Cat 257B with battery drain issue. turn key on d+ terminal…

Customer Question
Cat 257B with battery...

Cat 257B with battery drain issue. turn key on d+ terminal shows 1.6V. Start engine alternator produces 14.5V. turn engine off and battery voltage still avail at d+ terminal (batt voltage - 1V) disconnect battery - cable, wait 10 seconds and draw disappears. without disconnect battery overnight will draw battery down to 7-9 VDC?

Mechanic's Assistant: What is the complete model and serial number of your machine?

CAT0257BPSLK06904

Mechanic's Assistant: Anything else you want the construction mechanic to know before I connect you?

Have changed batteries, alternators, checked diodes. removed all fuses, relays. replaced key switch

Submitted: 25 days ago.Category: Construction and Road Equipment
Show More
Show Less
Ask Your Own Construction and Road Equipment Question
Answered in 1 hour by:
3/31/2018
Mechanic: catmastertech, Technician replied 25 days ago
catmastertech
catmastertech, Technician
Category: Construction and Road Equipment
Satisfied Customers: 2,476
Experience: Field service technician for CAT 19 years.
Verified

Hello,

Have you checked the amperage draw from the battery?

Does your machine have any add-on attachments that use power?

Is this equipped with Product link or the CAT MSS security system?

Normally the issue is the alternator, did you replace it with a CAT part?

Ask Your Own Construction and Road Equipment Question
Mechanic: catmastertech, Technician replied 25 days ago

I would recommend you try disconnecting the following items by removing the fuse to see if the amperage draw will drop when each fuse is removed. This may help isolate the circuit.

F25 HORN

F23 KEY SWITCH

F22 A/C

F24 MISC POWER

F17 HEATER

The cold start relay and the start relay on the engine.

Each of the relays on the left side of the engine bay. You could have up to four relays.

These relays all use a battery power feed to supply power to the controlled circuit.

Also, look at you harnesses for a damaged area where a wire may be pinched and shorting to another circuit.

NOTE: Most battery feed wires are red and marked with numbers from 100 to 119. CAT does have a few exceptions though.

Ask Your Own Construction and Road Equipment Question
Customer reply replied 25 days ago
Amp draw is about 97ma
No attachments
No link, no mss present, C19 connector exposed in cab harness, but no exciter attached, clock display is always on?
Work is at alternator shop, previous alternator disassembledo diodes checked, reassembled, turn off d+ power and no drain.
Customer reply replied 25 days ago
F16 fuse removal results in 50% drop in draw, but does not effect voltage at d+terminal. Main power relay (A) eliminates draw
Mechanic: catmastertech, Technician replied 25 days ago

Is the indicator group working correctly?

Do all lights self-test at key on?

Ask Your Own Construction and Road Equipment Question
Customer reply replied 25 days ago
Harness looks ok with visual, issue is circuit (d+) does not dis connect with key switch, remaining at battery voltage -1 volt until relay 1 or battery is disconnected
Mechanic: catmastertech, Technician replied 25 days ago

D+ wire is a yellow wire marked C444 correct?

This is the feed to the indicator group in the upper right console. I have replaced a few of these but, they had failed. I haven't replaced one specifically due to battery issues though.

Ask Your Own Construction and Road Equipment Question
Customer reply replied 25 days ago
Indicator group appears ok-hour meter display is always on???
All functions appear n ormal
Yellow wire is C444E26 from splice with C444E27 (from resistor )
Mechanic: catmastertech, Technician replied 25 days ago

Yes, hour meter will stay on as long as the battery is connected. This is normal.

C444 does tie to a resistor and a diode in the D+ circuit.

I assume you have a schematic and can test the complete circuit?

Ask Your Own Construction and Road Equipment Question
Customer reply replied 25 days ago
Done, all components wired correctly and test ok (diodes ok, resistance within tolerance
Mechanic: catmastertech, Technician replied 25 days ago

The main relay A connects to the fuse panel with the shutoff solenoid relay. Have you tried removing that relay and/or testing the shutoff solenoid for a current draw?

Ask Your Own Construction and Road Equipment Question
Customer reply replied 25 days ago
Don't know where those relay and solenoids are? Fuse panel? Fuel shut off?
EC3?
Mechanic: catmastertech, Technician replied 25 days ago

Look for fuse F18 and relay 1. It should be the panel with the black connectors as the other fuse and relay panels have different colored connectors.

