do you mean my servo pressure from levers ,if so they are fine and is sending down pressure problem is I have too much pressure in neutral
Sk1020-5
S no 37c f00159
Checked that and it is fine.looped the pressure pipe from the pump to the tank pipe and it flowed perfect
Thats my question took valve block out and stripped every valve and all looked fine and smooth cleaned every port and steam washed it out . Can not fimd anything
Are all pilot lines off valve? No pressure from any?Have you air checked valve on bench? Should be matter of finding which valve spool is not centered.??
Did all Of what you said and spools returned to centre opened up oulet pipes and no flow while pressure was high
Hi dan
Thanks for replying. Checked the return pipes and all is fine .servo pressure is fine and work equipment pump is fine .work equipment pump is a gear pump so is not variable and dose not depend on a signal from valve block
Good Morning and thanks for the update. This is a load sensing hydraulic system. According to your serial number this is your main pump. There is a standard and a high flow pump for this machine. Let me know id this looks like the main pump on your machine. The other picture shows the pilot pump mounted to the end of the main pump.