I am replacing a ceiling rose. The old fitting has two live
I am replacing a ceiling rose. The old fitting has two live and two neutral wires, all coming from the ceiling. The new rose has sockets for only one of each. What do I do? Doubling up doesn't feel ri… read more
Steve G.
Steve G.
Chief Engineer
801 satisfied customers
I am installing a ceiling light where a light / extractor fan
I am installing a ceiling light where a light / extractor fan switch used to be. The light and the fan used to have their own adjacent switches. The cable from the mains is just a single three core on… read more
Expert
Expert
General Building Contractor
22 satisfied customers
Hi, Im Jules. I am trying to attach a new light to existing circuit uk house built 1960. I
Hi, Im Jules. I am trying to attach a new light to existing circuit uk house built 1960. I have added a junction box to which I am connecting the supply cable from the new light. However, the circuit … read more
Machinc
Machinc
Retired
1,059 satisfied customers
I have a two gang switch in my hallway with 3 wires coming
I have a two gang switch in my hallway with 3 wires coming in. The one brings in power. The two I've identified have no power and go to the lights. To wire this up I'be placed the power cable's live i… read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
Hello, I have a 3 core cable (br, bl & gr/y) power feed to
Hello, I have a 3 core cable (br, bl & gr/y) power feed to my garage for lighting. the cable enters from one end of the garage and the switch needs to be at the other end with 3 light fittings between… read more
Steve G.
Steve G.
Chief Engineer
801 satisfied customers
Ive bought a ceiling fan/light. It takes just three wires:
I've bought a ceiling fan/light. It takes just three wires: live, neutral & earth. The standard light that it is replacing has 3 cables going to it, one in, one out & a live one to the switch. The fan… read more
kruzrken
kruzrken
Partner
Bachelor's Degree
217 satisfied customers
I just replaced an outside light connected to two three way
I just replaced an outside light connected to two three way switches. It surprised me to find that the neutral/white cable was connected to the ground cable at the lighting fixture junction box. When … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
8,290 satisfied customers
I have two x 2-lamp lighting circuits on my veranda, controlled
I have two x 2-lamp lighting circuits on my veranda, controlled separately from a 2-gang switch drawing power from a junction box in one of the main house lighting circuits. I just bought a new 2-gang… read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
fitted new fuse box with rcds ring main keeps triping as does
fitted new fuse box with rcd's ring main keeps triping as does cooker occasionally 0n a 32 amp rcd getting circuit from one earth to neutral & live supply from seperate junction box tried disconnectin… read more
The Famous Forry
The Famous Forry
High School or GED
615 satisfied customers
Im trying to fit some outside lights that run on normal supply.
Im trying to fit some outside lights that run on normal supply. I have fit a fused spur and run a cable outside which i need to wire into a double switch so i can turn two sides on seperately. I canno… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
House is 5 years old and wired for an switched indoor outside
House is 5 years old and wired for an switched indoor outside light. Light failed so replaced tungsten bulb fitting with a sensor halogen security light but did not work. Halogen light fitting doubled… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
Hi i am adding some kickboard lights [low voltage] in the
Hi i am adding some kickboard lights [low voltage] in the kitchen, the switch on the wall was a double switch, so i have bought a triple switch, my question is where do i put the red and black wires ,… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
I HAD ANE EXTRACTOR FAN IN MY BATHROOM WITH A PULL SWITCH ATTACHED
I HAD ANE EXTRACTOR FAN IN MY BATHROOM WITH A PULL SWITCH ATTACHED TO THE FAN I AM REPLACING IT WITH A MANROSE FAN WITH A RUN ON AND WIRED TO COME ON WITH THE BATHROOM LIGHT PULLSWITCH I HAVE REMOVED … read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
Hello. I want to replace an existing light. I have 2 cables
Hello. I want to replace an existing light. I have 2 cables coming through the ceiling one of which has an earth, live (brown) and neutral (blue) wire. The other has an earth, live (red) and neutral (… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
I have a live mains wire sticking out of a wall in my bathroom.
I have a live mains wire sticking out of a wall in my bathroom. I believe it was once attached to a light/shaver outlet thing. It is currently live and terminates in a cable joining box. What is the b… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
i was recently replacing a old light fitted with a 2 way light
i was recently replacing a old light fitted with a 2 way light switch (top and bottom of the stairs), whilst removing the rose it was damaged and the wiring got jumbled up. After a lot of time i can g… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
I am trying to fit a new light rose and light pendant & in
I am trying to fit a new light rose and light pendant & in trying to wire it up to the switch cable & two loop cables i keep blowing a fuse. The installation is complicated because the room was extend… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
I am installing a new spa using a 4 wire cable of 6 gauge each
I am installing a new spa using a 4 wire cable of 6 gauge each (6-4), there is a red, black, white and bare ground. I have installed a 50 amp breaker in my main board and want to run it through the wa… read more
Joseph
Joseph
743 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Mike

Mike

Master Electrician

1,426 satisfied customers

Licensed Master Electrician - OnQ Certified Data Voice Audio Video Installer

Jason

Jason

Service Technician

3,958 satisfied customers

Over 20 years of experience in all types of installations, troubleshooting, and repairs.

Mike G.

Mike G.

Master Electrician

8,290 satisfied customers

Proven Professional 49 years Experience

Kevin

Kevin

Licensed Electrical Contractor

4,414 satisfied customers

31 years Licensed Electrical Contractor in Illinois, Adjunct College Electrical Instructor, Former Electrical Inspector, Diploma: Digital Electronics, FCC Technician License

AssuredElectrical

AssuredElectrical

Master Electrician

3,264 satisfied customers

Contractor-42+ Years in the ElectricalTrade

electrifier

electrifier

Master Electrician

1,458 satisfied customers

Electrical contractor and electrical inspector for over 24 years with phone and networking expertise

Rich

Rich

Master Electrician

1,117 satisfied customers

Over 35 years residential, commercial, industrial wiring, install, troubleshoot, service, maintain

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x