I have a 1986 f150 302 with fuel injection. I have a break…

Customer Question
I have a 1986...

I have a 1986 f150 302 with fuel injection. I have a break out box on the computer circuit. My paperwork says that on pin 16 the spout circuit you should have 60-70hz. I have 412hz. All grounds have less than .05 volts when checked at battery ground. I am not sure where the increase in hz. is coming from. Changed distributor not the problem. Pin 16 is a input on the computer. Any ideas.

Mechanic's Assistant: Does the battery look like it's leaking? And does it have a strong smell -- like sulfur?

No sir battery in real good shape. No sulfur smell.

Mechanic's Assistant: Are you fixing your F150 yourself? What have you tried so far?

The original problem when I got the truck. It would start with starter fluid and would run good. It will continue to crank the rest of the day. Let it sit all night and will not crank the next morning. Yes I am working on the truck myself. I have replaced throttle body sensor, injectors, built a injector harness, knock sensor and the atmospheric calibration sensor for ambient temp. and a new distributor with ignition module.

Mechanic's Assistant: Anything else you want the mechanic to know before I connect you?

That's about it. I am retired and this my project for staying out of wives way.

Submitted: 9 months ago.Category: Ford
Show More
Show Less
Ask Your Own Ford Question
Answered in 7 minutes by:
12/2/2017
Ford Mechanic: roy, import/domestic specialest replied 9 months ago
roy
roy, import/domestic specialest
Category: Ford
Satisfied Customers: 8,092
Experience: ASE master tech for 40 years
Verified

hello, my name is ***** ***** I will be glad to assist you. please allow me a couple of minutes to gather some basic info.

Roy

Ask Your Own Ford Question
Ford Mechanic: roy, import/domestic specialest replied 9 months ago

ok, when it wont start, did you check for spark???

did you verify fuel pressure??? low fuel pressure will cause a crank/no start but if it runs it will stay running

Roy

Ask Your Own Ford Question
Customer reply replied 9 months ago
Go for it.
Ford Mechanic: roy, import/domestic specialest replied 9 months ago

it should have 35-45 lbs fuel pressure

Ask Your Own Ford Question
Customer reply replied 9 months ago
40 psi with key on. New coil and distributor. The high hertz from the ignition module is what has me confused. I have spark and correct fuel pressure. When I get it to crank with starting fluid I have a black soot coming from tail pipe, Like it is flooded.
Ford Mechanic: roy, import/domestic specialest replied 9 months ago

ok, you have 2 out of 3 things needed to run

timing is next. do you have a timing light to verify timing while cranking???

also, have you checked compression???

Roy

Ask Your Own Ford Question
Customer reply replied 9 months ago
Have not checked compression . Set timing yesterday the timing light after changing distributor. 10 degrees BTDC
Ford Mechanic: roy, import/domestic specialest replied 9 months ago

ok, good. concerned about timing chain.

Ask Your Own Ford Question
Customer reply replied 9 months ago
If the timing chain has moved then why does it run so good after you crank it. No backfire or lose of power. I replaced the computer and the high pressure fuel pump I fell to mention. Like I say this is a retirement project to keep me out of trouble with wife. Been working on it about a month, now I am determined to fix it.
Roy how could the compression affect it cranking with EFI?
Ford Mechanic: roy, import/domestic specialest replied 9 months ago

ok, I was under the assumption it does not run. I saw where you said when you first got it, did not see that it runs now, sorry.

have you had the coil tested?? weak spark will do this as well.

what is the voltage on pin 16???

Roy

Ask Your Own Ford Question
Customer reply replied 9 months ago
I broke the coil wire off the coil. That was one of the first things I replaced. Pin 16 is the 5 volt ground going to ignition module. This is really a strange problem I have. Not a mechanic but a 40 year electrician and I understand DC volts. I understand that the ignition module fires the engine on starting and the computer takes over after receiving the ignition spark from the ignition module and I just replaced the distributor with a new ignition module.
Customer reply replied 9 months ago
This truck is original with same motor and transmission from factory. I bought it from a 73 year old neighbor. If you would like some time to ponder over this that is fine. You have my number and you can get back with me. I appreciate your input so far. This thing must be possessed and an exorcism might be next.
Ford Mechanic: roy, import/domestic specialest replied 9 months ago

the dark green yellow is the ground for the module. if you use your test light and hit the negative side of the coil, the light should flash. that is the command for the module to fire the coil. that signal is based on the distributor pick up coil in the distributor itself.

the spout is sending a signal to the ecm from the module.

Roy

Ask Your Own Ford Question
Was this answer helpful?

