I have an Ideal ICOS HE15 boiler, and it has started to make

Customer Question

I have an Ideal ICOS HE15 boiler, and it has started to make a loud clicking and banging noise. The heating and hot water work fine. However, the boiler sometimes sounds like it is about to go bang. I have read it could be kettling and to use some kind of clearer to remove any deposit build up. In addition to this, I have noticed the boiler always has the flashing C displayed, and fires up even when the timer is off. Any ideas of what to check before spending money on a plumber.
Submitted: 1 year ago.
Category: UK Plumbing
Expert:  Andrew Smith replied 1 year ago.

If the boiler is displaying C, then there is no demand and it is probably just keeping the plate heat exchanger up to temperature so there is not a long lag when opening the tap.

You should check the plate heat exchanger is not scales to start with

Customer: replied 1 year ago.
Would this account for the banging noise too?
Expert:  Andrew Smith replied 1 year ago.

Banging is due to poor circulation or blocked heat exchanger, the water is boiling as it is moving too slow

Customer: replied 1 year ago.

Would you recommend draining and then using Sentinel X800 Ultimate Cleaner to remove any sludge?

Expert:  Andrew Smith replied 1 year ago.

The descaler is good, but you have to remove the heat exchanger and place it in a bucket with it