I have a wired in series 8 ft fluorescent F96t12 -2 lamp
I have a wired in series 8 ft fluorescent F96t12 -2 lamp fixtures that I need to replace the ballast from magnetic to electronic. This is in an old building where the fixtures only have 1-red/1-blue w… read more
Jason
Jason
Service Technician
Associate Degree
4,920 satisfied customers
I just want to ask how to convert my 2 flourecent tube to 1,
hi i just want to ask how to convert my 2 flourecent tube to 1, my ballast is SM-2E75-S-3-TP, with black and white in one side and red and blue inthe other side, thanks. … read more
Ronnell Dyson
Ronnell Dyson
3 satisfied customers
Im trying to replace an old ballast (T12)the old wiring has
hello my name is ***** ***** im trying to replace an old ballast (T12)the old wiring has a white /blk on one side and a blue /red on the other ...the new ballast has a white/blk on one side and 2 blue… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
6,678 satisfied customers
Replacing a ballast in 4 bulb fluorescent 40 watt, T12. It
Replacing a ballast in 4 bulb fluorescent 40 watt, T12. It has 2 ballasts. The new ballast looks the same but smaller except the 2 yellow wires are on the same side as the white and black on the old o… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
I am changing he ballast in a fluorescent light fixture, The
I am changing he ballast in a fluorescent light fixture, The current ballast is a Lumi-Kon R140-120 and the intended replacement is a GE T12. Are they compatible and are there any wiring problems The … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
I have a f96t12 electronic ballast I'm trying to install
I have a f96t12 electronic ballast I'm trying to install from a magnetic one. It has 1 black, 1 white, & one red on one end of the new ballast, & 2 blue on the other. One end of the sockets has 1 red … read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
6,678 satisfied customers
Im replacing an old ballast that has black and on one end
Customer: Im replacing an old ballast that has black and white on one end and a blue and red on the other end. My new ballast icn-2p60-n has black and white on one end and TWO blues and one red on the… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
6,678 satisfied customers
Replacing ballast -T12-2 single pin lamp fixtures.
Replacing ballast for F96-T12-2 single pin lamp fixtures. Original ballast power fed from tombstones on one end of fixture, single red and blue ballast connections connected to plunger-end lamp holder… read more
AssuredElectrical
AssuredElectrical
Electrical Contractor
High School or GED
3,844 satisfied customers
I think the hot and neutral is going straight thru all fixtures
I think the hot and neutral is going straight thru all fixtures I want to say 1 blue 1 red was hooked up to one end of ballast but the blk and wht from other end wasn't hooked up to power it was hooke… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
Changing a t12 1 lamp ballasts to t8. 3 wires on old ballast,
Changing a t12 1 lamp ballasts to t8. 3 wires on old ballast, blk, white, blue. Lamps are single pin. How do I wire to a t8 with blk, why, red, blue, and yellow wire… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
I am wiring a GE-240-RS-MV-N-DIY ballast for a 2-20w lamp bulb
I am wiring a GE-240-RS-MV-N-DIY ballast for a 2-20w lamp bulb setup.The fluorescent fixture has 4 bi pin sockets. I hooked up the wires per the diagram on the ballast but it shorted out . The ballast… read more
jasoncollette
jasoncollette
Electrician
Vocational, Technical or Trade School
55 satisfied customers
Hi I have a old ballast with 6 wires, the new ballast has only
Hi I have a old ballast with 6 wires, the new ballast has only 5 wires 1RED, 1Blk, 1Wht, at one end, on the other end 2blue. The old lights have two tubes, So the old ballast is connected at one end 1… read more
electrifier
electrifier
Master Electrician
Bachelor's Degree
1,458 satisfied customers
I am changing an old GE magnetic ballast in a T12, 8FT. 2 lamp
I am changing an old GE magnetic ballast in a T12, 8FT. 2 lamp fixture to an electronic ballast. The old ballast has the black and white wires on one side and a blue and a red wire on the other side. … read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
I am upgrading my burned out magnetic ballasts and fluorescent
I am upgrading my burned out magnetic ballasts and fluorescent tubes with electrical ballasts and new tubes. The new ballasts are GE multi-volt pro-line high performance t12 for line current 120v-277v… read more
Machinc
Machinc
Retired
1,188 satisfied customers
This GE 140RS120 wont light. Both sockets changed out with
This GE 140RS120 won't light. Both sockets changed out with two blue wires inserted into one end of a new T12 socket and two red inserted into the other new socket. The line wires connected obviously.… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
I am trying to wire a new electronic T12 balast to an old
I am trying to wire a new electronic T12 balast to an old fixture. The old fixture has 4 wires. 1 black 1 white 1 red 1 blue. The old balast had 1 wire going to each. The new balast has 1 white 1 blac… read more
ed michaels
ed michaels
designer and manager
engineering/architecture (3 years)
693 satisfied customers
I am changing out a magnetic ballast in a T12 8ft. 2lamp fixture
I am changing out a magnetic ballast in a T12 8ft. 2lamp fixture to an electronic ballast. What is the new wiring diagram? I see the new diagram on top of the ballast but not sure because of the curre… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
Ive been having a problem with my fluorescent light fixture
I've been having a problem with my fluorescent light fixture where the bulbs will barely flicker when I turn on the light switch. I replaced the fluorescent bulbs with new ones but the new ones reacte… read more
Mike G.
Mike G.
Master Electrician
Vocational, Technical or Trade Scho
9,821 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Mike

Mike

Master Electrician

1,426 satisfied customers

Licensed Master Electrician - OnQ Certified Data Voice Audio Video Installer

Jason

Jason

Service Technician

4,920 satisfied customers

Over 20 years of experience in all types of installations, troubleshooting, and repairs.

Mike G.

Mike G.

Master Electrician

9,821 satisfied customers

Proven Professional 49 years Experience

Kevin

Kevin

Licensed Electrical Contractor

6,678 satisfied customers

34 years Licensed Electrical Contractor in Illinois, Adjunct College Electrical Instructor, Former Electrical Inspector, Diploma: Digital Electronics, FCC Amateur & Commercial Radio Licenses

electrifier

electrifier

Master Electrician

1,458 satisfied customers

Electrical contractor and electrical inspector for over 24 years with phone and networking expertise

Rich

Rich

Master Electrician

1,117 satisfied customers

Over 35 years residential, commercial, industrial wiring, install, troubleshoot, service, maintain

mrromex

mrromex

Electrical Technician

281 satisfied customers

over 40 years of all phases related to residential wiring and remodeling

< Previous | Next >

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.