I have a 1998 Freightliner FL70 with a cat 3126, cel on, no…

Customer Question
I have a 1998...

I have a 1998 Freightliner FL70 with a cat 3126, cel on, no power, stalled out. Did restart and dron

Mechanic's Assistant: What is the complete model and serial number of your machine?

1998 Freightliner FL 70, Cat 3126. Codes are 15 17 39 and 71

Mechanic's Assistant: Are you fixing this yourself? What have you tried so far?

Yes

Mechanic's Assistant: Anything else you want the equipment mechanic to know before I connect you?

Last month it did not start found oil pressure sensor bad. Replaced it and started. No problems until now

Submitted: 5 years ago.Category: Medium and Heavy Trucks
Show More
Show Less
Ask Your Own Medium and Heavy Trucks Question
Answered in 6 minutes by:
10/2/2017
Technician: Cat Man, Cat Engine Expert replied 5 years ago
Cat Man
Cat Man, Cat Engine Expert
Category: Medium and Heavy Trucks
Satisfied Customers: 10,344
Experience: I am ASE Master Truck Certified.
Verified
Thanks for asking your question. I will try and help you out.Codea 39 is defined as an Injection Actuation Pressure System fault. Code 15 is defined as injection actuation pressure erratic. I see this a lot on these engines. These code indicates the ECM is not seeing the correct Injection Actuation Pressure. These codes and problem is caused by several things.The first and most common is a faulty Injection Actuation Pressure Control Valve. Also known as an IAPCV. It has two wires connected to it and is screwed into the High pressure HEUI pump.
Second is a Faulty HEUI pump. To test a high pressure 5000 psi gauge is needed to connect to the outlet of the HEUI pump.
Third is a faulty IAP sensor
And lastly is a leaking injector.Code 17 is defined as excessive actuation pressure. This can only be caused by a bad iapcv or Heui pump.Code 71 is a low power to ecm code. I would not worry about this one. It's on most of these engines when I see them.Please reply back if you need more help or have more questions. I am happy to assist.
Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 5 years ago
I replaced the GP-Solenoid a month ago. The nut on the back side fell off. I replaced sensor and it started and ran for a month.I did not clear codes. The other day when the cel came on it lost power, made it back to shop. Now it won't start.
Technician: Cat Man, Cat Engine Expert replied 5 years ago
Thanks for the information.
So the engine is a cracked and no start ? And the yellow check engine light comes on when the key is turned to the on position?
Ask Your Own Medium and Heavy Trucks Question
Technician: Cat Man, Cat Engine Expert replied 5 years ago
Thanks for the information.Since the yellow check engine light comes on, this indicates the engine ECM is receiving power and functioning. There are several things that can cause a crank no start on this engine.The first is a low or no fuel pressure condition. The engine needs at least 25 psi to start. If it is low, the injectors will not get filled and it will not start. If the engine has a hand priming pump, and it gets stiff when operating it, the engine has enough pressure to start. If there is no hand priming pump, I would connect a psi gauge and measure the pressure. If the pressure is low, I would change the fuel filters first if you haven’t already. If it is still low, I would suspect a failed fuel pressure regulator on the back of the head or a weak fuel transfer pump. The pump is located on the back of the HEUI pump.Second is a low injection actuation pressure. This is the high pressure oil system that activates the injectors. The engine needs at least 870 psi to start. If it is low, you have either a failed Injection actuation pressure control valve in the HEUI pump, a weak HEUI pump, a high pressure oil leak at an injector, or a faulty Injection actuation pressure sensor. To test the sensor, just unplug it. If the engine starts, the sensor is bad. It has 3 wires and is located on top of the engine near the front and screwed into the head.Third is a failed engine speed timing sensor. Your engine has two. They are located on the driver’s side of the engine on the back of the engines front cover under the HEUI pump. The bottom sensor is the primary start sensor. If it has failed, the engine will be hard to start. The top one is the primary run sensor. They come as a pair.Next is low battery voltage to the ECM while cranking. The ECM must have at least 7.5 volts DC to operate. I have seen weak batteries or a poor connection cause low voltage. You could have a poor connection at the batteries or starter.Next is a faulty engine ECM. The ECM has an injector driver module inside. This is what powers the injectors. If it fails, the ECM will log injector codes for all the injectors.Lastly are worn injectors. Over time the injectors can wear if they have a lot of hours on them. To verify, I like to check AC to the injectors while cranking. You should have between 20-40 AC while cranking. If you do, and you have good fuel pressure, the injectors are worn.Most often when these things are happening there will be diagnostic codes in the ECM. If your engine has cruise control switches, you can pull the codes. If you have never done this, let me know. I can get you the procedure.Please reply back if you need more help or have more questions. I am happy to assist.
Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 5 years ago
I gave you all the codes 15, 17, 39, 71.
Technician: Cat Man, Cat Engine Expert replied 5 years ago
I know. Thanks for the information. I suspect you have a faulty iapcv or Heui pump. I see this a lot.
Please reply back if you need more help or have more questions. I am happy to assist.
Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 5 years ago
How would I test these 2 components
Technician: Cat Man, Cat Engine Expert replied 5 years ago
To test you must connect a 5000 psi gauge to the outlet of the Heui pump. While cranking. The Heui must make a minimum of 4000 psi steady. If it does not. You change the iapcv and retest. If it still below 4000. The Heui pump is bad.
Please reply back if you need more help or have more questions. I am happy to assist.
Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 5 years ago
Like I said before I replaced the iapcv a month ago. Part #(###) ###-#### It started and ran fine after I replaced it,
Technician: Cat Man, Cat Engine Expert replied 5 years ago
I see. You may have a bad Heui then. I have seen new iapcv go bad soon after replacing but not often.
Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 5 years ago
Kind of a expensive procedure if iapcv is not bad. Is there a way to test the iapcv out of pump.
Technician: Cat Man, Cat Engine Expert replied 5 years ago
Unfortunately not. Sorry. I wish there was a way.
Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 5 years ago
This test gauge, is it the same for testing hydraulic pump pressure.
Technician: Cat Man, Cat Engine Expert replied 5 years ago
it is.
Ask Your Own Medium and Heavy Trucks Question
Technician: Cat Man, Cat Engine Expert replied 5 years ago
Hey. I just wanted to see how things were going. Please let me know if you need more help. I am happy to assist. If my information was helpful, please leave a good or higher rating so that I receive credit. Thanks.
Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 5 years ago
Waiting for my test gauges to arrive.
Technician: Cat Man, Cat Engine Expert replied 5 years ago
10-4
Ask Your Own Medium and Heavy Trucks Question
Was this answer helpful?