Ask Your Own Construction and Road Equipment Question
Mechanic: catmastertech, Technician replied 25 days ago

See attached image

Fuses and Relays

  • Fuses

     

  • (2) Finger Trigger for the Work Tool

     

  • (3) Front Work Lights

     

  • (4) Rear Work Lights

     

  • (5) Left Tail Lamp

     

  • (6) Right Tail Lamp

     

  • (7) Spare

     

  • (8) Backup Alarm

     

  • (9) Cold Start

     

  • (10) Radio

     

  • (11) Spare

     

  • (12) Spare

     

  • (13) 12 volt power socket

     

  • (14) Hydraulic Quick Coupler

     

  • (15) Wiper

     

  • (16) Auxiliary Hydraulic ECM

     

  • (17) HVAC Blower Fan and the Solenoid for the Compressor

     

  • (18) Fuel Shutoff solenoid

     

  • (19) Interlock ECM

     

  • (20) Beacon

     

  • (21) Gauges

     

  • (22) The fan for the air conditioner condenser

     

  • (23) Ignition Switch

     

  • (24) Miscellaneous Power

     

  • (25) Horn

     

  • (27) Auxiliary Hydraulic C-

     

  • (28) Auxiliary Hydraulic C+

     

  • (29) Auxiliary Tools

     

  • (30) Auxiliary Electrical Control C1

     

  • (33) Spare

     

  • (34) Auxiliary Electrical Control C2

     

  • Relays

     

  • (1) Finger Trigger for the Work Tool

     

  • (26) Auxiliary Hydraulic C-Solenoid

     

  • (31) Auxiliary Electric Control C1

     

  • (32) Auxiliary Hydraulic C+Solenoid

     

  • (35) ECM signal for the Auxiliary Hydraulic C+ and the Auxiliary Hydraulic C-

     

  • (36) Auxiliary Electric Control C2

     

  • Diodes

     

  • (37) C-

     

  • (38) C+
Ask Your Own Construction and Road Equipment Question
Customer reply replied 25 days ago
Thanks for the info, will need some time to check so things. Can I re'initiate this tomorrow?
Mechanic: catmastertech, Technician replied 25 days ago

Yes, I should be home most of the day. If not, I will reply as soon as possible.

Ask Your Own Construction and Road Equipment Question
Customer reply replied 25 days ago
Ok, it's Easter Sunday. I'll be looking for eggs☺
Mechanic: catmastertech, Technician replied 25 days ago

Ok, good luck. Maybe you can catch that bunny too!

Ask Your Own Construction and Road Equipment Question
Customer reply replied 24 days ago
Forget prior discussion re alternator, correct bench test analysis reveals matching results on machine. AM voltage of battery >9V. (Key not activated) Primary draw removed when fuse 24 (misc pwr) is removed, unable to determine from schematics what is connected to fuse 24.
Mechanic: catmastertech, Technician replied 24 days ago

That fuse is to the A pin of the ET connector,

the dome lamp and

the hour meter B+.

It also is to the connector for the MSS security connector.

Ask Your Own Construction and Road Equipment Question
Mechanic: catmastertech, Technician replied 24 days ago

122 A82 RED wire

to 122 PA91 RED wire

to 122 C19 RED wire ties to Dome 122-C48 red wire

and hour meter 122-C49 B+

Ask Your Own Construction and Road Equipment Question
Customer reply replied 24 days ago
Checking those circuits.
Mechanic: catmastertech, Technician replied 24 days ago

Ok, I will be here for the rest of the day

Ask Your Own Construction and Road Equipment Question
Customer reply replied 24 days ago
With fuse reinstalled, battery voltage @ 12.3 (from 12.6) during testing (known good shop battery, not machine battery. Disconnect hour meter and dome light power leads and draw continues
Customer reply replied 24 days ago
Key switch must be activated (on position-no start) to reinitiate draw?
Mechanic: catmastertech, Technician replied 24 days ago

I would next look for the CONN 8 connector and check for a short on the wiring to the MSS connector.

This should be on the platform harness near the cab pivot area of the firewall. Near the center of the machine. LOC 34 on the schematic.

Also, inspect the ET connector for damage or moisture.

Yeah, I don't get how the key switch cycle must be activated to create the draw again. The only idea I have is a wire short in a harness that trips either the alternator or an ECM.

