Customer: Hi ***** *****! Happy...
Customer: Hi ***** *****! Happy New year! Are you available for a question?
JA: Thanks. Can you give me any more details about your issue?
Customer: Yes okay my Trane xv80 furnace was blowing cold air last night (well tepid) and i went down and it was flashing 4 times..looked it up and indicated a tempature issue...yep the filter ws a disaster! whoops...black and filthy. I replaced it but cant seem to find a reset so every time I turn it back on no heat. I googled every direction to find a picture of it but I cant find one. What is your advice? I am a total new to all this...and im cold, lol
JA: OK got it. Last thing — JustAnswer charges a fee (generally around $18) to post your type of question to HVAC Experts (you only pay if satisfied). There are a couple customers ahead of you. Are you willing to wait a bit?
Customer: how long?
JA: OK. Now I'm going to take you to a page to place a secure deposit with JustAnswer. Don't worry, this chat is saved. After that, we will finish helping you.
Submitted: 1 year ago.Category: HVAC
Show More
Show Less
Ask Your Own HVAC Question
Answered in 8 minutes by:
1/1/2016
HVAC Technician: airheatman, HVAC Technician replied 1 year ago
airheatman
airheatman, HVAC Technician
Category: HVAC
Satisfied Customers: 8,502
Experience: Furnace, A/C and heat pump specialist.
Verified

Lets start by looking on the blower housing for a limit with a small button in between the wires that pushes in to reset.

Ask Your Own HVAC Question
Customer reply replied 1 year ago
okay thanks! this is Chinese to me. I looked around and didnt see any obvious button. there are several black boxes on it maybe under those?
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Should have 2 yellow wires going to it

Ask Your Own HVAC Question
Customer reply replied 1 year ago
ok be right back! ty
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Take your time.Should be on the housing of the blower

Ask Your Own HVAC Question
Customer reply replied 1 year ago
im going to look but maybe I may need to text you a pic
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Let me see if I can find a pic.

Ask Your Own HVAC Question
Customer reply replied 1 year ago
K I found two yellow wires they went down to what i think is the cover on a blower. they each plug into either side of a little black disc- smaller than a dime but there is no red button there...
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Can you attach picture

Ask Your Own HVAC Question
Customer reply replied 1 year ago
okay let me see how to do that...I cant shoot it and text right from my iphone right?
Customer reply replied 1 year ago
wait im going to take laptop down and shoot...just a momment
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Lets do this follow those yellow wires and see if there are any resettable limits that have a button to pus\hk,Should have a couple around burners also.

How long has it been since furnace quit?The non ressetables should cool down and reset themselves after several minutes.

If you have a paper clip icon on your page you can attach using that link.Or

You can upload the pictures using the tiny pic site .

Here is a link to the site.

http://tinypic.com/

Click on Browse , select the file from your folder.then click UPLOAD NOW.

They will give you a quote to enter in the box to verify you are a human.Enter the quote and click UPLOAD NOW

You will see your picture on right side of screen.

Then copy the link URL for email & IM

Paste that link here on the site.

Ask Your Own HVAC Question
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Excellent job. That is the limit I suspect. Now since you have removed door panel the board should reset and limit should definitely have had time to cool down. Hold door switch in or put panel back and see if furnace will work now or we still get error code.

Ask Your Own HVAC Question
Customer reply replied 1 year ago
okay I did that twice already this morning and still kicks on but blows tepid.
Customer reply replied 1 year ago
i had to shove my laptop under upside down lol glad pics came out ok! lol
Customer reply replied 1 year ago
same code 4 flashes but Ill try again?
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

OK lets check the other limits.Look above burners for ones with reset buttons.

http://i.imgur.com/CGkB9sa.jpg

Ask Your Own HVAC Question
Customer reply replied 1 year ago
okay where is that?
Customer reply replied 1 year ago
I literally looked everywhere accessible. ill take anther picture
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Take me a pic with top panel removed where burners are

Ask Your Own HVAC Question
Customer reply replied 1 year ago
okay THAT was the missing link! I didnt realize that top panel came off!
Okay I have a pic and I found the yellow wires and two of those but the little red buttons didnt feel like a good click or reset feeling- they just wiggled a little. Ill send a pic n a second
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

If none of them will reset it is possible one of the limits has opened and stuck open.

There should be 4 limits on the furnace.To determine which one is stuck open we can bypass each one until we get error code to go away and furnace to ignite.

One is on blower housing that you sent picture of. two are the flame rollouts with buttons and other is about the size of a credit card above burners in center of furnace vestibule.

Ask Your Own HVAC Question
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

To bypass them one at a time. unplug wires from limit and connect wires together using a small fuse, wire or straightened paper clip

http://i.imgur.com/Aqd9O0f.png

http://i.imgur.com/WqmGzzO.png

Ask Your Own HVAC Question
Customer reply replied 1 year ago
thud*....that was me fainting...lol
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

You have got this.I am here to guide you .Together I am confident we can get this figured out.

