy, Certified Truck/Bus Technician
Category: Medium and Heavy Trucks
Satisfied Customers: 4,370
Experience: ASE Med/HD Truck Technician, NATEF Diesel Engines and Electrical/Electronics Technician, Network Engineer specializing in CAN faults, Aftertertreatment, and vehicle communications
Verified

My name is ***** ***** I will assist you with your question today.

I'm an independent contractor and I don't get paid until a rating has been made.

We can go back and forth as needed to help resolve the issue you are having. Follow ups are free after ratings, so rate in confidence!

You might have 1 of a few issues going on.

You are not getting high enough temps on the regen meaning the turbo isn't pushing the proper amount of pressure it should be (the computer needs to run and see that temps are getting to 600 on their own, then the air valve goes to open for the doser, then the temps gradually climb to 1000 degrees). If this is not being seen, then there is an issue with the turbo.

2nd possible is you are getting faceplugging at the DPF DOC which is making the truck think there is not enough pressure getting to the regen system. Watch the differential pressure and if you see it start climbing to the 20's, then you are good. Less than that, pull the exhaust pipe off the entrance to the DOC and clean the screen out. There is a screen there that catches large soot prior to the DPF filter.

3rd possible is you have crystallizing at the SCR system. Use the computer and select the "crystal sub" regen and let that run. That shuts off the metering valve and lets the regen burn out the DEF build up in the SCR system that build up will cause the truck to have good heat at the DPF, but poor heat at the SCR as well as low pressure at the SCR versus the DPF. You will see a 5 psi difference and when you see that, the SCR has crystallized DEF in it.

Lastly is a ash filled DPF and the DPF filter needs to be pulled off and cleaned/baked. Then put back on. If that was done within the last 20k miles, then ignore this one, unless you had an issue with oil consumption indicating you are burning oil which will ash load the DPF filter very early.

These are all the issues I have seen when those codes return with the work you stated have already been done to the truck.

_______________________________________________________________________________

You want a 5 star service and I want to provide a 5 star service. Please consider that I don't know your skill level as well as I can't see, touch, smell, hear the vehicle/machine in question. Please provide as much detail as possible and I will provide as much back.

Once an answer is provided, you should see a rating screen. Please rate my personal service to you. The ratings are my personal feedback, they are not the site feedback.

Thank you for allowing me to assist you through Just Answer!

Jeremy

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 4 years ago
How can we check to see if the turbo is bad ?
How can we check to see if the temperatures are 600 - 1000 ?
Technician: Jeremy, Certified Truck/Bus Technician replied 4 years ago

You use the PTT software on the laptop. It will show you the temps of what the regen is doing. You can then look at the turbo sensors and it will show you the position of the vanes (30%) and the speed (12k rpm), and the pressure (22 psi) with the EGR at less than 15% flow. Then the dpf should be in the 20s on the differential pressure. If you are not seeing that, then the turbo actuator is not working properly.

Ask Your Own Medium and Heavy Trucks Question
Technician: Jeremy, Certified Truck/Bus Technician replied 4 years ago

I see you viewed this and this is still showing as an open question due to no positive (3 stars or more) rating.

Did you still need assistance with this?

Do you need more time to resolve the issue?

Ask Your Own Medium and Heavy Trucks Question
Was this answer helpful?

How JustAnswer works

step-image
Describe your issueThe assistant will guide you
step-image
Chat 1:1 with a technicianLicensed Experts are available 24/7
step-image
100% satisfaction guaranteeGet all the answers you need
Ask Jeremy Your Own Question
Jeremy
Jeremy
Jeremy, Certified Truck/Bus Technician
Category: Medium and Heavy Trucks
Satisfied Customers: 4,370
4,370 Satisfied Customers
Experience: ASE Med/HD Truck Technician, NATEF Diesel Engines and Electrical/Electronics Technician, Network Engineer specializing in CAN faults, Aftertertreatment, and vehicle communications

