The color code to install new thermostat. Ruud furnace an

Customer Question

The color code to install new thermostat. Ruud furnace an a.c. 2007. Uhsa- hm2417ja. The wire colors are RED, YELLOW, BLACK-UNUSED IN PREVIOUS THERMOSTAT- DARK BROWN, PURPLE, PINK, LIGHT BROWN (TAN). PLEASE help me figure out the proper wiring scheme for my new thermostat.
JA: Just to clarify, do you think this is a larger HVAC problem, or something specific to the thermostat?
Customer: The wiring color code from the RUUD is not standard
JA: Do you plan on doing the work yourself?
Customer: Yes
JA: Anything else we should know to help you best?
Customer: Not that I can think of at the moment
Submitted: 2 months ago.
Category: HVAC
Expert:  airheatman replied 2 months ago.

Can you tell me where each wire went on old thermostat? And model of new thermostat?

Customer: replied 2 months ago.
No, I had a picture, but the wiring was so bad with the cracked and discolored insulation, that by the time I prepped them for the new thermostat, they looked entirely different. That is why I am looking for help. The new thermostat is a Honeywell 2300
Expert:  airheatman replied 2 months ago.

OK lets se what we can do. THe UHSA I an electric furnace. What is model on your ac outside.

Expert:  airheatman replied 2 months ago.

You will have to look to see what colors are ran between units but here is how they go based on colors in unit.

Air handler Red to R with a jumper to RC at thermostat

Air handler Brown (tape off) at thermostat but run to contactor in outdoor

Air Handler Green and black to G at thermostat

Air handler white/blue and white black tied together and to W at thermostat

Yellow from thermostat to contactor in outdoor unit.

Expert:  airheatman replied 2 months ago.

SeeE diagram below

Expert:  airheatman replied 2 months ago.

THis is for an air conditioner on,non heat pump. Get me model on outdoor and I will verify you have an air conditioner and not a heat pump.

Customer: replied 2 months ago.
Here is what the wire colors look. Most schematics and diagrams offer little if any
Expert:  airheatman replied 2 months ago.

1. What is model on outdoor unit?

2.SEnd me a pic of the other end of these wires at air handler

Customer: replied 2 months ago.
Pics of the old and new thermostat.
Customer: replied 2 months ago.
The model is HM2147JA
Expert:  airheatman replied 2 months ago.

I am suspecting your outdoor is a heat pump since you have o many wires.If so the 2300 is not a good replacement.Notice it has no EMER Heat selection.Give me model on outdoor unit so I can verify.The HM2417 is air handler

Customer: replied 2 months ago.
The new thermostat is a Honeywell
RTH221B. The old thermostat is a Rodgers White 1f73.
Customer: replied 2 months ago.
Expert:  airheatman replied 2 months ago.

Give me model on outdoor unit so I can verify

Customer: replied 2 months ago.
It has a heat pump
Customer: replied 2 months ago.
I can reconnect the White Rodgers. I just need a color conversion and I am good. I was out shopping earlier.
Expert:  airheatman replied 2 months ago.

OK the 2300 is not compatible .You need a 2 stage heat/1 stage cool thermostat.ee excerpt from manual

Expert:  airheatman replied 2 months ago.

If you want to reconnect the old we can do that, but I need a picture showing me where those wires connect at other end.

The problem is that their is no industry standard.For example one tech may use pink for common where another text ay use pink for ac and blue for common. Guessing can cause you to do a lot of damage to control board and transformer.

Customer: replied 2 months ago.
It's the Honeywell RTH 221B.
Customer: replied 2 months ago.
I have a multimeter to use
Customer: replied 2 months ago.
Here is a pic of White Rodgers 1f73 mounted with terminal screws
Customer: replied 2 months ago.
Where I love the roof is inaccessible to get pics. You are telling me things that I am already aware of.