Ask Your Own HVAC Question
Customer reply replied 1 year ago
okay so step by step for this newb...Do the paperclip then try to fire up?
then repeat for each station?
Or do them all then fire it up at the end?
Customer reply replied 1 year ago
okay great...if you can sequence this for me that would be great. like step by step
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

One limit at a time.We are trying to find which limit is "open",

Lets start with that one on blower. Disconnect the 2 yellow wires, put the paper clip in wire connections to close circuit.Make sure paper clip can not touch metal and short out. The power on and see if error code is gone.If not we will move to next one.

Ask Your Own HVAC Question
HVAC Technician: airheatman, HVAC Technician replied 1 year ago
Ask Your Own HVAC Question
Customer reply replied 1 year ago
the ones/wires in the picture are not yellow but I look for yellow ones right?
Customer reply replied 1 year ago
okay Im going to come back to this in about two hours are you still going to be available?
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Absolutely.WE will go from here

Ask Your Own HVAC Question
Customer reply replied 1 year ago
okay we are back and ready to go try this
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

OK I am standing by.Let me know what you need

Ask Your Own HVAC Question
Customer reply replied 1 year ago
okay which is the blower? having trouble figuring out where to start
Customer reply replied 1 year ago
okay the first one didnt fix problem. that was the bottom one near the fan correct?
Customer reply replied 1 year ago
what next
Customer reply replied 1 year ago
okay doing now
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Standing by

Ask Your Own HVAC Question
Customer reply replied 1 year ago
okay still blinks four times whats next
Customer reply replied 1 year ago
flame rollout left and right...any order??
Customer reply replied 1 year ago
okay still blinking four times after the last two are checked. Now what?
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Follow that circuit and verify there are absolutely no other limits in the circuit.(Sometimes diagrams vary from what you actually have). Then unplug the 12 pin connector on board, make sure all wires are seated in connector so they make contact with board when plugged in.

Ask Your Own HVAC Question
Customer reply replied 1 year ago
okay. done
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Still same code?

Ask Your Own HVAC Question
Customer reply replied 1 year ago
it did a code three
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Whole different can of worms. Now saying you have a pressure switch open. Power cycle furnace with switch by turnin gon and off and see what we get

Ask Your Own HVAC Question
Customer reply replied 1 year ago
done... no change...
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

What code now?

Ask Your Own HVAC Question
Customer reply replied 1 year ago
still 3
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Does the small vent motor come on?

Ask Your Own HVAC Question
Customer reply replied 1 year ago
exhaust vent?
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Remove the small rubber hose from exhaust motor housing leave attached to pressure switch suck on hose and see if pressure switch closes and furnace lights

Ask Your Own HVAC Question
Customer reply replied 1 year ago
did that same thing. no change...we could feel valve moving when sucking and blowing but still 3 lights
HVAC Technician: airheatman, HVAC Technician replied 1 year ago

Sounds like you may have a board going out.Really hate condemning a board, but when board syas we have an open limit , we prove all limits are closed, The board says we have an pen pressure switch and we can hear switch closing,board seems to be giving false codes,

Ask Your Own HVAC Question
Ask Phil Your Own Question
Phil
Phil
Phil, Mechanical Engineer
Category: HVAC
Satisfied Customers: 6,022
6,022 Satisfied Customers
Experience: Retired HVAC/ Electrical & Boiler contractor. Industrial

Phil is online now

A new question is answered every 9 seconds

How JustAnswer works:

  • Ask an ExpertExperts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional AnswerVia email, text message, or notification as you wait on our site. Ask follow up questions if you need to.
  • 100% Satisfaction GuaranteeRate the answer you receive.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Phil

Phil

Mechanical Engineer

6,022 satisfied customers

Retired HVAC/ Electrical & Boiler contractor. Industrial

Rick Mather

Rick Mather

HVAC Technician

3,133 satisfied customers

35 years experience, HVAC

Matthew

Matthew

HVAC Technician

2,014 satisfied customers

14 years experience in the HVAC field of service, installation, Manual J & D calculations

Kenton Guidry

Kenton Guidry

HVAC Technician

963 satisfied customers

12 years install/service experience.

Brian HVAC Guy

Brian HVAC Guy

HVAC Technician

953 satisfied customers

I have been an HVAC/R mechanic/technician for 30+ years.

