For a 100 amp service what wire size do I use?

Customer Question
I am hooking up new...
I am hooking up new 100 amp service. What wire size do I use for weather head to breaker box - Contra Costa County California
Submitted: 5 years ago.Category: Electrical
Show More
Show Less
Ask Your Own Electrical Question
Answered in 13 minutes by:
5/5/2012
Electrician: Mike G., Master Electrician replied 5 years ago
Mike G.
Mike G., Master Electrician
Category: Electrical
Satisfied Customers: 7,935
Experience: Proven Professional 49 years Experience
Verified
The proper wire size is 2 #2 and 1 #4 Aluminum. If you're using a cable for the riser then that would be a 100A SEU.

Mike G.
Mike G., Master Electrician
Category: Electrical
Satisfied Customers: 7,935
Experience: Proven Professional 49 years Experience
Verified
Mike G. and 87 other Electrical Specialists are ready to help you
Ask your own question now
Electrician: Mike G., Master Electrician replied 5 years ago
100A service requires either of the following

Copper wire 2 #4 and 1 #6
Aluminum wire 2 #2 and 1 #4

See the Code Article below


Ask Your Own Electrical Question
Ask Mike G. Your Own Question
Mike G.
Mike G.
Mike G., Master Electrician
Category: Electrical
Satisfied Customers: 7,935
7,935 Satisfied Customers
Experience: Proven Professional 49 years Experience

Mike G. is online now

A new question is answered every 9 seconds

How JustAnswer works:

  • Ask an ExpertExperts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional AnswerVia email, text message, or notification as you wait on our site. Ask follow up questions if you need to.
  • 100% Satisfaction GuaranteeRate the answer you receive.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

< Previous | Next >

Meet the Experts:

Mike

Mike

Master Electrician

1,426 satisfied customers

Licensed Master Electrician - OnQ Certified Data Voice Audio Video Installer

Jason

Jason

Service Technician

3,942 satisfied customers

Over 20 years of experience in all types of installations, troubleshooting, and repairs.

Mike G.

Mike G.

Master Electrician

7,935 satisfied customers

Proven Professional 49 years Experience

Kevin

Kevin

Licensed Electrical Contractor

3,870 satisfied customers

31 years Licensed Electrical Contractor in Illinois, Adjunct College Electrical Instructor, Former Electrical Inspector, Diploma: Digital Electronics, FCC Technician License

AssuredElectrical

AssuredElectrical

Master Electrician

3,264 satisfied customers

Contractor-42+ Years in the ElectricalTrade

electrifier

electrifier

Master Electrician

1,458 satisfied customers

Electrical contractor and electrical inspector for over 24 years with phone and networking expertise

Rich

Rich

Master Electrician

1,115 satisfied customers

Over 35 years residential, commercial, industrial wiring, install, troubleshoot, service, maintain

