I'm working on a small transformer primary 240 secondary
I'm working on a small transformer primary 240 secondary 120. it is an Emerson E050 with jumpers on H3/H2 and F1/F2. they have blown about 6 of these and now I am looking at it … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
8,290 satisfied customers
I was told this transformer will take 208v and make 460v.
I was told this transformer will take 208v and make 460v. Please see the schematic and pics and let me know if this is true? Because the secondary is labeled 250V.… read more
Sam I
Sam I
Electrician
B.S.
941 satisfied customers
Ok, I have an eaton cutler hammer single phase dry type transformer
Ok, I have an eaton cutler hammer single phase dry type transformer and I'm trying wire it back together on both sides, from my tanning bed which has 3 wires (white, black, green) to the transformer a… read more
Steven Parent
Steven Parent
Journeymen Electrician
Electrical Journeyman Certificate
69 satisfied customers
Please verify via this cutsheet, figure J on the last page
please verify via this cutsheet, figure J on the last page single phasehttps://www.platt.com/CutSheets/Actuant/AcmeBuck-Boost-Transformers.pdfwhat is my input? what is my output?seems like H4 and X1 a… read more
ProGrade
ProGrade
Electrical Contractor
564 satisfied customers
I need to convert 120/208v 3 phase to 460v 3 phase. using an
I need to convert 120/208v 3 phase to 460v 3 phase. using an existing buck boost transformer. Without the paper showing how to wire I am clueless.… read more
Steve
Steve
Chief Engineer
9 satisfied customers
How to wire a 480v 3phase transformer to 240/120v panel with
How to wire a 480v 3phase transformer to 240/120v panel with neutral. It has H1,H2,H3 lugs on the high side and x1,x2,x3,x4 on low side. x4 is a mid tap. it is a MIDWEST 30KVA 9T83W3842… read more
Dr. Fix-It
Dr. Fix-It
Technical Lead
1,671 satisfied customers
I have installed a 7500 watt 240 volt electric heater in my
I have installed a 7500 watt 240 volt electric heater in my garage but I am not getting much heat from it. Any ideas?… read more
Jason
Jason
Service Technician
Associate Degree
3,958 satisfied customers
I have a square D 250SV43B buck & boost transformer. It has
I have a square D 250SV43B buck & boost transformer. It has 4 RED WIRES: X1 X2 X3 X4 and 4 BLACK WIRES: H1 H2 H3 H4 How do I connect the wires on a 120 volt circuit to yield 12volts (for low voltage l… read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
Can anyone help me figure out how to rewire an Onan 7.5K Commercial
Can anyone help me figure out how to rewire an Onan 7.5K Commercial generator with a 12 wire harness running 240 3 phase to 120/240 single phase. I followed the schematics and connected T1 to hot, T2,… read more
Phil
Phil
Consultant to Engrs, Govt & Contractors
Degree, Mech Engr Technology
3,671 satisfied customers
I am hooking up our tanning bed using a buck/boost transformer.
I am hooking up our tanning bed using a buck/boost transformer. Our high volts is 240 and we need to reduce to 220-230volts. We've been trying to follow some schematics from diagrams but the DC is com… read more
Randy119
Randy119
President
High School or GED
7 satisfied customers
We have a new inverter supplied from a 60 amp 2-pole breaker
We have a new inverter supplied from a 60 amp 2-pole breaker delivering 120/208 volt single phase power. But, the inverter manufacture is asking for the voltage supplying the inverter to be 120/240 vo… read more
Jason
Jason
Service Technician
Associate Degree
3,958 satisfied customers
Hello Everyone, This question popped in my mind, I was
Hello Everyone, This question popped in my mind, I was thinking if I had a three phase system, and I don't have much trust on the wiring colours, How can I determine which phase is which? I know each … read more
Jason
Jason
Service Technician
Associate Degree
3,958 satisfied customers
I have ordered an Acme T-1-13075 buck boost transformer to
I have ordered an Acme T-1-13075 buck boost transformer to step up the voltage for my commercial range from 208 to 240V to make it more efficient at heating up the oven and self cleaning-- I have a lo… read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
Good evening My house is around 22 years old. I bought it
Good evening My house is around 22 years old. I bought it 6 years ago everything was working fine (electricity) I have made a few room renovation and ran 1 line by room and sometime 2 lines when neede… read more
Rich
Rich
Master Electrician
Vocational, Technical or Trade Scho
1,117 satisfied customers
Hello, I am the owner of an offset printing company. I have
Hello, I am the owner of an offset printing company. I have assisted electricians before, and installed on my own, more than a few three phase machines. I understand the voltages used with these insta… read more
Craig
Craig
Electrical Director
Electrical Automation Technician
2,133 satisfied customers
Im looking for a diagram and parts list to get a balanced
I'm looking for a diagram and parts list to get a balanced load out of my honda 6500is genny for running electronic 4KW ballasts in tv/film lighting. I saw someone else asked about it a few months bac… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
i have a square d 7s1f 7.5 kva step down transformer . i need
i have a square d 7s1f 7.5 kva step down transformer . i need to hook it up 240 primary and out secondary at 120 what i cannot figure out. is how do i use a 30amp 3 wire twistlock nema plug to feed pr… read more
Electrical Doctor
Electrical Doctor
Master Electrician
Associate Degree
8 satisfied customers
I am going through this same thing as well. I can post a picture
I am going through this same thing as well. I can post a picture of the wiring diagram but I dont know how the quality will be but I can try. There are 8 terminals as were described above. Timer, time… read more
Electrical Doctor
Electrical Doctor
Master Electrician
Associate Degree
8 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Mike

Mike

Master Electrician

1,426 satisfied customers

Licensed Master Electrician - OnQ Certified Data Voice Audio Video Installer

Jason

Jason

Service Technician

3,958 satisfied customers

Over 20 years of experience in all types of installations, troubleshooting, and repairs.

Mike G.

Mike G.

Master Electrician

8,290 satisfied customers

Proven Professional 49 years Experience

Kevin

Kevin

Licensed Electrical Contractor

4,414 satisfied customers

31 years Licensed Electrical Contractor in Illinois, Adjunct College Electrical Instructor, Former Electrical Inspector, Diploma: Digital Electronics, FCC Technician License

AssuredElectrical

AssuredElectrical

Master Electrician

3,264 satisfied customers

Contractor-42+ Years in the ElectricalTrade

electrifier

electrifier

Master Electrician

1,458 satisfied customers

Electrical contractor and electrical inspector for over 24 years with phone and networking expertise

Rich

Rich

Master Electrician

1,117 satisfied customers

Over 35 years residential, commercial, industrial wiring, install, troubleshoot, service, maintain

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x