Rick Ridley

Rick Ridley

UK Heating Engineer

871 satisfied customers

Retired But have had 30 years on the tools, Ex CORGI

Tom

Tom

HVAC Technician

770 satisfied customers

16+yrs HVAC/R service. Residential Commerical Industrial

< Previous | Next >

Related HVAC Questions
Goodman two stage gas furnace, 3 years old, currently is
goodman two stage gas furnace, 3 years old, currently is code in system status code says LO , its firing up but not staying on? … read more
HVAC Guru
HVAC Guru
Service Technician
Associate Degree
682 satisfied customers
Which symbol on the Friedrich heating/cooling unit is for
Which symbol on the Friedrich heating/cooling unit is for heat? Thank you! … read more
airheatman
airheatman
HVAC Technician
8,502 satisfied customers
I have a trane XL90 and it's not working properly. The
Hi there. I have a trane XL90 and it's not working properly. The igniter glows bright but once the gas valve opens (can hear it and smell it eventually) the glow stops and nothing happens. I have the … read more
HVAC Guru
HVAC Guru
Service Technician
Associate Degree
682 satisfied customers
I have 30 year old gas furnace (no air conditioner). the
Hi, i have 30 year old bryant gas furnace (no air conditioner). the problem is that the fan doesn't stop. searched internet and learned that mostly the problem is with the fan limit switch. however, i… read more
Webb-Guy
Webb-Guy
tech.
72 satisfied customers
My thermostat is cycling on and off vert frequently, about
my thermostat is cycling on and off vert frequently, about 20 to 30 seconds each … read more
HVAC Guru
HVAC Guru
Service Technician
Associate Degree
682 satisfied customers
My lennox heater is not heating. The thermostat is set. I
The thermostat is set. I did not check the filter, but it is only 10 months old and the fan is running, when I just trun on the fan … read more
airheatman
airheatman
HVAC Technician
8,502 satisfied customers
Carrier furnace 58mcb080-20 gas valve will not open... i
carrier furnace 58mcb080-20 gas valve will not open... i confirmed 24 volts going to valve... replaced the valve and same problem... i jumped 24 volts from the transformer and it opens no problem... n… read more
Billy
Billy
Journeyman Service Technician
State Licensed Mechanical Contractor
9,330 satisfied customers
I tried to install new Honeywell WiFi thermostat
Hi. I tried to install new Honeywell WiFi thermostat th9320wf5003. And it doesn't show display. In … read more
Billy
Billy
Journeyman Service Technician
State Licensed Mechanical Contractor
9,330 satisfied customers
We have a Weil-Mclain boiler that keeps going int lock out
Hello we have a Weil-Mclain boiler that keeps going int lock out mode. It runs for about 20 seconds and then shut off with a solid red light. We now have an amber and red solid light. Can you help? … read more
Rick the plumber
Rick the plumber
Owner
9,857 satisfied customers
Lady hru? I'm troubleshooting an American Standard Freedom
Good evening lady hru? I'm troubleshooting an American Standard Freedom 80 furnace that's indicated to me the thermal protection device is open. What do I need to do to fix the issue? … read more
Billy
Billy
Journeyman Service Technician
State Licensed Mechanical Contractor
9,330 satisfied customers
My remote doesn't communicate with my unit. Its not the
My remote doesn't communicate with my unit. Its not the remote and I tried to re sync them several times. No luck. The unit will not turn on … read more
Eddie
Eddie
Home Improvement Contractor and Repairs
High School or GED
952 satisfied customers
I have a Honeywell propane furnace and the pilot is out.
I have a Honeywell propane furnace and the pilot is out. Iwhen the propane guy came today he said it was an automatic electrical light one but it's not on … read more
HVAC Guru
HVAC Guru
Service Technician
Associate Degree
682 satisfied customers
I have a question about an electric tankless or on demand
hello, I have a question about an electric tankless or on demand water heater … read more
Rick the plumber
Rick the plumber
Owner
9,857 satisfied customers
My furnace won't start. Furnace is in attic. I disconnected
Yes, I disconnected thermostat and read no voltage on any leads … read more
airheatman
airheatman
HVAC Technician
8,502 satisfied customers
Im trying to add a c wire to a EB15e. I just bought this
I just bought this place and im trying to install a smart tem … read more
Daniel Plourde
Daniel Plourde
plumbing, hvac technichian
Vocational, Technical or Trade School
343 satisfied customers
I have a 19.9 Rheem 120 volt water heater it does not have a
I have a 19.9 Rheem 120 volt water heater it does not have a drain valve . how do I drain it ? … read more
Rick the plumber
Rick the plumber
Owner
9,857 satisfied customers
Quiteside minisplit shows E1 code when I switch it to heat.
quiteside minisplit shows E1 code when I switch it to heat … read more
Daniel Plourde
Daniel Plourde
plumbing, hvac technichian
Vocational, Technical or Trade School
343 satisfied customers
Trying to install Honeywell lyric t5 wi fi thermostat to
Trying to install Honeywell lyric t5 wi fi thermostat to control heat pump with 7 wires … read more
Daniel Plourde
Daniel Plourde
plumbing, hvac technichian
Vocational, Technical or Trade School
343 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x