Electrical

Electrical Questions? Ask an Electrician Online.

Connect one-on-one with {0} who will answer your question

Related Electrical Questions
I want to run 6/3 wire from my main panel, down through the
I want to run 6/3 wire from my main panel, down through the wall, across the house through the crawl space and out to a spa panel. I would staple the wire to the bottom of the floor joists, and run it… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
5,004 satisfied customers
Want to add a RV 30AMP service circuit from electrical panel
Want to add a RV 30AMP service circuit from electrical panel to RV pad on side of house. The electrical wire will run from the panel inside the wall to attic crawl space, through a existing 3/4" metal… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
5,004 satisfied customers
Electrical question. Is it code compliant to protect 12/2
Electrical question. Is it code compliant to protect 12/2 Romex wire with 1/2" flexible aluminum conduit? I've attached a screenshot of the product I want to use.… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
8,290 satisfied customers
I need to get 220v electric to a spa disconnect panel on a
I need to get 220v electric to a spa disconnect panel on a raised deck. I'd like to run #6-3 NM-B to a junction box near the basement wall penetration (to save me 60' of conduit) and transition to UF … read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
5,004 satisfied customers
Can I use Black 6-3 Romex NM- W/G Wire to provide power from
Can I use Black 6-3 Romex NM-B W/G Wire to provide power from an interior subpanel to a SPA GFCI disconnect? It will be run under the house attached to the joists and the GFCI will be mounted on the o… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
5,004 satisfied customers
I had an addition added to my house in 04 and they used 12 /
Hello I had an addition added to my house in 04 and they used 12 / 2 NM-B electrical wire outdoors under my kitchen crawlspace without conduit/protection to power the addition. Is this allowed accordi… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
5,004 satisfied customers
I just discovered charred wiring behind my kitchen light
Hi Jason. I just discovered charred wiring behind my kitchen light switch(after noticing a smell and the lights flickering) I'm sure I'll have to cut the wiring back but how do I install the new switc… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
5,004 satisfied customers
22 September 2015 07:00 never mind I see where I can give
22 September 2015 07:00 never mind I see where I can give you a bonus from the first question...thats easier for me...OKay here is my question. I want to install a mini split in my back room because i… read more
Jason
Jason
Service Technician
Associate Degree
3,958 satisfied customers
I am trying to replace an L10-30 (3 pole, 3 wire) receptacle
I am trying to replace an L10-30 (3 pole, 3 wire) receptacle with an L14-30 (4 pole, 4 wire grounding) receptacle. The receptacle is not very far from the panel (which is outside). Also, the 4 wire co… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
5,004 satisfied customers
Hot tub wiring: I have a hot tub which I wired personally.
Hot tub wiring: I have a hot tub which I wired personally. The hot tub requires 60 amp 240v service. I purchased 6 gauge copper 4 strand wire in an insulator (not cheap stuff!) and ran it about 75 fee… read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
I need some help with hooking up a hot tub. I plan on running
I need some help with hooking up a hot tub. I plan on running 6/3 romex inside the house (uninsulated ground). I cannot run it directly into the spa panel because the wire has to exit the house and th… read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
kevin you helped me with some wiring questions about a week
kevin you helped me with some wiring questions about a week ago. I am going to be running some wires up from the basement, across an office area, and into the laundry room. About a 25 foot run from th… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
5,004 satisfied customers
What Romex type should be used in a kitchen. They will run
What Romex type should be used in a kitchen. They will run from the service panel through conduit under an elevated home, crawl space. Once the wire goes under the house no conduit will be used. one b… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
8,290 satisfied customers
Ive got to wire an outdoor spa. What guage Romex should I
I've got to wire an outdoor spa. What guage Romex should I use to go from the dedicated 50 amp breaker in the service panel threw conduit 85' to the local disconnect box with another 50 amp breaker an… read more
Rich
Rich
Master Electrician
Vocational, Technical or Trade Scho
1,117 satisfied customers
The previous owner moved the dryer outlet from inside the house
The previous owner moved the dryer outlet from inside the house to inside the garage. Original wiring is AL. The previous owner added a junction box in the attic at the end of the conduit for the AL w… read more
Mike
Mike
Master Electrician
Working on MBA
1,426 satisfied customers
My ceiling light says that the hosue wiring should be rated
My ceiling light says that the hosue wiring should be rated for 75 degrees C. It also says that most house built before 1985 are rated for 60 degrees. My house was build in 1980. How can tell the wiri… read more
electrifier
electrifier
Master Electrician
Bachelor's Degree
1,458 satisfied customers
I am installing a security gate about 50 from my electrical
I am installing a security gate about 50' from my electrical service box which has 220VAC service and a 200amp breaker in a outside box between the main service line and the service to the house. Whil… read more
Paul
Paul
Owner
Vocational, Technical or Trade Scho
799 satisfied customers
I plan to interconnect two buildings with underground conduit.
I plan to interconnect two buildings with underground conduit. I plan to use 2 SCH 80." I plan to run 6/3 w-ground (I wasn't going to use the ground because the new building has its own rods). I have … read more
Paul
Paul
Owner
Vocational, Technical or Trade Scho
799 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Mike

Mike

Master Electrician

1,426 satisfied customers

Licensed Master Electrician - OnQ Certified Data Voice Audio Video Installer

Jason

Jason

Service Technician

3,958 satisfied customers

Over 20 years of experience in all types of installations, troubleshooting, and repairs.

Mike G.

Mike G.

Master Electrician

8,290 satisfied customers

Proven Professional 49 years Experience

Kevin

Kevin

Licensed Electrical Contractor

5,004 satisfied customers

32 years Licensed Electrical Contractor in Illinois, Adjunct College Electrical Instructor, Former Electrical Inspector, Diploma: Digital Electronics, FCC General Class License

AssuredElectrical

AssuredElectrical

Master Electrician

3,264 satisfied customers

Contractor-42+ Years in the ElectricalTrade

electrifier

electrifier

Master Electrician

1,458 satisfied customers

Electrical contractor and electrical inspector for over 24 years with phone and networking expertise

Rich

Rich

Master Electrician

1,117 satisfied customers

Over 35 years residential, commercial, industrial wiring, install, troubleshoot, service, maintain

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x