I have a 2006 Fusion 4 cylinder, have power to the relay, I

Customer Question
scanned and there is signs...
I have a 2006 Fusion 4 cylinder, have power to the relay, I scanned and there is signs from a/c on and off signs from controller but a/c is not turning on. Please help its hot. ☹️ When checking relay I grounded signal wire and a/c works, but after the car is turned off it will not work. Thank You for your help.
JA: Have you checked the fuse? Have you checked for bad bulbs?
Customer: All fuses are good.
JA: What is the model of your '06 Ford?
Customer: Fusion
JA: Are you hoping to fix this yourself? What have you tried so far?
Customer: The a/c was working, motor was replaced. Freon was added and did not work (will not turn on). Checked all fuses tested relay.
JA: Anything else you think the mechanic should know?
Customer: Check for codes no codes. When grounded signal wire at relay #2 pin a/c compressor turns on but after the car is turned off it will not turn on any more.
JA: OK. Got it. I'm sending you to a secure page on JustAnswer so you can place the $5 fully-refundable deposit now. While you're filling out that form, I'll tell the Ford Mechanic about your situation and then connect you two.
Submitted: 1 year ago.Category: Ford
Show More
Show Less
Ask Your Own Ford Question
Answered in 12 minutes by:
6/15/2016
Ford Mechanic: Jeremy, Certified Diesel Technician/Electrician replied 1 year ago
Jeremy
Jeremy, Certified Diesel Technician/Electrician
Category: Ford
Satisfied Customers: 3,393
Experience: ASE, NATEF Engines and Electrical certified, EPA 608/609
Verified

My name is ***** ***** I will assist you with your question today.

I'm an independent contractor and I don't get paid until a rating has been made.

We can go back and forth as needed to help resolve the issue you are having. Follow ups are free after ratings, so rate in confidence!

You have 2 switches on the A/C lines. One is a high pressure switch that is closer to the condenser and the other is a low pressure switch that is closer to the accumulator. Check to see that you have power going across those switches. If not on one of them, that switch is bad and needs to be replaced.

Check them first.

__________________________________________________________________________________________________________________________

You want a 5 star service and I want to provide a 5 star service. Please consider that I don't know your skill level as well as I can't see, touch, smell, hear the vehicle/machine in question. Please provide as much detail as possible and I will provide as much back.

Once an answer is provided, you should see a rating screen. Please rate my personal service to you. The ratings are my personal feedback,

they are not the site feedback.

Thank you for allowing me to assist you through Just Answer!

Jeremy

Ask Your Own Ford Question
Customer reply replied 1 year ago
Ok si do thanks.
Ford Mechanic: Jeremy, Certified Diesel Technician/Electrician replied 1 year ago

Let me know what you find. Thanks.

Ask Your Own Ford Question
Customer reply replied 1 year ago
Ok KOEO A/C on, only has one switch by the fire wall three pron connector, no power.
Customer reply replied 1 year ago
Switch is on the smaller a/c line.
Ford Mechanic: Jeremy, Certified Diesel Technician/Electrician replied 1 year ago

No power to it? Then there is a fault inside the cab then.

This vehicle has an electronic system that is tied into the modules, too.

Can you go to a Autozone and have the vehicle scanned for codes to see if the controller or one of the sensors comes up? It will save a lot of time and aggravation. Autozone does the scans for free.

Ask Your Own Ford Question
Customer reply replied 1 year ago
I have a scanner, the only code that is on is PO-0452 EVAP Pressure Low.
Customer reply replied 1 year ago
Are you still there.
Ford Mechanic: Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems replied 1 year ago
Chad Farhat
Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems
Category: Ford
Satisfied Customers: 4,130
Experience: Owner at Carolina Auto Service & Sales , 20 years experience in Foreign & Domestic Vehicles
Verified

Hi my name is ***** ***** i will be assisting you

Ask Your Own Ford Question
Ford Mechanic: Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems replied 1 year ago

give few minutes i want to look up the wiring diagram since no power to the switches .

be right back with you few minutes

Thank You

Chad

Ask Your Own Ford Question
Ford Mechanic: Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems replied 1 year ago

the P0452 description fault ( I dont see this code causing you a/c malfunction , if u read what it is used for )

I m going to look up the wiring diagram for the a/c system and get back to you , we need to do some testing , but look like the problem is in the interior ,

a/c control head , BCM module , wiring etc ..

