I have a 09620 as well it has going to C, red to R, blue

Customer Question

I have a 09620 as well it has brown going to C, red to R, blue going to M2green going to G and white going to O and yellow to Y1. I am installing a Nest and it has no O and M2 so where does my blue and white go to? I have forced air Carrier system.
Thanks,
Submitted: 1 year ago.
Category: HVAC
Customer: replied 1 year ago.
I have a 09620 as well it has brown going to C, red to R, blue going to M2green going to G and white going to O and yellow to Y1. I am installing a Nest and it has no O and W2 so where does my blue and white go to? I have forced air Carrier system model FA4ANF036
Expert:  Daniel Plourde replied 1 year ago.
Hi i am dan. I can help you with this. Is it a heat pump you have?
Customer: replied 1 year ago.
I think so
Expert:  Daniel Plourde replied 1 year ago.
If it is a heat pump I would double check the m2 terminal. It is most likely a W2 and will go to W2 on the nest. The nest has an O/B terminal that is where you will connect the white wire
Expert:  Daniel Plourde replied 1 year ago.
Did that help you or do you have any more questions about it?