Following a power cut my Glow worm 30hxi refuses to fire up

Customer Question

Following a power cut my Glow worm 30hxi refuses to fire up on commands from the control device. It will only fire up to heat the water once a tap starts running to bring it back up to temperature and then shuts down again once the tap is shut off. Any ideas?! Thanks
Submitted: 1 year ago.
Category: UK Plumbing
Expert:  Andrew Smith replied 1 year ago.

The boiler should only fire if there is a demand.

This is a heat only boiler so you have a cylinder and radiators, the room stat, cylinder stat and motorised valve fire the boiler.

When on heating only the motorised valve should be fully open (as in the lever slack)