How JustAnswer works

step-image
Describe your issueThe assistant will guide you
step-image
Chat 1:1 with a technicianLicensed Experts are available 24/7
step-image
100% satisfaction guaranteeGet all the answers you need
Ask Cat Man Your Own Question
Cat Man
Cat Man
Cat Man, Cat Engine Expert
Category: Medium and Heavy Trucks
Satisfied Customers: 10,344
10,344 Satisfied Customers
Experience: I am ASE Master Truck Certified.

Cat Man is online now

Related Medium and Heavy Trucks Questions
I have a 1998 freightliner fl70, came in with a actuation
I have a 1998 freightliner fl70, came in with a actuation pressure sensor issue we replaced the sensor with an OEM cat sensor we then ran the unit and still has the issue did a cylinder cut out and cy… read more
Nich1019
Nich1019
Diesel Technician
Vocational, Technical or Trade School
80 satisfied customers
I have a 2002 Freightliner FL70 with a Cat 3126 CKM18004.
I have a 2002 Freightliner FL70 with a Cat 3126 CKM18004. The truck does run but I have no RPM, Speedometer, Oil Pressure, Water Temp and "No Eng" showing on the dash display. I have an ECU 128 SID 25… read more
Wayne
Wayne
Journeyman
Vocational, Technical or Trade Scho
5,115 satisfied customers
2002 Freightliner FL70 C7 3126 Cat Motor. First, over a year
2002 Freightliner FL70 C7 3126 Cat Motor . First, over a year ago, all dash lights and instrumentation including speedo just stopped working. Check engine light and fuel gauge do work. This truck has … read more
Daniel Wilson
Daniel Wilson
Auto Mechanics 1&2/diesel mech
6,062 satisfied customers
1995 FL-70 FREIGHTLINER. HAS REVERSE BUT NO FORWARD GEARS.
1995 FL-70 FREIGHTLINER. HAS REVERSE BUT NO FORWARD GEARS. READER SAID BAD OUTPUT SPEED SENSOR AND ENGINE SPEED SENSOR BAD. REPLACED BOTH STILL NO GO. … read more
Daniel Wilson
Daniel Wilson
Auto Mechanics 1&2/diesel mech
6,062 satisfied customers
I have an 2000 Freightliner FL70 with a cat 3126. When I do
Good day, I have an 2000 Freightliner FL70 with a cat 3126. When I do an air brake test a buzzer (I was told low oil pressure) stays on when I shut the engine down and turn the key back to on. I am ta… read more
Wayne
Wayne
Journeyman
Vocational, Technical or Trade Scho
5,115 satisfied customers
I have 2000 FL 70 with a cat 3126 and Eaton autoshift tCNNhe
Hello I have 2000 FL 70 with a cat 3126 and Eaton autoshift tCNNhe truck only has 60,000 miles I bought the truck a year ago and have problems with the transmission. Had it towed into Freightliner and… read more
Mike Mcmillan
Mike Mcmillan
Triage Tech/Shop Foreman
Associates
604 satisfied customers
1998 FL70 Freightliner with an 8.3 Cummins motor. It will
1998 FL70 Freightliner with an 8.3 Cummins motor. It will run and then the engine shut off light will come on and the motor will shut off. It will restart, but in like five minutes it will do it again… read more
cumminsdr
cumminsdr
Mechanic
High School or GED
1,886 satisfied customers
I have a 99 3126b that after reaching operating operating
I have a 99 3126b that after reaching operating operating temp, with good oil psi, after sitting 15 min. cranks hard to restart. I've replaced the low psi oil pump (Got great psi after that), fuel fil… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
10,344 satisfied customers
3126 Catapillar engine will start and idle fine When you try
3126 Catapillar engine will start and idle fine When you try to move truck engine has Power for a few seconds then no power and will stall but will start right back up Does not matter if engine is col… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
10,344 satisfied customers
I have a 2001 cat 3126 in a fl70 box truck with 276,000
i have a 2001 cat 3126 in a fl70 box truck with 276,000 miles the flash codes are 39 15 49 12 61 69. It starts up then the engine protect light comes on and shuts the motor down. I cleaned all connect… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
10,344 satisfied customers
