Electrical

Electrical Questions? Ask an Electrician Online.

Connect one-on-one with {0} who will answer your question

Related Electrical Questions
Have a 120/208/240/277v transformer. Need to know how to
have a 120/208/240/277v transformer. Need to know how to wire it for 277v input to 120 volt output? … read more
Sam I
Sam I
Electrician
Bachelor's Degree
2,211 satisfied customers
I'm getting 268 volts on my circuit. Will my 277 lights
I'm getting 268 volts on my circuit. Will my 277 lights still work … read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
6,201 satisfied customers
Currently performing electrical service work at a motel
Currently performing electrical service work at a motel built in the early 80's. This motel uses 4 42 slot branch circuit panels that use single pole 277v single pole circuits for their room ptac AC's… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
6,201 satisfied customers
I have a 277/480 wye 200 amp service to my building I have
I have a 277/480 wye 200 amp service to my building I have 114 amps of 277 lighting load connected what size transformer would I need to use the remaining available amps as single phase 120 power and … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,751 satisfied customers
I'm trying to replace an outdoor wall sconce and there are 2
hi i'm trying to replace an outdoor wall sconce and there are 2 options at checkout: either 120 volt or 120-277 volt … read more
George Smith
George Smith
Superintendent
Vocational, Technical or Trade School
1,011 satisfied customers
We have a 277v lighting system with t1296 flourescent bulbs.
We have a 277v lighting system with t1296 flourescent bulbs. The ballast are the old magnetic type. Some of the ballast make a loud buzzing sound. … read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
6,201 satisfied customers
Is it dangerous for a 120v hot and a 277v hot wire to share
Hi, is it dangerous for a 120v hot and a 277v hot wire to share a neutral? … read more
Sam I
Sam I
Electrician
Bachelor's Degree
2,211 satisfied customers
I have a simlar question about a started G snswered on.
i have a simlar question about a started Mike G snswered on … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,751 satisfied customers
I need 120/240 volts secondary. I have 480 volts 3 wire
I need 120/240 volts secondary. I have 480 volts 3 wire available for primary. Can I get my 240v from tap connections on a 480 v120/208v delta y transformer? If not what kind of transformer do I need.… read more
ProGrade
ProGrade
Electrical Contractor
564 satisfied customers
I HAVE A 9T51B0190G03 GE BUCK BOOST TRANSFORMER 277V COMMING
I HAVE A 9T51B0190G03 GE BUCK BOOST TRANSFORMER 277V COMMING IN AND 120V SECONDARY, ITS NOT CLEAR WHERE THE 277V NEUTRAL GOES, WHAT IS THE SH WIRE FOR.DOES IT GO ON H1-H4 277 HOT AND SH FOR THE NEUTRA… read more
ProGrade
ProGrade
Electrical Contractor
564 satisfied customers
How to replace an Advanced 71a6091 core and coil ballast for
How to replace an Advanced 71a6091 core and coil ballast for a 120 v metal halide light. The kit did not come with a igniter - just ballast and capacitor… read more
AssuredElectrical
AssuredElectrical
Electrical Contractor
High School or GED
3,844 satisfied customers
The power company here in the Philippines will be supplying
The power company here in the Philippines will be supplying two insulated wires at 220V for our house service. Can I use one wire as a ground or neutral for bonding and grounding and a single pole bre… read more
AssuredElectrical
AssuredElectrical
Electrical Contractor
High School or GED
3,844 satisfied customers
Steve I have some fans that are currently wired for 110v but
Steve I have some fans that are currently wired for 110v but can be rewired to run for 230 volt. Problem is I would really like to run them at 277v because the power to the building is 277/480 - 120/2… read more
Steve G.
Steve G.
Automation Engineer
824 satisfied customers
have a 15306 timer, on a 277volt lighting circuit, it was originally
have a 15306 timer, on a 277volt lighting circuit, it was originally connected to just the 277 volt circuit,does it have to have separate 120 volts to run clock motor… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,751 satisfied customers
I live in a condominium building that has 277 volts in all
I live in a condominium building that has 277 volts in all common areas for lighting and air conditioning. I have a storage area that has 277 volts in it and would like to have 120 volts instead. My q… read more
Paul
Paul
Owner
Vocational, Technical or Trade Scho
799 satisfied customers
i have two flourescent lights i installed in a room. both have
i have two flourescent lights i installed in a room. both have two ballasts, i hooked my black power lead to the two black leads coming off my ballasts and ran a jumper to the other set of ballasts an… read more
Alex
Alex
Owner
Bachelor's Degree
1,783 satisfied customers
i have a problem with a safety switch i have power on top but
i have a problem with a safety switch i have power on top but when i turn on the lever up i get no power to my togel switch and the fuses are ok what can i do… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
How to determine which wires are which voltage on a multi-tap
How to determine which wires are which voltage on a multi-tap ballast? I have some Cooper MHXB-400-MT low bay light fixtures that were previously wired for 120V. I'm moving them to a different shop an… read more
Joseph
Joseph
743 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Mike

Mike

Master Electrician

1,426 satisfied customers

Licensed Master Electrician - OnQ Certified Data Voice Audio Video Installer

Jason

Jason

Service Technician

4,783 satisfied customers

Over 20 years of experience in all types of installations, troubleshooting, and repairs.

Mike G.

Mike G.

Master Electrician

9,751 satisfied customers

Proven Professional 49 years Experience

Kevin

Kevin

Licensed Electrical Contractor

6,201 satisfied customers

33 years Licensed Electrical Contractor in Illinois, Adjunct College Electrical Instructor, Former Electrical Inspector, Diploma: Digital Electronics, FCC Amateur & Commercial Radio Licenses

electrifier

electrifier

Master Electrician

1,458 satisfied customers

Electrical contractor and electrical inspector for over 24 years with phone and networking expertise

Rich

Rich

Master Electrician

1,117 satisfied customers

Over 35 years residential, commercial, industrial wiring, install, troubleshoot, service, maintain

mrromex

mrromex

Electrical Technician

281 satisfied customers

over 40 years of all phases related to residential wiring and remodeling

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question