How JustAnswer works

step-image
Describe your issueThe assistant will guide you
step-image
Chat 1:1 with a ford mechanicLicensed Experts are available 24/7
step-image
100% satisfaction guaranteeGet all the answers you need
Ask roy Your Own Question
roy
roy
roy, import/domestic specialest
Category: Ford
Satisfied Customers: 8,092
8,092 Satisfied Customers
Experience: ASE master tech for 40 years

roy is online now

A new question is answered every 9 seconds

How JustAnswer works:

  • Ask an ExpertExperts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional AnswerVia email, text message, or notification as you wait on our site. Ask follow up questions if you need to.
  • 100% Satisfaction GuaranteeRate the answer you receive.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

AlvinC answered a question about my Ford truck that only someone with an in-depth knowledge of his subject would have known what was going on.

Rich DUSA

Because of your expertise, you armed me with enough ammunition to win the battle with the dealer. They are installing a fuel filter and fuel pump at no charge to me.

MollyUSA

I needed help with my car on Saturday morning....got a response in 5 minutes, and it was the perfect solution. Thanks again to your service.

Jason V.Kirkland, WA

I do know, after going though this with JustAnswer, that I can somewhat trust my mechanic but I will always contact you prior to going there.

BRNew Jersey

I would (and have) recommend your site to others I was quite satisfied with the quality of the information received, the professional with whom I interacted, and the quick response time. Thanks, and be sure that I'll be back whenever I need a question answered in a hurry.

Stephanie PElm City, NC

used your service this weekend with "Trecers" help. thank you ,thank you, thank you. replaced an A/C fan motor. Local Auto Zone had part. $15.00 "tracer" fee and $40.00 for parts, I saved several hundreds of dollers at a shop. i will recommend you and use you in the future.

David L.Richmond, TX

9 dollars, 2 hours of my time, and I drove away. Your diagnosis was right on the mark. Thank you so much.

PhilMarysville, CA

< Previous | Next >

Meet the Experts:

Ron

Ron

ASE Certified Technician

25,182 satisfied customers

23 years with Ford specializing in drivability and electrical and AC. Ford certs and ASE Certs

Chris (aka- Moose)

Chris (aka- Moose)

Technician

29,223 satisfied customers

16 years experience

John Mc

John Mc

Ford Technician

5,495 satisfied customers

19 years Ford Lincoln Mercury experience

Chuck

Chuck

ASE Certified Technician

1,685 satisfied customers

33 Years Experience,Ford Senior Master,ASE Master,L1 Advanced Engine Performance

Cam

Cam

Journeyman Automotive Technician

10 satisfied customers

GM Grand Master Technician 2007. 14 years Automotive experience.

Mike V.

Mike V.

Auto Service Technician

1,591 satisfied customers

25 years experience on all makes and models, Licensed NYS Inspector.

Richard

Richard

ASE Certified Technician

1,524 satisfied customers

12 years at a Ford Lincoln/Mercury and Jaguar dealer as a technician and shop foreman.

