Ask Andrew Smith Your Own Question
Andrew Smith
Andrew Smith, Engineer
Category: UK Plumbing
Satisfied Customers: 3586
Experience:  Domestic Gas, Commercial Gas, LPG, Unvented Hot Water, Part P Electrical, Commercial Catering
46681511
Type Your UK Plumbing Question Here...
Andrew Smith is online now
A new question is answered every 9 seconds

Baxi 105e Hot water only works when heating on Pin is not

Customer Question

Baxi 105e
Hot water only works when heating on
Pin is not coming out far enough to meet micro switch
Changed diaphragm still the same
Submitted: 1 year ago.
Category: UK Plumbing
Expert:  Andrew Smith replied 1 year ago.

If the pin is still not coming out enough then there is a restriction in the divertor valve and it is best to replace the whole thing

Customer: replied 1 year ago.
Divertor valve ok
There's a cartridge at the cold inlet part num 248051
Cost of Venturi cartridge £15
Expert:  Andrew Smith replied 1 year ago.

Does the pin come out if you run 2 taps

Customer: replied 1 year ago.
No just the same
Expert:  Andrew Smith replied 1 year ago.

Try removing the cartridge on the cold inlet to see if you can get the flow rate through the boiler.

See if you can measure the time to fill a bucket before and after

Related UK Plumbing Questions