I will let you know something by this evening and tell what is a good time where you will be with the car .

Thank You ***** ( aka -Customer)

ASE Certified Tech

Ask Your Own Ford Question
Customer reply replied 1 year ago
I have the car with me.
Ford Mechanic: Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems replied 1 year ago

ok good , so we have no power on low pressure switch and you are missing ground on pin#2 if u give grounds manually the a/c works

,and all fuses and relay are checked ? correct?

thanks

Ask Your Own Ford Question
Ford Mechanic: Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems replied 1 year ago

how replaced the engine ,did you do it yourself ?

Ask Your Own Ford Question
Customer reply replied 1 year ago
ground pin #2 at a/c relay and a/c works.
Motor was installed in a different shop.
Ford Mechanic: Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems replied 1 year ago

the a/c was working before and now we have another engine & a/c not working ,If this truck was in my shop, I want to go over the engine job and look for any loose ground connection

hand raise on a lift and ;look under , did you do that or can you do it, we have to eliminates that the engine job is not the issue , if u told me you drove it for a day or 2 it could be a coincidence, but since it never started after the job , then we have to check there , unless the control head went bad, or two wires touching in the wiring harness grounding the circuit the pcm pin that goes to the relay ground for the a/c that u are grounding , really a multiple of reasons to be honest

but the ground is what u missing and we need to find the missing ground

Ask Your Own Ford Question
Ford Mechanic: Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems replied 1 year ago

now i m assuming the inside blower motor is not working correct .

Ask Your Own Ford Question
Ford Mechanic: Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems replied 1 year ago

have the blower motor resistor been checked ?

Ask Your Own Ford Question
Customer reply replied 1 year ago
Inside blower Is working. I already check engine compartment, did not find any loose wires or pinched wires. Pin #2 at relay should recieve a ground signal from PCM when turned on. My scanner showed that a/c is turned on whe I turn a/c to the on position.
Ford Mechanic: Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems replied 1 year ago

exactly, you should receive ground , so if the blower working ,so blower resistor a/c control issue ,then you have a bad ground wire between the pin#2 and the ecm , or pcm itself

you can trace the wire and do a continuity test on that pin#2 wire

Ask Your Own Ford Question
Ford Mechanic: Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems replied 1 year ago

unplug the a/c control head and then look at scanner does a/c still shows on ?

Ask Your Own Ford Question
Ford Mechanic: Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems replied 1 year ago

follow that pin# ***** to pcm and put your test light with positive lead on positive side of battery ( so u checking for ground) and test for ground when u cycle the a/c switch your test light should go off and on each time u cycle the switch

Ask Your Own Ford Question
Customer reply replied 1 year ago
Ok will do that. Thanks
Ford Mechanic: Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems replied 1 year ago

you welcome ,

good luck

Hope I was helpfull to you ,Let me know if you need anything else on it

A Positive rating is Much Aprecciated

This Post Will Stay Open for you to Come Back And Ask Me Any Follow Up Questions You May have On This Issue Even after You Rate Me

Thank You

Chad Farhat ( aka -Customer)
ASE Certified Technician

Ask Your Own Ford Question
Ask Chad Farhat Your Own Question
Chad Farhat
Chad Farhat
Chad Farhat, ASE Certified Technician A6 - Electrical / Electronic systems A7 Heating / Air conditioning systems
Category: Ford
Satisfied Customers: 4,130
4,130 Satisfied Customers
Experience: Owner at Carolina Auto Service & Sales , 20 years experience in Foreign & Domestic Vehicles

Chad Farhat is online now

A new question is answered every 9 seconds

How JustAnswer works:

  • Ask an ExpertExperts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional AnswerVia email, text message, or notification as you wait on our site. Ask follow up questions if you need to.
  • 100% Satisfaction GuaranteeRate the answer you receive.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

AlvinC answered a question about my Ford truck that only someone with an in-depth knowledge of his subject would have known what was going on.

