2012 international workstar with maxxforce engine has no codes but 4 and 6 are missing with excessive smoke smells like raw fuel out exhaust. Cant tell much of difference when cut them two cylinders out. Both had good compression.
Submitted: 8 months ago.Category: Medium and Heavy Trucks
Show More
Show Less
Ask Your Own Medium and Heavy Trucks Question
Answered in 13 minutes by:
9/18/2017
Technician: Andy, Truck Diagnostic Technician replied 8 months ago
Andy
Andy, Truck Diagnostic Technician
Category: Medium and Heavy Trucks
Satisfied Customers: 1,877
Experience: International and Isuzu trucks , International, Maxxforce, Cummins and Isuzu engines, Diagnostic and electrical troubleshooting specialist , Hvac and truck /trailer refrigeration troubleshooter
Verified
Hi there . My name is Andy. Have you done an injector buzz test ? Using servicemaxx?
Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
have done a buzz test. Had good compression so replaced injectors and same thing.
Customer reply replied 8 months ago
No codes active either.
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Sorry ... technical issues at my end . I'm back !

Ask Your Own Medium and Heavy Trucks Question
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

So we replaced the injectors , and now we do a buzz test , and all sounds fine , correct ? They all buzz the same ?

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
sir. egr cooler was busted so replaced it first and now have this issue
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Ok and what about fuel pressure ? What is the fuel pressure reading on service maxx ?

Ask Your Own Medium and Heavy Trucks Question
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

If this has the electric fuel pump , you should be seeing a steady 75 psi when engine is running .

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
showed good let me check with manual gauge
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

manual gauge on the rail will be 90 psi . while engine is running .

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
100 psi
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Ok . Thanks for that . Is there still a definite miss in the engine when running ? Since we just replaced injectors , and had to pull the oil rail off to do so , we need to run the engine at a higher idle for a good 10 min til it gets to temp and let it clear up . Then a good*****test while pushing it on hills may be required as well to help get all the trapped air out of the high pressure injection system . Then retest for the concern .

Ask Your Own Medium and Heavy Trucks Question
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Also , if you have the newer versions of servicemaxx , you should preform a COEM injector reset on the injectors that were replaced , followed by an ICP adaptation reset . These procedures are done when parts were replaced in the high pressure system .

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
did run and drive and 4 and 6 dont make any difference when cut them out. Alot of white smoke smells like raw fuel out exhaust.
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Do you have servicemaxx ? And if you do , can you perform a COEM reset under the procedures tab ?

Ask Your Own Medium and Heavy Trucks Question
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

This procedure is for the injectors that have just been installed . It precisely sets them up where they need to be .

Ask Your Own Medium and Heavy Trucks Question
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

We no longer use the injector disable tests as they are not very acurate or a trustworthy test . We connect a cylinder performance analyser (CPA tester ) to diagnose the cylinders individually . This gives better and more acurate results . Can I have the last 8 digits of the vin number please ?

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
Do not have service maxx
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Also , can you confirm that ICP desired and injection control pressure are always close to the same throughout all ranges ?

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
Let me confirm
Customer reply replied 8 months ago
BJ437693
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

ICP changes with engine load and accel pedal demand , but actual ICP should always follow desired ICP and stay with 150 psi + or - of desired ICP . This system goes as high as 4500 Psi when fully loaded

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
sir icp pressure confirmed. removed egr valve and is wet.
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Egr valve is all wet from the EGR cooler . You mentionned it has been replaced correct ?

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
Dry it up start it and wet again. Have already drove it after egr coolant replacement and ran good. Thought was all burned up because didnt smoke anymore. Than all the sudden boom started missing and smokeing.
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Wet again of coolant ? Have you noticed the coolant level dropping in the surge tank ? Do you know if this is coolant ? Can you try a freeze stip on the fluid to see if it is coolant again or if it is fuel ?

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
Hard to tell if coolant or fuel with all the soot mixed in but i can try it.
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Is the coolant level dropping ?

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
Did not notice it dropping and didnt test im about to remove intake tube off egr cooler and see what comes out
Customer reply replied 8 months ago
tested as bad in freeze stick
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Does it show a freeze protection ?

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
Showed unsafe.
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

I don't want you to check the freeze protection of the coolant in the surge tank . I need you to try and scoop some of the wet stuff at the egr valve and put it in a clean styrofoam cup or something , then add a lfew spoons of water to it , stir it together and then check that mix for freeze protection . If there is any freeze protection showing , it is because there is coolant running through there

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
u did that and tested unsafe. than got some from surge tank and tested good. Remove intake tube off egr cooler running behind head. started it and have diesel blowing out of egr cooler?
Customer reply replied 8 months ago
Let me catch some that fluid out of there and test ot
Customer reply replied 8 months ago
Let me catch some that fluid out of there and test it
Customer reply replied 8 months ago
Its diesel for sure.
Customer reply replied 8 months ago
Removed temp sensor on mlexhausr manifold and was dry.
Customer reply replied 8 months ago
Wouldnt mix with water and desintagrated styrofoam cup
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Ok so a fuel problem . Do we have air in the fuel possibly at the fuel rail ?