Jeremy is online now

Related Medium and Heavy Trucks Questions
I have a 2013 volvo 780 with a D13 that keeps requesting
I have a 2013 volvo 780 with a D13 that keeps requesting parked Regen (not regening while driving) code that shows active after it regens SA 0 SPN 5394 FMI 17, volvo replaced the 7th injector but did … read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
581 satisfied customers
Temporary lockout check. I ned guidance to remove temporary
temporary lockout check JA: What's the make, model, and year of your car? Customer: i ned guidance to remove temporary lockout JA: What's the approximate mileage on your car? Customer: 629597 JA: Is t… read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
581 satisfied customers
Temporary lockout code. Not. Volvo d13 2017. Neutral check.
temporary lockout code JA: Have you seen this error before with the same vehicle? Customer: not JA: What's the make, model, and year of your car? Customer: volvo d13 2017 JA: Is there anything else th… read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
581 satisfied customers
I got code 4094 fmi1 Volvo d13, before I changed doser
Hi there! I got code 4094 fmi1 Volvo d13, before I changed doser valve, def line between def pump and def doser valve, new 7th injector wat leso need to do with that? Thanks … read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
581 satisfied customers
I got lights on and find there is issue with temporary
I got lights on and find there is issue with temporary lockout how can I fix it this is 2017 Volvo VNL … read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
581 satisfied customers
Parked Regen Status not met. 2015 Volvo D13. I am on side
Parked Regen Status not met JA: What's the make/model/year of your truck? Engine type? Customer: 2015 Volvo D13 JA: Are you fixing your truck yourself? What have you tried so far? Customer: I am on si… read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
581 satisfied customers
I have 4 codes in my Volvo truck with D13 Engine. Yesterday
Hello I have 4 codes in my Volvo truck with D13 Engine . Yesterday We have snow and temp was around -20 while driving I have yellow check engine light and these 3 code 1- SA 0 SPN 5246 FMI 16 2- SA 0 … read more
Andy
Andy
truck /coach technician
Vocational, Technical or Trade School
214 satisfied customers
I have a volvo 2012 d13. regen needed, however when i go to
i have a volvo 2012 d13. regen needed, however when i go to initiate a regen the truck says check ats status? … read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
581 satisfied customers
Volvo truck showing code SA 16 dtc p24af00. Just need to
No but might depending on how much work is involved … read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
581 satisfied customers
2012 Volvo VNL670. Yellow check is on, SCR derate in 60
2012 Volvo VNL670. Yellow check is on, SCR derate in 60 minutes. Park regen conditions not met check ATS... ATS says temporary lockout … read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
581 satisfied customers
I have check engine light on temp lock out I've been driving
I have check engine light on temp lock out I've been driving with speed sensor unplugged from transmission trying get reset no luck what should I do … read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
581 satisfied customers
I need to REGEN but my ATS status has a temporary lock 2011
I need to REGEN but my ATS status has a temporary lock 2011 Volvo d13 … read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
581 satisfied customers
2014 volvo vnl 670 d13 will not regen temporary lockout
2014 volvo vnl 670 d13 will not regen temporary lockout showing check on ats status … read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
581 satisfied customers
2011 Volvo 780 D13. Regen needed", temporary lockout so
regen needed", temporary lockout so regen cannot complete. How do i clear temporary lockout and run parked regen? Need to complete both tasks. … read more
Daniel Wilson
Daniel Wilson
Auto Mechanics 1&2/diesel mech
6,062 satisfied customers
I have 2012 Volvo with an isx. A code just came up Spn 3226
I have 2012 Volvo with an isx. A code just came up Spn 3226 fmi 10 Can someone help figure out what this means?… read more
FIX-IT
FIX-IT
Comercial transport technician
Vocational, Technical or Trade Scho
829 satisfied customers
I have a 2012 volvo 670 d13 engine. And it shows ats status
I have a 2012 volvo 670 d13 engine. And it shows ats status temporary lockout. How can i fix this ? … read more
Daniel Wilson
Daniel Wilson
Auto Mechanics 1&2/diesel mech
6,062 satisfied customers
I have a problem with my volvo d13 2012.... temperature gets
Customer: hello, i have a problem with my volvo d13 2012.... temperature gets high when do regen.. come up with code 4094,5246 … read more
Daniel Wilson
Daniel Wilson
Auto Mechanics 1&2/diesel mech
6,062 satisfied customers
2012 intl Durastar Maxx force 466 ,7.6l, regen light wontt
2012 int'l Durastar Maxx force 466 ,7.6l, regen light wont't clear after regen process. codes present are SPN 3919-Fm1-0, SPN931- FM1-11, SPN 165 FM1-12, SPN630 FM1-13, SPn 639 FM1-9, SPN 597 FM1-2, S… read more
Andy
Andy
truck /coach technician
Vocational, Technical or Trade School
214 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

He answered my question promptly and gave me accurate, detailed information. If all of your experts are half as good, you have a great thing going here.

DianeDallas, TX

< Previous | Next >

Meet the Experts:

Daniel Wilson

Daniel Wilson

6,062 satisfied customers

Owner at DJ Wilson

Cat Man

Cat Man

Cat Engine Expert

5,353 satisfied customers

I am ASE Master Truck Certified.

Wayne

Wayne

Journeyman

5,115 satisfied customers

worked on, Gmc, Macks, Freight liner,Mercedes Benz,,Ford, sterling

Jeremy

Jeremy

Certified Truck/Bus Technician

4,370 satisfied customers

ASE Med/HD Truck Technician, NATEF Diesel Engines and Electrical/Electronics Technician, Network Engineer specializing in CAN faults, Aftertertreatment, and vehicle communications

Curtis B.

Curtis B.

Technician

1,947 satisfied customers

Technician turned service manager on multiple lines of trucks and engines, used in industry.

cumminsdr

cumminsdr

Mechanic

1,886 satisfied customers

All types of Cummins applications

Chris (aka-Moose)

Chris (aka-Moose)

Technician

641 satisfied customers

24 years of experience diagnosing & repairing

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x