Rich DUSA

Because of your expertise, you armed me with enough ammunition to win the battle with the dealer. They are installing a fuel filter and fuel pump at no charge to me.

MollyUSA

I needed help with my car on Saturday morning....got a response in 5 minutes, and it was the perfect solution. Thanks again to your service.

Jason V.Kirkland, WA

I do know, after going though this with JustAnswer, that I can somewhat trust my mechanic but I will always contact you prior to going there.

BRNew Jersey

I would (and have) recommend your site to others I was quite satisfied with the quality of the information received, the professional with whom I interacted, and the quick response time. Thanks, and be sure that I'll be back whenever I need a question answered in a hurry.

Stephanie PElm City, NC

used your service this weekend with "Trecers" help. thank you ,thank you, thank you. replaced an A/C fan motor. Local Auto Zone had part. $15.00 "tracer" fee and $40.00 for parts, I saved several hundreds of dollers at a shop. i will recommend you and use you in the future.

David L.Richmond, TX

9 dollars, 2 hours of my time, and I drove away. Your diagnosis was right on the mark. Thank you so much.

PhilMarysville, CA

< Previous | Next >

Meet the Experts:

Ron

Ron

ASE Certified Technician

24,155 satisfied customers

23 years with Ford specializing in drivability and electrical and AC. Ford certs and ASE Certs

Chris (aka- Moose)

Chris (aka- Moose)

Technician

27,937 satisfied customers

16 years experience

John Mc

John Mc

Ford Technician

5,495 satisfied customers

19 years Ford Lincoln Mercury experience

Chuck

Chuck

ASE Certified Technician

1,685 satisfied customers

33 Years Experience,Ford Senior Master,ASE Master,L1 Advanced Engine Performance

Cam

Cam

Journeyman Automotive Technician

10 satisfied customers

GM Grand Master Technician 2007. 14 years Automotive experience.

Richard

Richard

ASE Certified Technician

1,524 satisfied customers

12 years at a Ford Lincoln/Mercury and Jaguar dealer as a technician and shop foreman.

Mike V.

Mike V.

Auto Service Technician

1,335 satisfied customers

25 years experience on all makes and models, Licensed NYS Inspector.

