Phil
Phil, Mechanical Engineer
Category: HVAC
Satisfied Customers: 6022
Experience:  Retired HVAC/ Electrical & Boiler contractor. Industrial
23932409
Type Your HVAC Question Here...
Phil is online now
A new question is answered every 9 seconds

I have a munchkin contender that will not lite. No codes

Customer Question

I have a munchkin contender that will not lite . No codes appear .unit comes on for 12seconds then a clicks and stops. Thanks jerry
Submitted: 1 year ago.
Category: HVAC
Expert:  Phil replied 1 year ago.

Hello,

Find the flame sensor or 'ionization rod' on the wiring diagram, then follow the wire to the flame sensor mount on the fire box, remove it, and clean the long sensor rod off with a scotch brite pot scrubber pad, or *plumbers sand cloth.

If that fails, take a clear, well focused photo of the wiring diagram glued to the inside of the service panel, close up and from straight on, and attach it here using the paper clip icon at the right end of the tool bar, or the '+attach files' link to left of your send button.

I will mark it up with trouble shooting instructions.

We can go from there.