< Previous | Next >

Related Electrical Questions
I was replacing a bathroom light w/a LED light and I noticed
Hello, I was replacing a bathroom light w/a LED light and I noticed one of the wires going to the old light was so burnt when untwisting the wire nut the wire broke, the aluminum wire's insulation is … read more
Mike G.
Mike G.
Master Electrician
7,935 satisfied customers
Have 3 cdr awg 2 and 1 cdr awg 4 aluminum wire for a 100 amp
have 3 cdr awg 2 and 1 cdr awg 4 aluminum wire for a 100 amp sub panel. Is this wiring sufficient. distance is less than 2 feet from the main.… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
3,870 satisfied customers
I am looking to run wire to a detached garage. Main panel in
I am looking to run wire to a detached garage. Main panel in house is opposite corner so I need to run 30 feet down one wall and then 25' across. Garage is then 25' from outside corner. So about 90 fe… read more
Sam I
Sam I
Electrician
B.S.
468 satisfied customers
I am looking for the NEC code referencing to the requirement
I am looking for the NEC code referencing to the requirement to use Copper only in facilities. … read more
Mike G.
Mike G.
Master Electrician
7,935 satisfied customers
My house is older and has aluminum wiring. I'm having some
My house is older and has aluminum wiring. I'm having some difficulty getting a new light fixture to light. It's a problem that I have not experienced here before.… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
3,870 satisfied customers
I installed a new wall oven including new 8 gauge wiring to
Hello,I installed a new wall oven including new 8 gauge wiring to the main panel which I just finished replacing. I believe it's a 50 Amp 220 breaker. The wiring I ran is the 3 wire copper stranded pl… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
3,870 satisfied customers
The wire leads coming out of a new double oven don't look
The wire leads coming out of a new double oven don't look like copper, could they be aluminum, or would they be a coated copper? They are stranded, not solid. … read more
Mike G.
Mike G.
Master Electrician
7,935 satisfied customers
When I purchased my home, it had aluminum wiring in it. So
When I purchased my home, it had aluminum wiring in it. So we had the copalum crimping treatment done to the whole house. Now we want to add a few more outlets & lights and I wonder if we need the sam… read more
Mike G.
Mike G.
Master Electrician
7,935 satisfied customers
I am trying to hook up my garage with 2/0 aluminum wire to a
I am trying to hook up my garage with 2/0 aluminum wire to a 200 amp box in the garage. The wire of course has 3 wires one bare and the other 2 not. What do I do with the bare wire hook it up to the n… read more
Mike G.
Mike G.
Master Electrician
7,935 satisfied customers
I have a single phase 30 amp 120 volt standard connector on
I have a single phase 30 amp 120 volt standard connector on my RV. The hydro pedestal is 200 feet from my RV. I need a over the ground, extension cord Preferably at 100 feet lengths times two to make … read more
Mike G.
Mike G.
Master Electrician
7,935 satisfied customers
Underground power line going to water well. Aluminum wire.
Underground power line going to water well. Aluminum wire. 120 ft distance. . 240 volts across two terminals of breaker. only 150 volts at pump. checked individual. approx 130 volts from neutral to on… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
3,870 satisfied customers
I'm going to look at a house where the complaint is lights
I'm going to look at a house where the complaint is lights are flickering. The house was built in 1980 or 1982 so I'm thinking aluminum wiring may not be the issue since I think builders were using co… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
3,870 satisfied customers
I have a new mobile home. It has a 200 amp panel. If I use
I have a new mobile home. It has a 200 amp panel. If I use aluminum wire for my service entrance, what size aluminum wire do I need? … read more
Mike G.
Mike G.
Master Electrician
7,935 satisfied customers
I'm about to install one of your new wall switch. My home is
I'm about to install one of your new wall switch. My home is wired with aluminum wire at the switch. Is there a way that I can override this. Sometime ago I had installed a swtch with no problem, was … read more
Eddie
Eddie
Home Improvement Contractor and Repairs
High School or GED
1,040 satisfied customers
I'm replacing a drop-in range with a newer slide-in range.
Hi, I'm replacing a drop-in range with a newer slide-in range. Both are "3 wire" units. The question I have is about copper vs aluminum wire. The newer range says on the back to only use copper wire. … read more
Jason
Jason
Service Technician
Associate Degree
3,942 satisfied customers
A 1972 home has aluminum wiring. In addition to installing
A 1972 home has aluminum wiring. In addition to installing AlumiConn connectors at all lights, switches, outlets, etc....do the range, ac and water heater outlets need to be completely rewired so the … read more
Mike G.
Mike G.
Master Electrician
7,935 satisfied customers
I am running 4/0 4/0 4/0 2/0 aluminum wire through 3"pvc
i am running 4/0 4/0 4/0 2/0 aluminum wire through 3"pvc conduit 450' with know bends---can you give me some tips on how to pull this through … read more
ProGrade
ProGrade
Electrical Contractor
564 satisfied customers
Aluminum wired home. COPALUM connectors installed 4 years
Aluminum wired home. COPALUM connectors installed 4 years ago. Attempting to install new range hood. When we removed the old range hood, there is no j-box, but COPALUM connectors on the black and whit… read more
Kevin
Kevin
Licensed Electrical Contractor
Diploma
3,870 satisfied customers
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x