Did you try removing the fuel shutoff connection or its diode block?

Ask Your Own Construction and Road Equipment Question
Customer reply replied 24 days ago
I did remove F18, didn't seem to affect drain?
Mechanic: catmastertech, Technician replied 24 days ago

After the key cycle, does any power remain on the other fuses, not on the battery circuits?

Have you checked the ECM's for power when the key is off? They have B+ markings but the circuit is still only on the KEY ON side of the fuses.

Ask Your Own Construction and Road Equipment Question
Customer reply replied 24 days ago
Will have to reassemble upper cab controls ( again ) to inspect harness at pivot area. Thanks for your patience ☺
Mechanic: catmastertech, Technician replied 24 days ago

No problem, just keep me posted on your progress.

Ask Your Own Construction and Road Equipment Question
Customer reply replied 24 days ago
I'll check the ecm power and advise.
Customer reply replied 24 days ago
Ever feel like you have been chasing your tail??? With 4 primary relays Disconnected and all major sub systems fuses out I still show 11V passing between DVM in series with ground at battery and negative cable.
Voltage disappears when B+ and D+ WIRES ARE diconnected from alternator key on and after. I'll have Mach owner order CAT oem and see what up. Have a good evening.
Mechanic: catmastertech, Technician replied 24 days ago

Yes, I do have those days too! It is crazy how often the "almost to spec" or "should be close enough" will drive us nuts!

That is why I don't have hair on my head anymore!

The alternator has been updated but it was years ago, like S/N 390 when they changed them out. Shouldn't be an issue unless the rebuild sheets are using old info and parts.

It did mention diodes but said the issue was "not charging" as the reason for the change.

Thanks for the update. Just let me know when you want to close this question.

Ask Your Own Construction and Road Equipment Question
Was this answer helpful?
Ask Curtis B. Your Own Question
Curtis B.
Curtis B.
Curtis B., Technician
Category: Construction and Road Equipment
Satisfied Customers: 1,362
1,362 Satisfied Customers
Experience: Technican turned service manager with multiple lines of equipment and rental units.

Curtis B. is online now

A new question is answered every 9 seconds

How JustAnswer works:

  • Ask an ExpertExperts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional AnswerVia email, text message, or notification as you wait on our site. Ask follow up questions if you need to.
  • 100% Satisfaction GuaranteeRate the answer you receive.

JustAnswer in the News:

Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.

What Customers are Saying:

Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn't be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

He answered my question promptly and gave me accurate, detailed information. If all of your experts are half as good, you have a great thing going here.

DianeDallas, TX

< Previous | Next >

Meet the Experts:

Curtis B.

Curtis B.

Technician

1,362 satisfied customers

Technican turned service manager with multiple lines of equipment and rental units.

Wayne

Wayne

Journeyman

615 satisfied customers

worked on many road graders, Bull dozers , skid steers, Rollers

Cat Man

Cat Man

Cat Engine Expert

495 satisfied customers

I am ASE Master Certified.

dieseldan55

dieseldan55

Mechanic

270 satisfied customers

Road Mechanic for Volvo Construction Equipment.

Chris (aka- Moose)

Chris (aka- Moose)

Technician

42 satisfied customers

16 years of experience

Steve

Steve

Mechanic

42 satisfied customers

Heavy Equipment Mechanic for 25 years

JBFixxer

JBFixxer

Mechanic

20 satisfied customers

16+ years experience, hydraulics,hydrostatics, engines, fuel injection systems. And everything in between.