< Previous | Next >

Related Ford Questions
Just replaced blower motor on a 2002 F350 and getting no air
Just replaced blower motor on a 2002 F350 and getting no air movement out of the vents at all checked for any obstruction and did not see anything I haven't found any vacuum lines that are disconnecte… read more
Dan
Dan
Automotive Technician
Vocational, Technical or Trade Scho
25 satisfied customers
I have a 2002 f150, when i turn vehicle off the blower motor
i have a 2002 f150, when i turn vehicle off the blower motor stays running. i herd the problem could be in the gem, or the cjb, is there a way to test the cjb when i have it out of the vehicle.… read more
mustangmike
mustangmike
AUTOMOTIVE TECHNICIAN
Vocational, Technical or Trade Scho
492 satisfied customers
Blower motor won't work, checked fuses and replaced
Blower motor won't work, checked fuses and replaced resistor … read more
Randall
Randall
Auto Technician / Consultant
Vocational, Technical or Trade Scho
69 satisfied customers
My 2007 Navigator EATC blower motor runs constantly on high
Hi Richard. My 2007 Navigator EATC blower motor runs constantly on high speed whenever engine is running. Temperature control seems to work perfectly as heat and AC operate as they should. Using the o… read more
davehop
davehop
Diagnostic Technician
Ford Master Certified Technician
1,171 satisfied customers
2010 F150 blower motor does not run. I do not have power to
2010 F150 blower motor does not run. I do not have power to any pin on resistor plug. No blown fuses found. … read more
Mike V.
Mike V.
Auto Service Technician
High School or GED
1,335 satisfied customers
Blower motor doesnt work, I can wiggle wires over the fuse
blower motor doesnt work, I can wiggle wires over the fuse box in the passenger floor board and sometimes it will come on, it may work for days or sometimes just seconds … read more
AMEDEE
AMEDEE
AUTOMOTIVE TECHNICIAN
Vocational, Technical or Trade Scho
9,105 satisfied customers
08mustang gt blower motor stops and starts while driving. No
08mustang gt blower motor stops and starts while driving … read more
AMEDEE
AMEDEE
AUTOMOTIVE TECHNICIAN
Vocational, Technical or Trade Scho
9,105 satisfied customers
My 2010 f150 blower motor heat/ac is not working, fuses are
my 2010 f150 blower motor heat/ac is not working, fuses are fine checked wire connectors ok advise please? ed … read more
Dan
Dan
Automotive Technician
Vocational, Technical or Trade Scho
25 satisfied customers
Blower motor stopped working. relay & fuses good, 189k, 2000
yes, checked all related fuses and replaced blower motor relay … read more
AMEDEE
AMEDEE
AUTOMOTIVE TECHNICIAN
Vocational, Technical or Trade Scho
9,105 satisfied customers
Just replaced the blower motor and relay on my 2010 Ford
Just replaced the blower motor and relay on my 2010 Ford Crew Cab F150 at my local Ford Dealership, now the fan blows but the air is not cold like it was before the blower motor went out. The electric… read more
Chris (aka- Moose)
Chris (aka- Moose)
Technician
Vocational, Technical or Trade School
27,937 satisfied customers
Trouble with blower motor, 240000 km, so i guess around
240000 km, so i guess around 150000 miles manual tranny … read more
TIM MOHR
TIM MOHR
SHOP OWNER
Master's Degree
8,037 satisfied customers
Replaced blower motor, radiator fan assembly with module,
replaced blower motor, radiator fan assembly with module, now AC is not getting as cold as it used too. And it is not consistant with temp and electric issue just started today with it almost shutting… read more
6Bucs
6Bucs
Senior Master Tech
Associate Degree
3 satisfied customers
Blower motor is humming, vibrating. Will run barely but
Blower motor is humming, vibrating. Will run barely but changing fan speed does nothing. Did it a couple of times last year but I could shut it off and restart the truck and it was fine. … read more
Chris (aka- Moose)
Chris (aka- Moose)
Technician
Vocational, Technical or Trade School
27,937 satisfied customers
2004 Taurus. The blower motor is heard running strong, but
2004 Taurus. The blower motor is heard running strong, but no air is coming out of the vents.… read more
HDGENE
HDGENE
Master Technician/Lead Technician
Associate Degree
2,835 satisfied customers
How to access the blower motor resistor for 2015 f350, Not
How to access the blower motor resistor for 2015 f350 … read more
Ron
Ron
ASE Certified Technician
Vocational, Technical or Trade Scho
24,155 satisfied customers
Blower motor for a/c not working in the front. 2007 ford
blower motor for a/c not working in the front. 2007 ford expedition. was intermitten but now nothing … read more
AMEDEE
AMEDEE
AUTOMOTIVE TECHNICIAN
Vocational, Technical or Trade Scho
9,105 satisfied customers
2010 Ford Expedition intermittent front blower motor
2010 Ford Expedition intermittent front blower motor operation. no control with manual control, and not when in auto either. Verified motor is operational, and problem seems to be in the controls. Whe… read more
David Craig
David Craig
OWNER/MECHANIC
Associates
3,921 satisfied customers
Replaced the blower motor resistor and the fan still will
replaced the blower motor resistor and the fan still will not work - where is the blower mtor in my 2010 F 150 so I can replace that … read more
Pete
Pete
Independent Auto Technician
Vocational, Technical or Trade Scho
138 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.