We have an older system with back boiler. The system is

Customer Question

we have an older system with back boiler. The system is controlled by a Drayton 7 controller. The issue we have is recently we are having hot water but no heating and very occasionally the other way around. If the heating is on eventually the boiler might fire up and the heating comes on. I know there is a motorised valve on the system. Could this be the issue? Any help much appreciated. Thanks.
Submitted: 1 year ago.
Category: UK Plumbing
Expert:  Andrew Smith replied 1 year ago.

Does the motorised valve have 2 or 3 pipes?

Do you have a room stat and a cylinder stat?

Customer: replied 1 year ago.
Hello AndrewThanks very much for your reply.From memory the valve has three pipes, i think it is this one:http://www.screwfix.com/p/drayton-ma1-679-3-3-port-motorised-valve/81844?kpid=81844&cm_mmc=Google-_-Product%20Listing%20Ads-_-Sales%20Tracking-_-sales%20tracking%20url&cm_mmc=Google-_-Shopping%20-%20Heating%20and%20Cooling-_-Shopping%20-%20Heating%20and%20Cooling&gclid=CNPSzabNhskCFVG6Gwod-nUH1wIt is under the floor in the bathroom and i will take the floor up tomorrow to access it to check.Yes there is a room stat in the hall and a stat on the hot water cylinder.The wiring is in a box in the airing cupboard.The control system was bought as a kit including all the above and the controller maybe 10 years or more ago.Turning the water on fires up the boiler and heats the water. Turning the heating on does nothing except light up the controller to tell us it is on. Sometimes but not always after an hour or more the boiler may fire up and the heating works.Thanks again for your reply.
Customer: replied 1 year ago.
Hello Andrewjust an update, i got access to the valve today (it was a mid position one) and changed the actuator and now all seems fine.Thanks again for the reply though it is appreciated.
Expert:  Andrew Smith replied 1 year ago.

No problem.

Come back if you need me again, or you get stuck

Related UK Plumbing Questions