I have a 2001 Freightliner FL70 with a CAT 3126 engine. It
I have a 2001 Freightliner FL70 with a CAT 3126 engine. It has two fault codes stored. 91 and 5. Is this a serious issue. I cannot start the truck right now as I am waiting for a new injector pressure… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
10,344 satisfied customers
1997 Freightliner FL70 with 3126 Cat Engine and Automatic
1997 Freightliner FL70 with 3126 Cat Engine and Automatic Transmission.The Water\Oil light is coming on intermittently along with a buzzer. Can someone help me trouble shoot this? I don't want to arbi… read more
FIX-IT
FIX-IT
Comercial transport technician
Vocational, Technical or Trade Scho
829 satisfied customers
2002 Freightliner FL60 bucket truck with a Cat 3126 engine.
2002 Freightliner FL60 bucket truck with a Cat 3126 engine. Engine light comes on while driving, then engine shuts off. Sometimes it will run until I come to a stop and then shuts off (almost like sto… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
10,344 satisfied customers
1998 freightliner FL70 truck,cat engine 3126 bin sitting about
1998 freightliner FL70 truck,cat engine 3126 bin sitting about 9 months, put new batteries in it new fuel filters cranks over fine,wont start. spray starting fluid it fires but wont run,i was thinking… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
10,344 satisfied customers
Buddy, I am looking to get into hotshot loads with goose neck
Buddy, I am looking to get into hotshot loads with goose neck I was going to buy a 1 ton dodge until I started looking at some of the Fl 60 an 70s and the cost for used is a lot less. question pulling… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
10,344 satisfied customers
I AM TRYING TO FIND A WIRING HARNESS FOR 2001 FREIGHTLINER
I AM TRYING TO FIND A WIRING HARNESS FOR 2001 FREIGHTLINER FL70 VIN. NO. IS 1FV6HJBBX1HG77185. THE FREIGHTLINER wiring harness no. is A06-33563-002. I cannot seem to find a new or good used one.I am w… read more
Clayton
Clayton
Technician
Vocational, Technical or Trade Scho
627 satisfied customers
I have a cat 3126 in a 2001 fl70 farm truck. came in with a
I have a cat 3126 in a 2001 fl70 farm truck. came in with a load last night, no power. Fuel filters have 200 miles, but that's what it acts like. Flash code 39 Harlan… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
10,344 satisfied customers
I have a FL70 3126 Cat. Problem started out to be a surge at
I have a FL70 3126 Cat. Problem started out to be a surge at road speed ( goes off power and comes on strong). WOT seems ok. Now it will surge and if I stop on an exit ramp, idle surge is bad and stal… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
10,344 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

He answered my question promptly and gave me accurate, detailed information. If all of your experts are half as good, you have a great thing going here.

DianeDallas, TX

< Previous | Next >

Meet the Experts:

Daniel Wilson

Daniel Wilson

6,062 satisfied customers

Owner at DJ Wilson

Cat Man

Cat Man

Cat Engine Expert

10,344 satisfied customers

I am ASE Master Truck Certified.

Wayne

Wayne

Journeyman

5,115 satisfied customers

worked on, Gmc, Macks, Freight liner,Mercedes Benz,,Ford, sterling

Jeremy

Jeremy

Certified Truck/Bus Technician

2,756 satisfied customers

ASE Med/HD Truck Technician, NATEF Diesel Engines and Electrical/Electronics Technician, Network Engineer specializing in CAN faults, Aftertertreatment, and vehicle communications

Curtis B.

Curtis B.

Technician

1,947 satisfied customers

Technician turned service manager on multiple lines of trucks and engines, used in industry.

cumminsdr

cumminsdr

Mechanic

1,886 satisfied customers

All types of Cummins applications

Chris (aka-Moose)

Chris (aka-Moose)

Technician

641 satisfied customers

24 years of experience diagnosing & repairing

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x