< Previous | Next >

Related Ford Questions
First off, how much will this cost me? Although I haven't
First off, how much will this cost me? Although I haven't spent tons of money on this thing, I've spent several hundreds and tons of time. … read more
Jaybird61
Jaybird61
Master Automotive Mechanic
2,333 satisfied customers
1997 ford f250 4x4 5.8 liter we currently have no spark with
1997 ford f250 4x4 5.8 liter we currently have no spark with the spout plug install if you take the spout plug out the engine starts but runs rough Burns ***** *****ke engine is out of timing. We repl… read more
Jaybird61
Jaybird61
Master Automotive Mechanic
2,333 satisfied customers
Curious while browsing through 1988 2.9 ford ranger problems
curious while browsing through 1988 2.9 ford ranger problems I noticed Amede ? seemed to understand wiring issues, maybe everyone there is. I am in need one someone very well versed?… read more
kwiggins29059
kwiggins29059
Associate Degree
219 satisfied customers
88 ford f150 302. Replaced coil, spark plug wires, dist. new
88 ford f150 302. Replaced coil, spark plug wires, dist. new pip sensor, ignition module, Pip sensor tested fine, has had 2 new module, 3 new coils. Not getting any spark. I had fire once when i chang… read more
Kenny Z
Kenny Z
Ford Senior Master Technician
High School or GED
16 satisfied customers
Truck fired up was able to drive about 10 feet, then went silent!
Truck fired up was able to drive about 10 feet, then went silent! Tried cranking and nothing. Can hear fuel pump running...sprayed starter fluid... replaced coil (which is showing no fire) still nothi… read more
Dan
Dan
Automotive Technician
Vocational, Technical or Trade Scho
25 satisfied customers
1988 Ford: 2WD 4.9L Cranks over wont start..fuel injector
1988 Ford PU 1/2Ton 2WD 4.9L Cranks over won't start. Checked for spark, and fuel injector pulse. No spark, or injector pulse. Computer will cycle fuel pump relay when I go into computer to check for … read more
Ron
Ron
ASE Certified Technician
Vocational, Technical or Trade Scho
25,182 satisfied customers
88 ford e-150: dist..new module,new coil new cap rotor..start position
why would 88 ford e-150 w/302 fire 1 spark at firrst turrnover and 1 sparrk when yyou let off the keyy but never in between? i put in new dist. complete w/ new module,new coil new cap rotor and it has… read more
Steve
Steve
Ford tech Specializing in electronics
Associate Degree
1 satisfied customers
1994 ford f 150: replaced the distributor cap, rotor, coil..my truck
I have a 1994 ford f 150 that will not run with the spout out. I have replaced the distributor cap, rotor, coil, ignition control module, and tested the pip with a led test light at the ICM. I need to… read more
Anthony
Anthony
Master Automobile Technician
Vocational, Technical or Trade Scho
8,789 satisfied customers
GT: TEN MINUTES..tfi MODULE,COIL, PLUGS AND WIRES,AND IGNITION switch
88 5.0 GT AFTER RUNNING TEN MINUTES CAR DIES AND HAVE NO SPARK,,HAS NEW DISTRIBTOR,TFI MODULE,COIL, PLUGS AND WIRES,AND IGNITION SWITCH… read more
Ron
Ron
ASE Certified Technician
Vocational, Technical or Trade Scho
25,182 satisfied customers
1993 ford: ECM and crank sensor both test ok..coil..spark plugs
1993 ford truck 302 cranks but will not fire, tested ECM and crank sensor both test ok. Have power to the coil but can't get spark plugs.… read more
Ron
Ron
ASE Certified Technician
Vocational, Technical or Trade Scho
25,182 satisfied customers
88 f-150: loses power..hill ( big or small) It restarts..few min
I have a 88 f-150 4x4 300 six. It some times loses power, most of the time going up hill ( big or small) It restarts after a few min. to and hour. it sometimes goes for 2 or 3 hundred miles between fa… read more
Dodge expert
Dodge expert
ASE MASTER TECH, REPAIR FACILITY OWNER
High School or GED
3,636 satisfied customers
My truck runs a few minutes and quits..die..starting fluid
My truck runs a few minutes and quits. It seems to die to the lack of fuel. I can keep it running with starting fluid. I replaced the ITF module but with no success. Please give me your ideas. Thank y… read more
Tim West
Tim West
Service Manager
Computer/ Automotive certifications
16 satisfied customers
93 ford E-250: 4.9L v..injector pulse..PiP signal out of distributor
93 ford E-250, 4.9L v-6 mpfi. Vehicle cranks, but has no spark or injector pulse. PiP signal out of distributor- 8.5volts while cranking. Lab scope to PiP shows flat line 8.5 volts while cranking. pow… read more
Tim West
Tim West
Service Manager
Computer/ Automotive certifications
16 satisfied customers
1988 ford ranger: v6..wont start every time..fuel pressure..ecm
i have 1988 ford ranger 2.9 v6 manuel tranny it has a starting problem cranks but wont start every time you shut it off in order to get it started you have to just bump ignition switch over several ti… read more
Ron
Ron
ASE Certified Technician
Vocational, Technical or Trade Scho
25,182 satisfied customers
I have a 1986 F-150 302 w/ at 2wd Ive replaced the ...
I have a 1986 F-150 302 w/ at 2wd I''ve replaced the front gas tank fuel pump,high pressure pump,fuse link on the fender wall and put a compleat used distrubeture and new vacume lines and the moter cr… read more
Ron
Ron
ASE Certified Technician
Vocational, Technical or Trade Scho
25,182 satisfied customers
93 ford probe: cyl..it disconnect the SPout connector..terminal
93 ford probe 4-cyl 121.5cu- just replaced distrib - my Haynes manual says, to time it disconnect the SPout connector - which it claims is between battery and diag terminal. I cant find it anywhere. I… read more
32dmadden
32dmadden
Owner Emergancy Auto Service
Associate Degree
1,016 satisfied customers
1986 f-150: Replaced ignition module and ignition coil.
I have a 1986 f-150 302. I have no spark. Replaced ignition module and ignition coil. I still do not have spark, nor do I have spark to distributor cap. Think is distributor? If so I have never replac… read more
ford dr
ford dr
senior master technician
Vocational, Technical or Trade Scho
184 satisfied customers
1992 ford f-150: crank..ran rough..rough when cold 280,000 miles
1992 ford f-150. crank no start died on expressway. The morning prior ran rough when cold 280,000 miles. fault codes from key on engine off test are 211 for pip circuit failure and 322 for egr any ide… read more
ttiger79
ttiger79
Auto Mechanic
High School or GED
880 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x