Electrical

Electrical Questions? Ask an Electrician Online.

Ask an Expert,
Get an Answer ASAP!

Related Electrical Questions
Background: 6,600 Sq ft house, 35 years old, well built.
Background: 6,600 Sq ft house, 35 years old, well built. Basement on complete opposite end of house. In May, we replaced two of three HVAC units from gas to electric and replaced gas hot water heater … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
8,290 satisfied customers
Is an external thermostat required or can the unit control
hello is an external thermostat required or can the unit control temps on its own internally… read more
Alex
Alex
Owner
Bachelor's Degree
1,783 satisfied customers
My house is a lil under 4000 Sq ft, been updating the
My house is a lil under 4000 Sq ft, been updating the electrical for almost 2 years now. Now that I'm almost finished, would it be normal for my electric bill to be higher until I disconnect the old p… read more
ProGrade
ProGrade
Electrical Contractor
564 satisfied customers
Kenmoore gas hot water heater won't stay lit.. Showing 5
Kenmoore gas hot water heater won't stay lit.. Showing 5 blinking lights saying temp sensor defective. Model number is###-##-####.… read more
Rick the plumber
Rick the plumber
Owner
9,857 satisfied customers
Good day, I purchased a Dimplex 5000W 240 V garage heater
Good day, I purchased a Dimplex 5000W 240 V garage heater and I am trying to bypass the internal thermostat. I have already run 10 Guage 30 Amp 2 wire cable to a 30 amp double breaker. I also purchase… read more
AssuredElectrical
AssuredElectrical
Master Electrician
High School or GED
3,264 satisfied customers
I live outside of the US so inspections and codes do not apply.
I live outside of the US so inspections and codes do not apply. However I do still want everything to be safe. I want to instal two 220v window ac units in a greenhouse (my house is wired 110). Each i… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
8,290 satisfied customers
I want to do a 60 foot run from a main panel to a sub panel
I want to do a 60 foot run from a main panel to a sub panel for pool equipment. I just want to trench and run the conduit - I will let a licensed electrician connect to the main panel What guage wire … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
8,290 satisfied customers
I need a power converter to convert 110V AC to 12V DC - I'm
I need a power converter to convert 110V AC to 12V DC - I'm not sure exactly how many amps the DC motor I am using draws? What I need to know is - if I get a converter that puts out 12V 12 Amps DC, if… read more
Phil
Phil
Consultant to Engrs, Govt & Contractors
Degree, Mech Engr Technology
3,671 satisfied customers
HELP. This is driving me nuts!!! I live in an apt. in a
HELP. This is driving me nuts!!! I live on the third (top) floor in an apt. in a rehabbed vintage building. Two months ago, I left the central air on and there was a power outage while I was away. Whe… read more
Phil
Phil
Consultant to Engrs, Govt & Contractors
Degree, Mech Engr Technology
3,671 satisfied customers
Hi, I am hooking up the air conditioner on a new home. The
Hi, I am hooking up the air conditioner on a new home. The builder ran a 12 guage wire to the outside of the home. Does that seem like a big enough gauge for a 3 ton AC? What size circuit breaker shou… read more
Jason
Jason
Service Technician
Associate Degree
3,958 satisfied customers
I have a burnt outlet that my built in airconditioner runs
I have a burnt outlet that my built in airconditioner runs on. The cable is home run to the panel and is 12/3, 220/20amp and is aprox 10 years old the plug was Leviton 20amp/250volt. The cable itself;… read more
Mike
Mike
Master Electrician
Working on MBA
1,426 satisfied customers
I am trying to rewire my furnace. I ran the wires the same
I am trying to rewire my furnace. I ran the wires the same way they were and now it is popping the breaker. why is that… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
8,290 satisfied customers
One finding in a Property Inspection was the 240VAC 40 amp
One finding in a Property Inspection was the 240VAC 40 amp breaker had 10 ga wire to supply and A/C compressor marked that it required a 40 amp breaker. The inspector notes the wire must be changed to… read more
Mike
Mike
Master Electrician
Working on MBA
1,426 satisfied customers
I am wiring my garage for conversion to a workshop. For normal
I am wiring my garage for conversion to a workshop. For normal use with 110 volt/20 amp breakers...what gauge wire should I use. Also, I have a lincoln electric tig welder 225 that runs on 220 volts. … read more
Electrical Doctor
Electrical Doctor
Master Electrician
Associate Degree
8 satisfied customers
i am wiring a central air conditioner. creating a new supply
i am wiring a central air conditioner. creating a new supply circuit from the breaker panel to a master disconnect box on the outside of the house. what size wire should i use from the breaker to the … read more
Electrical Doctor
Electrical Doctor
Master Electrician
Associate Degree
8 satisfied customers
Can I add a 150 amp wire to the main inside the house
I have a box inside with a 100amp breaker outside (and assuming the wire to thebox is 100amps). The main into the house also feeds an outside breaker with 2-30's and 1-40 amp (total 100). My understan… read more
Electrical Doctor
Electrical Doctor
Master Electrician
Associate Degree
8 satisfied customers
I dont have a question just yet. I think I might find an answer
I dont have a question just yet. I think I might find an answer wiring my pool pump to an intermatic timer. Actually it was working until I wanted to fish an extra line in the same conduit and I short… read more
Glenn
Glenn
Maintenance, Technician
Associate Degree
1,612 satisfied customers
Hi experts out there, We are planning to install a 3.5 ...
Hi experts out there, We are planning to install a 3.5 ton Trane 14 Seer AC with handler. Currently we have a 20 year old 3-ton unit. The electrian estimated that #6 wire will be required for a 3-ton … read more
Electrical Doctor
Electrical Doctor
Master Electrician
Associate Degree
8 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Mike

Mike

Master Electrician

1,426 satisfied customers

Licensed Master Electrician - OnQ Certified Data Voice Audio Video Installer

Jason

Jason

Service Technician

3,958 satisfied customers

Over 20 years of experience in all types of installations, troubleshooting, and repairs.

Mike G.

Mike G.

Master Electrician

8,290 satisfied customers

Proven Professional 49 years Experience

Kevin

Kevin

Licensed Electrical Contractor

4,414 satisfied customers

31 years Licensed Electrical Contractor in Illinois, Adjunct College Electrical Instructor, Former Electrical Inspector, Diploma: Digital Electronics, FCC Technician License

AssuredElectrical

AssuredElectrical

Master Electrician

3,264 satisfied customers

Contractor-42+ Years in the ElectricalTrade

electrifier

electrifier

Master Electrician

1,458 satisfied customers

Electrical contractor and electrical inspector for over 24 years with phone and networking expertise

Rich

Rich

Master Electrician

1,117 satisfied customers

Over 35 years residential, commercial, industrial wiring, install, troubleshoot, service, maintain

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x