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
Not sure. How do i check that exactly
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

when checking fuel pressure at the rail with a manual gauge , your pressure gauge line should be setup with a t-block that has a shutoff valve on one port with a clear line on the other side of the shutoff valve . So when checking fuel pressure , you can turn the shutoff valve on and let fuel run out of the clear line into a bucket to see if there is any air in the fuel coming out .

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
What am i checking here exactly? A cracked head maybe? How else can fuel get in the exhaust like that unless one of the new injectors is stuck open? Where do i hook up to check rail pressure? I had it on test port on fuel filter housing
Customer reply replied 8 months ago
Should i pull turbos and see how much fuels in it.
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

No... there is a test port right on the fuel rail n the left side of the engine . It is a valve stem looking fitting . It should be right behind the front cover and above the high pressure oil pump .

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
90 to 100 psi on rail all the time with no air bubbles. open valve and a couple small bubbles than clears up no bubbles
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

I will show you a pic

Ask Your Own Medium and Heavy Trucks Question
Technician: Andy, Truck Diagnostic Technician replied 8 months ago
Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
i have already hooked up a gauge with valve just like that. Messaged you results above buddy
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Have you checked for air coming out with fuel while running at idle and at high idle no load ?

Ask Your Own Medium and Heavy Trucks Question
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Also , if you connect the egr valve to harness but leave it out , when you turn the key on , does the egr valve cycle open at all momentarily ?

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
sir already did and yes its air firel mixture coming out of egr port. let me check of egr cycles momentarily while plugged in.
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

Is the egr valve stuck open ? It is spring loaded and should default completely closed .

Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
No closed all the way
Customer reply replied 8 months ago
Not stuck open
Customer reply replied 8 months ago
Does not open when plugged in and key on. i open it up ajd it pulls in closed thoughm
Technician: Andy, Truck Diagnostic Technician replied 8 months ago
Okay and what about your intake throttle valve? It should be defaulting open. It is located at the end of the charge air cooler Outlet hose going into the engine
Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
it is default position open
Customer reply replied 8 months ago
Electric set overnight removed injectors number 4 cylinder full of fuel
Customer reply replied 8 months ago
I let*
Customer reply replied 8 months ago
Swapped injectors out with known good ones than the still dumping fuel into cylinders excessive fuel in the exhaust
Customer reply replied 8 months ago
What should I check next I really need a response please and thank you
Customer reply replied 8 months ago
Can I get a flow diagram for the fuel system please sir
Technician: Andy, Truck Diagnostic Technician replied 8 months ago

sorry for the delay but I also work days at the garage . I will look that up for you

Ask Your Own Medium and Heavy Trucks Question
Technician: Andy, Truck Diagnostic Technician replied 8 months ago
Ask Your Own Medium and Heavy Trucks Question
Customer reply replied 8 months ago
Would the check valve cause over fueling. Acts like 4 5 and 6 dont change sound of engine when unplug them. checked ohmed harness and is good.? No codes
Customer reply replied 8 months ago
Smokes real bad still. raw fuel
Customer reply replied 8 months ago
Where is the fuel pressure regulator valve and the check valve?
Was this answer helpful?
Ask Andy Your Own Question
Andy
Andy
Andy, Truck Diagnostic Technician
Category: Medium and Heavy Trucks
Satisfied Customers: 1,877
1,877 Satisfied Customers
Experience: International and Isuzu trucks , International, Maxxforce, Cummins and Isuzu engines, Diagnostic and electrical troubleshooting specialist , Hvac and truck /trailer refrigeration troubleshooter

Andy is online now

A new question is answered every 9 seconds

How JustAnswer works:

  • Ask an ExpertExperts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional AnswerVia email, text message, or notification as you wait on our site. Ask follow up questions if you need to.
  • 100% Satisfaction GuaranteeRate the answer you receive.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

He answered my question promptly and gave me accurate, detailed information. If all of your experts are half as good, you have a great thing going here.

DianeDallas, TX

< Previous | Next >

Meet the Experts:

Daniel Wilson

Daniel Wilson

2,322 satisfied customers

Owner at DJ Wilson

Cat Man

Cat Man

Cat Engine Expert

4,247 satisfied customers

I am ASE Master Truck Certified.

Wayne

Wayne

Journeyman

2,640 satisfied customers

worked on, Gmc, Macks, Freight liner,Mercedes Benz,,Ford, sterling

Jeremy

Jeremy

Certified Truck/Bus Technician

2,019 satisfied customers

ASE Med/HD Truck Technician, NATEF Diesel Engines and Electrical/Electronics Technician, EPA 608/609 HVAC Certified, Steering/Suspension and ABS/Brakes Technician

cumminsdr

cumminsdr

Mechanic

1,225 satisfied customers

All types of Cummins applications

Curtis B.

Curtis B.

Technician

813 satisfied customers

Technician turned service manager on multiple lines of trucks and engines, used in industry.

dieseldan55

dieseldan55

Contractor

74 satisfied customers

Road Service mechanic for Volvo Construction.

