I have a Tork RZ307 single pole timer switch. I followed
I have a Tork RZ307 single pole timer switch. I followed instructions and hooked up the line in to the black wire, the line out to the blue wire, and the chassis ground to the 120v ground and to the b… read more
Wire Guy Franklin
Wire Guy Franklin
Business Owner
Master Electrician
1,226 satisfied customers
Trying to install Tork RZ307 timer to single pole switch.
Trying to install Tork RZ307 timer to single pole switch. Have two black wires, white bundle, and copper ground in wall. Have identified hot wall wire. … read more
Wire Guy Franklin
Wire Guy Franklin
Business Owner
Master Electrician
1,226 satisfied customers
I have a Tork RZ 307 timer. my wall switch box only have 3
I have a Tork RZ 307 timer. my wall switch box only have 3 wires. A green and 2 black wires. How should I connect the wires to the timer? … read more
Wire Guy Franklin
Wire Guy Franklin
Business Owner
Master Electrician
1,226 satisfied customers
Have Tork 1104 replacing it with intermatic PF1103T. Need
Have Tork 1104 replacing it with intermatic PF1103T. Need wiring crossover instructions? This Is an electrical question not a firearms question.… read more
AssuredElectrical
AssuredElectrical
Electrical Contractor
High School or GED
3,844 satisfied customers
Replace hardwired light timer with electronic timer. How to wire it?
I have a mechanical hard wired timer for an outdoor light that I want to replace with an electronic timer. The existing wiring has 3 wires coming off the mechanical switch - red, white, and black. The… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
I purchased a tork ss700z in wall digital timer for my outdoor
I purchased a tork ss700z in wall digital timer for my outdoor lighting. I am replacing a previous equivalent switch that got burned out during Sandy. I am having a hard time connecting. According to … read more
AssuredElectrical
AssuredElectrical
Electrical Contractor
High School or GED
3,844 satisfied customers
Hi I am installing a leviton 3way digital timer switch (VPT24).
Hi I am installing a leviton 3way digital timer switch (VPT24). I am replacing a Lutron lighting timer. The Lutron has only 4 wires black, red, blue and the ground which is green. The new Leviton has … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
I am trying to install a GE SunSmart Digital Timer (3-way)
I am trying to install a GE SunSmart Digital Timer (3-way) into an existing circuit. The existing circuit, on the 3-way switch that I removed, has white, red, black and green wires. When I hook up the… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
Putting a sunsmart digital timer in and having problems.
Putting a sunsmart digital timer in and having problems. I have not used the red wire. My outlet has black, white and ground. I connected the black and blue together. Ideas?… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
I am tring to install an in-wall digital timer for two 3-way
I am tring to install an in-wall digital timer for two 3-way switches that control the outside lights. I removed the regular switch that has FOUR wires from the box: a red wire (hot), a back wire, the… read more
AssuredElectrical
AssuredElectrical
Electrical Contractor
High School or GED
3,844 satisfied customers
I am replacing a wall switch with a digital timer. The timer
I am replacing a wall switch with a digital timer. The timer has four wires; black, white, red, & green. Outside lights that the timer will be controlling has three wires; black, yellow, and white. Th… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
I am replacing an old wall timer with a GE Smart Digital Timer.
I am replacing an old wall timer with a GE Smart Digital Timer. The old timer had a black wire and a blue wire connected to two black wires from the wall. The new timer however has red, black, white a… read more
Mike
Mike
Master Electrician
Working on MBA
1,426 satisfied customers
I purchased a GE 15088 in wall timer to control the bathroom
I purchased a GE 15088 in wall timer to control the bathroom fan. There are 3 cables coming into the junction box (2 cables that are #14 2/c w/ground & 1 #14 3/c w/ground). The switch that controls th… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
I am installing a ceiling fan. There are four wires from the
I am installing a ceiling fan. There are four wires from the fan: blue, black white and green. Direction say to attach the green to the household ground wire, the blue and black wire to the black hous… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
I am trying to connnect a GE smart digital timer to the wall
I am trying to connnect a GE smart digital timer to the wall switch for my porch light. I've gotten confused with all of the wires. Can someone tell me how?… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
Im trying to install a GE Smart Digital Timer. My old one
I'm trying to install a GE Smart Digital Timer. My old one was a Intermatic SS8 series. The problem is the Intermatic has 3 wires Blue, Black, Red. In the box the blue one was connected to the yellow … read more
Jason
Jason
Service Technician
Associate Degree
4,920 satisfied customers
Answer A timer also needs a neutral (white) to drive it.
"Answer: A timer also needs a neutral (white) to drive it. Hopefully you have some additional whites wire nutted together and pushed to the back of the box, if so you can join a white wire to these an… read more
Mike
Mike
Master Electrician
Working on MBA
1,426 satisfied customers
I am installing an Intermatic ST01C timer switch to replace
I am installing an Intermatic ST01C timer switch to replace a single light switch. Old switch has two red wires coming from box - capped together. There is a bare spot on one of the wires that is conn… read more
Sir Sparks
Sir Sparks
Owner
State & UK Certified Master electri
2,519 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Mike

Mike

Master Electrician

1,426 satisfied customers

Licensed Master Electrician - OnQ Certified Data Voice Audio Video Installer

Jason

Jason

Service Technician

4,920 satisfied customers

Over 20 years of experience in all types of installations, troubleshooting, and repairs.

Mike G.

Mike G.

Master Electrician

9,821 satisfied customers

Proven Professional 49 years Experience

Kevin

Kevin

Licensed Electrical Contractor

6,678 satisfied customers

34 years Licensed Electrical Contractor in Illinois, Adjunct College Electrical Instructor, Former Electrical Inspector, Diploma: Digital Electronics, FCC Amateur & Commercial Radio Licenses

electrifier

electrifier

Master Electrician

1,458 satisfied customers

Electrical contractor and electrical inspector for over 24 years with phone and networking expertise

Rich

Rich

Master Electrician

1,117 satisfied customers

Over 35 years residential, commercial, industrial wiring, install, troubleshoot, service, maintain

mrromex

mrromex

Electrical Technician

281 satisfied customers

over 40 years of all phases related to residential wiring and remodeling

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.