Need an electrician. Today. Ballast change from magnetic to
Yes Ballast change from magnetic to electronic Magnetic wiring was 1 blue 1 red 1 black 1 white New electronic ballast is 2 blue 1 red 1 blackb1 white. Fixture is connected in series and is f96t12 8ft 60 watt 2 bulbs. Fixture has 1 red 1 blue on one end and 1 black and 1 white on the other end. How do the wires connect. The new ballast is a pro12 2N rated for f96t12 8ft Bulbs are f96t12 cw/ew… read more
David Bowden
David Bowden
Owner
6,160 satisfied customers
Replacing a ballast on a 2- 8 foot bulb fixture. Old ballast
replacing a ballast on a 2- 8 foot bulb fixture . Old ballast has a black and white wire at one end, and a red and a blue at the other. New ballast has a black and white at one end and a red and two b… read more
Sam I
Sam I
Electrician
Bachelor's Degree
2,265 satisfied customers
I am replacing an old ballast for a T12 single tube
I am replacing an old ballast for a T12 single tube florescent (Keystone Transformers RSL40) now out of production. Found what is listed as replacement electronic ballast on Ballastshop.com - KTEB-140… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,751 satisfied customers
I have an old T12 fixture -wires:1 blue, 1 red 1 white1
i have an old T12 fixture -wires:1 blue, 1 red 1 white1 blue. … read more
David Bowden
David Bowden
Owner
6,160 satisfied customers
Replacing a ballast in 4 bulb fluorescent 40 watt, T12. It
Replacing a ballast in 4 bulb fluorescent 40 watt, T12. It has 2 ballasts. The new ballast looks the same but smaller except the 2 yellow wires are on the same side as the white and black on the old o… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,751 satisfied customers
I am changing he ballast in a fluorescent light fixture, The
I am changing he ballast in a fluorescent light fixture, The current ballast is a Lumi-Kon R140-120 and the intended replacement is a GE T12. Are they compatible and are there any wiring problems The … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,751 satisfied customers
Magnetic to electronic ballast wiring JA: Sometimes electrical
old ballast has 1 white and 1 black wire on one end then one red and one blue on the other end. my lights are the single pin florescent type. my new electronic ballast has 1 white, 1 black, 2 yellow, 2 red, and 2 blue wires … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,751 satisfied customers
I'm trying to replace a 8 wire ballast (2 red, 2, 2 yellow,
Hey Pearl . . . I'm trying to replace a 8 wire ballast (2 red, 2 green, 2 yellow, 1 black, 1 white) with a 5 wire ballast (1 red, 2 yellow, 1 black, 1 white) on a two light fixture . . . the result is… read more
Steven Parent
Steven Parent
Journeymen Electrician
Electrical Journeyman Certificate
69 satisfied customers
Replacing ballast -T12-2 single pin lamp fixtures.
Replacing ballast for F96-T12-2 single pin lamp fixtures. Original ballast power fed from tombstones on one end of fixture, single red and blue ballast connections connected to plunger-end lamp holder… read more
AssuredElectrical
AssuredElectrical
Electrical Contractor
High School or GED
3,844 satisfied customers
I have a ge ballast model ge260ismv-n-diyb . 2 lamp fixture
I have a ge ballast model ge260ismv-n-diyb . 2 lamp fixture with 2f96t12 bulbs. One bulb lights. When I remove the lit bulb the other bulb lights. But both will not light at the same time.. They are 7… read more
AssuredElectrical
AssuredElectrical
Electrical Contractor
High School or GED
3,844 satisfied customers
Hello how r u I was wondering if u can help me out I was
Hello how r u I was wondering if u can help me out I was trying to change out a fluorescent fixture. I know that the black is hot and wht is neutral its a old magnetic ballast and the one I was replac… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,751 satisfied customers
I'm replacing a Mark III Energy Saver ballast R-2E75-S-TP on
I'm replacing a Mark III Energy Saver ballast R-2E75-S-TP on a 2 lamp fixture that has 2 f96T12 lamps. THe old ballast has 1 ea. Bl. WH. RRed, Blue wires. The new one has BL. Wh. 2 yellow , 2 Red and … read more
AssuredElectrical
AssuredElectrical
Electrical Contractor
High School or GED
3,844 satisfied customers
Got Sylvania ballast for replacement on a 2 light 4 foot florescent
Got Sylvania ballast for replacement on a 2 light 4 foot florescent fixture .instead of 2 yellow 2 blue and 2 red. it has only 1 red and two blue along with the black and white power wires. diagram sh… read more
ProGrade
ProGrade
Electrical Contractor
564 satisfied customers
I am changing an old GE magnetic ballast in a T12, 8FT. 2 lamp
I am changing an old GE magnetic ballast in a T12, 8FT. 2 lamp fixture to an electronic ballast. The old ballast has the black and white wires on one side and a blue and a red wire on the other side. … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,751 satisfied customers
I am upgrading my burned out magnetic ballasts and fluorescent
I am upgrading my burned out magnetic ballasts and fluorescent tubes with electrical ballasts and new tubes. The new ballasts are GE multi-volt pro-line high performance t12 for line current 120v-277v… read more
Machinc
Machinc
Retired
1,188 satisfied customers
This GE 140RS120 wont light. Both sockets changed out with
This GE 140RS120 won't light. Both sockets changed out with two blue wires inserted into one end of a new T12 socket and two red inserted into the other new socket. The line wires connected obviously.… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,751 satisfied customers
I am changing out a Magnetic ballast, F96T12 8 2 lamp fixture.
I am changing out a Magnetic ballast, F96T12 8' 2 lamp fixture. What is the new wiring diagram? My ballast has a white, black, red on one end and 2 blues on other end. Tell me color wires to connect t… read more
Alex
Alex
Owner
Bachelor's Degree
1,783 satisfied customers
I am replacing a magnetic ballast (two tube T12) in a six foot
I am replacing a magnetic ballast (two tube T12) in a six foot fluorescent fixture with an electronic ballast. The wiring is different and I have three qualified opinions on how to connect the wires. … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,751 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Mike

Mike

Master Electrician

1,426 satisfied customers

Licensed Master Electrician - OnQ Certified Data Voice Audio Video Installer

Jason

Jason

Service Technician

5,442 satisfied customers

Over 20 years of experience in all types of installations, troubleshooting, and repairs.

Mike G.

Mike G.

Master Electrician

9,751 satisfied customers

Proven Professional 49 years Experience

Kevin

Kevin

Licensed Electrical Contractor

6,877 satisfied customers

34 years Licensed Electrical Contractor in Illinois, Adjunct College Electrical Instructor, Former Electrical Inspector, Diploma: Digital Electronics, FCC Amateur & Commercial Radio Licenses

electrifier

electrifier

Master Electrician

1,458 satisfied customers

Electrical contractor and electrical inspector for over 24 years with phone and networking expertise

Rich

Rich

Master Electrician

1,117 satisfied customers

Over 35 years residential, commercial, industrial wiring, install, troubleshoot, service, maintain

mrromex

mrromex

Electrical Technician

281 satisfied customers

over 40 years of all phases related to residential wiring and remodeling

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x