< Previous | Next >

Related Medium and Heavy Trucks Questions
Ac comp clutch won t engage. Full of gas, can operate by
Ac comp clutch won t engage. Full of gas, can operate by applying ground to compressor or high pressure switch … read more
Wayne
Wayne
Journeyman
Vocational, Technical or Trade Scho
2,640 satisfied customers
Troubleshooting 1995 isuzu npr. No power to ac compressor.
Troubleshooting 1995 isuzu npr. No power to ac compressor. Fuse okbu do not know where relay is … read more
Andy
Andy
Truck Diagnostic Technician
1,877 satisfied customers
I have a deere 8100 cranks but wont start. Not sure of
not sure of serial number but its a 1997 john deere 8100 … read more
Wayne
Wayne
Journeyman
Vocational, Technical or Trade Scho
2,640 satisfied customers
07 Kenworth with a Cat c15 Wont shut off when I turn key
07 Kenworth with a Cat c15 Wont shut off when I turn key back, Starts Fine and runs perfectly.I replaced the IGN Relay, Same problem. And trucks turns off when I pull relay out… read more
Wayne
Wayne
Journeyman
Vocational, Technical or Trade Scho
2,640 satisfied customers
Need Cummings Specialist 2014 F750 Cummins ISB Active Codes
Need Cummings Specialist 2014 F750 Cummins ISB Active Codes 3563, 2555, 3714 Engine Serial #73664573Unit will not start or act like it even wants to start at this time. Had truck towed to our shop. Th… read more
roy
roy
Associate Degree
3 satisfied customers
Im a drivaway driver... International HX 2019 are usually
international HX 2019 are usually the problem. we have to reinstall the axels when ee get to the location.sometimes they just WONT GO the last inch. these are the double spline axels .they are some problem for many of us ANY TRICKS ? … read more
Andy
Andy
Truck Diagnostic Technician
1,877 satisfied customers
I have a 1997 international 4700 dt466e that is puffing
I have a 1997 international 4700 dt466e that is puffing white smoked out from behind the turbo amongst other places, but a lot of white smoke. The truck is hard to start but when it does white smoke s… read more
Wayne
Wayne
Journeyman
Vocational, Technical or Trade Scho
2,640 satisfied customers
2011 international 4300 with maxxforce, codes spn94 fmi17.
2011 international 4300 with maxxforce, codes spn94 fmi17 … read more
Andy
Andy
Truck Diagnostic Technician
1,877 satisfied customers
Cat man, I have a customer with a c12 cat here, s/n ALS00353
Cat man, I have a customer with a c12 cat here, s/n ALS00353 engine fan running all the time, checked all my inputs to ecm all temp sensor ok, my fan control on et says fan off, and also a/c pressure … read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,247 satisfied customers
I have a isx 870 it keeps shutting down as if you are
I have a isx 870 it keeps shutting down as if you are turning the key off only does is when you are loaded . … read more
Andy
Andy
Truck Diagnostic Technician
1,877 satisfied customers
99 international 9200 semi. No gauges, laptop will not
99 international 9200 semi JA: What is the make/model of your car? Customer: no gauges, laptop will not communicate JA: Are you fixing your vehicle yourself? What have you tried so far? Customer: Yes.… read more
timdieseltech
timdieseltech
diesel tech
Vocational, Technical or Trade School
63 satisfied customers
Does a 2006 freightliner 60 series Detroit have a crank
Does a 2006 freightliner 60 series Detroit have a crank sensor? … read more
timdieseltech
timdieseltech
diesel tech
Vocational, Technical or Trade School
63 satisfied customers
I have a light on the top of my dash that comes one red,
I have a light on the top of my dash that comes one red, with the letters abs in it, that's turned on? … read more
Pete
Pete
Independent Auto Technician
Vocational, Technical or Trade Scho
138 satisfied customers
3 piston is gauled and does not want to knock out on my 3.9
3 piston is gauled and does not want to knock out on my 3.9 cummins, I don't want to damage the rod if I can help it. Do I drill out the top of the piston? … read more
cumminsdr
cumminsdr
Mechanic
High School or GED
1,225 satisfied customers
What are the torque specs for n 14 exhaust manifold.
What are the torque specs for n 14 exhaust manifold … read more
cumminsdr
cumminsdr
Mechanic
High School or GED
1,225 satisfied customers
I have a cat 3126 Marine engine that cranks but does not
Hi I have a cat 3126 Marine engine that cranks but does not start. Serial 3GS02117. I recently replaced injectors and injector cups, injector actuation solenoid, injector pressure sensor and had the c… read more
Cat Man
Cat Man
Cat Engine Expert
Vocational, Technical or Trade Scho
4,247 satisfied customers
471 Massey a lot of vibration, 471 bmo9013, Nothing looking
Nothing looking to buy has vibration does engine have balance shaft … read more
Curtis B.
Curtis B.
Technician
Associate Degree
813 satisfied customers
I need to know how much Freon goes into my 89 Peterbilt 362
I need to know how much Freon goes into my 89 Peterbilt 362 after vacuuming system … read more
spankyjr1
spankyjr1
Retired
Vocational, Technical or Trade Scho
19 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x