HVAC

Have HVAC questions? Ask an HVAC Expert for answers

Ask an Expert,
Get an Answer ASAP!

Related HVAC Questions
I just replaced my carrier control board (ICM275) and wire
I just replaced my carrier control board (ICM275) and wire harness. I go to start my furnace and it Keeps blowing the 3amp (low voltage) fuse. I disconnected the thermostat and tried the direct wire c… read more
HVAC Guru
HVAC Guru
HVAC TECH
19,214 satisfied customers
Nate, our main floor heat stopped working, seeing if there's
Hey Nate, our main floor heat stopped working, seeing if there's anything I can do to troubleshoot it tonight since it's cold outside… read more
Tim H.
Tim H.
Lead building engineer
Vocational, Technical or Trade Scho
3,962 satisfied customers
Guys, Im having a problem with my Goodman GMPN100-4 furnace
Guys, I'm having a problem with my Goodman GMPN100-4 furnace blowing 3amp fuse. First I want to say that I was using this a a gas furnace for years but since decided to change to all electric heat. I … read more
Tim H.
Tim H.
Lead building engineer
Vocational, Technical or Trade Scho
3,962 satisfied customers
I have a Carrier, Infinity System, Thermostat. Last night the
I have a Carrier, Infinity System, Thermostat. Last night the display went off, as if the unit was not receiving power. I pulled the unit off the wall, and tested the wires for voltage. There's power … read more
Theplumber717
Theplumber717
Plumber
Vocational, Technical or Trade Scho
1,264 satisfied customers
I have a Carrier Gas 58MCA with Air. The original Carrier
I have a Carrier Gas 58MCA with Air. The original Carrier thermostat went dead last night and I went out and purchased a programmable Honeywell thermostat. I connected everything as instructed. The R … read more
BillyHvac
BillyHvac
Journeyman Service Technician
State Licensed Mechanical Contractor
13,884 satisfied customers
I have a Carrier Weathermaker 8000 furnace, it failed to start,
I have a Carrier Weathermaker 8000 furnace, it failed to start, LED shows code 24. After opening up the furnace panel, saw the 3Amp fuse was blown, replaced with new fuse but immediately got blown aga… read more
Phil
Phil
Mechanical Engineer
Degree, Mech Engr Technology
7,634 satisfied customers
Billy I spoke to u on the 02 01 12 about my carrier furnace
Hello Billy I spoke to u on the 02 01 12 about my carrier furnace and u told me u though it was the gas valve. I contacted the expert he suppose to come tommorow. But the furnace has a new problem. Th… read more
BillyHvac
BillyHvac
Journeyman Service Technician
State Licensed Mechanical Contractor
13,884 satisfied customers
hello I have a carrier weather maker 8000 model #58wav091-14
hello I have a carrier weather maker 8000 model #58wav091-14 , the furnace works - lights etc but blower does not work on high speed , seems to blow very slow ???… read more
Phil
Phil
Mechanical Engineer
Degree, Mech Engr Technology
7,634 satisfied customers
hello my bryant furnace blowing fuses so i replaced the board.
hello my bryant furnace blowing fuses so i replaced the board. now as soon as we try to conect the thermostat it keeps blowing the 3amp fuse in the board...any ideas?… read more
Tim H.
Tim H.
Lead building engineer
Vocational, Technical or Trade Scho
3,962 satisfied customers
I have an RWB9 programmer and it keeps blowing the 3amp fuse!
I have an RWB9 programmer and it keeps blowing the 3amp fuse! If I take the programmer off and switch the 3amp switch on again (after changing fuse of course), it doesn't blow the fuse. So I presumed … read more
M Oglesby
M Oglesby
Vocational, Technical or Trade Scho
2,038 satisfied customers
my 3amp fuse keeps blowing every time i call for heating,my
my 3amp fuse keeps blowing every time i call for heating,my cooling and fan speeds works fine. i used a new piece of t-stat wire and also jump the r/w from the furnace and it still blows, changed the … read more
BillyHvac
BillyHvac
Journeyman Service Technician
State Licensed Mechanical Contractor
13,884 satisfied customers
my General humidifier that is duct attached and starts
my General humidifier that is duct attached and starts off the furnace fan power, keeps on blowing the 3AMP fuse on the furnace… read more
Tim H.
Tim H.
Lead building engineer
Vocational, Technical or Trade Scho
3,962 satisfied customers
I have a gas furnace Model #KG6RC 080C-16B. The fuse keeps
I have a gas furnace Model #KG6RC 080C-16B. The fuse keeps blowing. It will run for about five minutes, i have already replaced the transformer and board. Any hints.… read more
Phil
Phil
Mechanical Engineer
Degree, Mech Engr Technology
7,634 satisfied customers
The 3Amp fuse on our Carrier gas furnace keeps breaking. The
The 3Amp fuse on our Carrier gas furnace keeps breaking. The indicator code blinking after the fuse breaks indicates a possible short circuit on the secondary 24VAC wiring. We have replaced the fuse, … read more
BillyHvac
BillyHvac
Journeyman Service Technician
State Licensed Mechanical Contractor
13,884 satisfied customers
I have a Carrier 58PAV. Im getting an error code 24. Apparently
I have a Carrier 58PAV. I'm getting an error code 24. Apparently a thermostat lead problem. How do I troubleshoot and fix? No heat. No fan. Just the LED light flashing. Thanks, BP… read more
BillyHvac
BillyHvac
Journeyman Service Technician
State Licensed Mechanical Contractor
13,884 satisfied customers
Hi. I have a 2006 carrier infinity system with 4 zones. All
Hi. I have a 2006 carrier infinity system with 4 zones. All carrier equipment. The keypads were blank yesterday. I replaced the 3a fuse. everything was fine. This evening, when I got home from work, t… read more
BillyHvac
BillyHvac
Journeyman Service Technician
State Licensed Mechanical Contractor
13,884 satisfied customers
I have a park model trailer with a Nordyne furnace. A central
I have a park model trailer with a Nordyne furnace. A central air unit was added later. The furnace/ ac is now blowing the 3amp fuse located on the circuit board. If we don't turn the furnace/ ac on f… read more
Mark Henley
Mark Henley
HVAC Controls DDC
3,216 satisfied customers
hello we have a carrier furnace modele 58 PAV. Intenitently
hello we have a carrier furnace modele 58 PAV. Intenitently the fuse on the control board blows, and the system generates error code 24, We have check for loose wires and obvious sources of shorts and… read more
coolman1973
coolman1973
AC/Heat Tech
Vocational, Technical or Trade Scho
162 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Phil

Phil

Mechanical Engineer

7,634 satisfied customers

Retired HVAC/ Electrical & Boiler contractor. Industrial

Rick Mather

Rick Mather

HVAC Technician

3,133 satisfied customers

35 years experience, HVAC

Matthew

Matthew

HVAC Technician

2,014 satisfied customers

14 years experience in the HVAC field of service, installation, Manual J & D calculations

Brian HVAC Guy

Brian HVAC Guy

HVAC Technician

1,024 satisfied customers

I have been an HVAC/R mechanic/technician for 30+ years.

Kenton Guidry

Kenton Guidry

HVAC Technician

963 satisfied customers

12 years install/service experience.

Rick Ridley

Rick Ridley

UK Heating Engineer

871 satisfied customers

Retired But have had 30 years on the tools, Ex CORGI

Tom

Tom

HVAC Technician

770 satisfied customers

16+yrs HVAC/R service. Residential Commerical Industrial

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x