Related Electrical Questions
I have the same ge pump model # as this person had (found
I have the same ge pump model # as this person had (found link by searching my motor/pump combo on google. I do not have the wiring diagram that was attached to cover plate(sun faded away). Im trying … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,336 satisfied customers
Have Dayton 4fn97 230 v 7.5 hp. have T1 &T5 together & T4
have Dayton 4fn97 230 v 7.5 hp. have T1 &T5 together & T4 &T8 together for cc rotation. where does P1 & P2 go… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,336 satisfied customers
I'm wiring a 230v compressor motor, and need to verify that
I'm wiring a 230v compressor motor, and need to verify that I have wires properly combined. I will provide motor information below. Thank youMake: Steveco Farm Duty Model: MS182C17FB2A Labeled Wires P… read more
George Smith
George Smith
Superintendent
Vocational, Technical or Trade School
625 satisfied customers
Wiring an 1hp electric motor to a plug but there a number of
wiring an 1hp electric motor to a plug but there a number of wires and they are all black … read more
George Smith
George Smith
Superintendent
Vocational, Technical or Trade School
625 satisfied customers
Will, I have a jet 1340a lathe, recent production, and am
Hi will, I have a jet ghb 1340a lathe, recent production, and am trying to wire a new motor, a Leeson 2hp farm duty single phase dual voltage. Jet does not provide wiring diagrams for the motor connec… read more
George Smith
George Smith
Superintendent
Vocational, Technical or Trade School
625 satisfied customers
I'm trying to wire a smith and jones 2 hp motor 67824. CCw
I'm trying to wire a smith and jones 2 hp motor 67824. CCw 230v. The wires I'm using are red black white bare copper… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,336 satisfied customers
I am trying to hook up a leeson motor to an industrial exhaust
i am trying to hook up a leeson motor to an industrial exhaust fan using two legs and a 30 amp fused safety switch with 3 wires and 208 feed… read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
I have a Doerr 2 hp motor and need to know how to wire it into
I have a Doerr 2 hp motor and need to know how to wire it into my car lift. The car lift says Load 1 to T1 and Load 2 to T4 after it passes through the switches. That still leaves T5 (capacitor start)… read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
I have a Leeson 1 hp single phase reversible motor with wiresP1,
I have a Leeson 1 hp single phase reversible motor with wiresP1, P2, T2 T3 T8, T4 T5. It is wired for 230v right now and I am trying to hook up a 2 pole 6 post reversing drum switch and need to know h… read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
I have a Leland Faraday 1.5 hp 230vac single phase electric
I have a Leland Faraday 1.5 hp 230vac single phase electric motor running clockwise and I need it counter clock. It is wired with P1 to line, P2 capped, T2,T3,T8 together & T5,T4 to the other line. Th… read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
I have a Dayton elec motor that I want to use for a shop fan.
I have a Dayton elec motor that I want to use for a shop fan. The motor I believe is a 220v but I want to convert it to 110v. It has 6 yellow wires coming out of it T1 T2 T3 T4 T5 And I cant read the … read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
we have a new 2 hp motor reversing now for our lift it is a
we have a new 2 hp motor reversing now for our lift it is a WEG 2 hp 230 v cap start with 7 wires plus a ground that we are tring to hook up to a Bremas reversing drum switch the wires from the motor … read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
Smith+Jones 1/2 HP General Purpose Motor Wiring Diagram
JACustomer: Looking at the wiring diagram for a Smith+Jones 1/2 HP General Purpose Motor, model 67839 (typed below, you can open online using this link http://manuals.harborfreight.com/manuals/67000-6… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,336 satisfied customers
I have a Leland 1.5 HP 115/230V Single phase 4 wire motor.
I have a Leland 1.5 HP 115/230V Single phase 4 wire motor. What is the configuration for 230V? the schematic is gone. Right now T1 and T4 are hooked up for 115V with T2 and T3 wired in series.… read more
Jason
Jason
Service Technician
Associate Degree
4,220 satisfied customers
I am trying to wire a Leeson A4C17DH4H to my boat lift controller.
I am trying to wire a Leeson A4C17DH4H to my boat lift controller. I have a white, red,orange, black and green wire from my controller. A meter reading of 120V on the white and red when in the lift up… read more
Craig
Craig
Electrical Director
Vocational, Technical
2,287 satisfied customers
I just bought a used leeson 1/4 single ph. electric motor it
I just bought a used leeson 1/4 single ph. electric motor it has five basic wires T1-T2-T3-T5-T8 also P1 -P2 and 1 wire with alot of small print on it not sure how to wire it for low voltage thank you… read more
Craig
Craig
Electrical Director
Vocational, Technical
2,287 satisfied customers
Im trying to reconnect wires to a motor which became disconnected.
I'm trying to reconnect wires to a motor which became disconnected. I have a wiring diagram from the manufacturer and things look like they are correct except for the 'switch.' Many of the wires that … read more
Rich
Rich
Master Electrician
Vocational, Technical or Trade Scho
1,117 satisfied customers
LEESON MOTOR, SINGLE PH, 110 VOLT CATALOG #100006.00 HAS SIX
LEESON MOTOR, SINGLE PH, 110 VOLT CATALOG #100006.00 HAS SIX WIRES. T3,T8,T2,T5,T1,T4. how do I wire it to run clock wise. Its a new motor right out of the box, yes there is a plate on the side but it… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Mike

Mike

Master Electrician

1,426 satisfied customers

Licensed Master Electrician - OnQ Certified Data Voice Audio Video Installer

Jason

Jason

Service Technician

4,220 satisfied customers

Over 20 years of experience in all types of installations, troubleshooting, and repairs.

Mike G.

Mike G.

Master Electrician

9,336 satisfied customers

Proven Professional 49 years Experience

Kevin

Kevin

Licensed Electrical Contractor

5,358 satisfied customers

32 years Licensed Electrical Contractor in Illinois, Adjunct College Electrical Instructor, Former Electrical Inspector, Diploma: Digital Electronics, FCC Amateur & Commercial Radio Licenses

AssuredElectrical

AssuredElectrical

Master Electrician

3,264 satisfied customers

Contractor-42+ Years in the ElectricalTrade

electrifier

electrifier

Master Electrician

1,458 satisfied customers

Electrical contractor and electrical inspector for over 24 years with phone and networking expertise

Rich

Rich

Master Electrician

1,117 satisfied customers

Over 35 years residential, commercial, industrial wiring, install, troubleshoot, service, maintain

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.