< Previous | Next >

Related Construction and Road Equipment Questions
I have cat v155c fork lift. when it warms up the
I have cat v155c fork lift. when it warms up the transmission starts to slip. I can back it up ,but it will not go forward if I rev it up it will try to move forward… read more
Dan
Dan
Auto Mechanics 1&2/diesel mech
Deere 4640 keeps blowing power shift valve gasket between
John Deere 4640 keeps blowing power shift valve gasket between two of the ports. After it blows, pressure is getting to clutch packs and causing drag in all gears except 7 and 8. The only other proble… read more
Dan
Dan
Auto Mechanics 1&2/diesel mech
I have a TH 514 telehander. Been working fine but get in it
Been working fine but get in it today and won't go any faster than idle … read more
Dan
Dan
Auto Mechanics 1&2/diesel mech
I have a v155c forklift. after using it for about half a
I have a v155c forklift. after using it for about half a hour the trans starts to slip.if I give it more gas and then let off , it will more a little bit … read more
timothy ratcliff
timothy ratcliff
t3
Vocational, Technical or Trade School
11 satisfied customers
I am working on a 12e motorgrader serial number 99e9553. I
I am working on a 12e motorgrader serial number 99e9553. I am looking for the procedure to adjust he clutch.… read more
Curtis B.
Curtis B.
Technician
1,362 satisfied customers
I have a KX 121 -3 kubota excavator. All hydraulic seems to
I have a KX 121 -3 kubota excavator. All hydraulic seems to be ok but walking is weak on both tracks. After running a bit it barely will turn… read more
Dan
Dan
Auto Mechanics 1&2/diesel mech
I have a terex telehandler th0806a serial 8322 8000lb lift
I have a terex telehandler th0806a serial 8322 8000lb lift when u put it in foward or reverse it moves but is real slow in all three gears gets worse after it gets out is their a transmission pump wha… read more
Dan
Dan
Auto Mechanics 1&2/diesel mech
How do you remove a heater blower fan on a s205 Bobcat? S205
how do you remove a heater blower fan on a s205 Bobcat? … read more
Jeremy
Jeremy
Technician
Vocational, Technical or Trade Scho
104 satisfied customers
Got cut off-would like to finish this...Another question
Got cut off-would like to finish this...Another question please and I will add another fee to this post. My 350A is a JD made in Germany with a roto-diesel pump. I only have a service manual for a 350… read more
Curtis B.
Curtis B.
Technician
1,362 satisfied customers
Quite awhile ago I took the alternator off of my 5575 skid
quite awhile ago I took the alternator off of my 5575 skid steer. I know where the red wire goes, I khow where the plug in goes and the small wire that has a slip on connection I know where that goes.… read more
Wayne
Wayne
Journeyman
Vocational, Technical or Trade Scho
615 satisfied customers
The track on my yard excavator-Hynduai 210xl-3- keeps
the track on my yard excavator-Hynduai 210xl-3- keeps backing 0ff and has … read more
Dan
Dan
Auto Mechanics 1&2/diesel mech
I have a E70 does this have neg ground or neg positive,
I have a E70 does this have neg ground or neg positive … read more
Dan
Dan
Auto Mechanics 1&2/diesel mech
I am looking to buy a gehl 6625 sx skid loader to use
I am looking to buy a gehl 6625 sx skid loader to use cleaning up an old farm site. The owner said one side quit driving all of a sudden so I jacked up that side and it seems like the chain is still o… read more
Dan
Dan
Auto Mechanics 1&2/diesel mech
Looking for verification on how to find TDC to adjust valves
Looking for verification on how to find TDC to adjust valves on JD 350A with 152 ci diesel. Procedure is to have #1 cylinder at top and then pin the flywheel. Since 4 stroke, still not comfortable if … read more
Curtis B.
Curtis B.
Technician
1,362 satisfied customers
Do you have a ct d5n transmission expert? Cat. Complete
complete rebuild and now it's banging and the tracks stop between shifting in between gears … read more
Dan
Dan
Auto Mechanics 1&2/diesel mech
I have a Deutz 135 ph about 2003 model and have just
I have a Deutz 135 ph about 2003 model and have just replaced the handbrake cables. The two red warning lights on the dash are now not working. I checked the fuses and also put a tester on the handbra… read more
Dan
Dan
Auto Mechanics 1&2/diesel mech
I have a 24V system in my Deere 3020 with a 12V light
I have a 24V system in my John Deere 3020 with a 12V light system. Last spring I blew all my lights out. I bought a 24V to 12V converter to prevent this from happening again. Do I put the converter on… read more
Jeremy
Jeremy
Technician
Vocational, Technical or Trade Scho
104 satisfied customers
I have an 07 420 EIT cat backhoe. the hydraulics quit, the
hi i have an 07 420 EIT cat backhoe. the hydraulics quit, the fuse for the lock out and ride control fuse was blown, im wondering if there is a common spot for this wireing to short out..?? i do not h… read more
Dan
Dan
Auto Mechanics 1&2/diesel mech
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.

Show MoreShow Less

Ask Your Question

x