My Boiler will not fire up the central heating even when i

Customer Question

My Boiler will not fire up the central heating even when i put my room thermostat to full, however boiler fires up for water heating no problems, originally thought was 3 position valve so changed to new one.
Submitted: 2 years ago.
Category: UK Plumbing
Expert:  Andrew Smith replied 2 years ago.
Hi my name is XXXXXX - lets see if we can get you sorted in the shortest possible time. Can you let me know the make and model of the boiler?
Customer: replied 2 years ago.

Boiler is Glowworm 15HXI

Control Panel Sunvic SP2

Thermostat ( room) Sunvic PLX

Have just replaced Sunvic 2701 3 pos valve

Expert:  Andrew Smith replied 2 years ago.
What happens when you have both the hot water and heating on and then turn off the hot water at the clock?
Customer: replied 2 years ago.

the boiler stops operating

have turned heating off on controller and water on and the boiler works fine.

but turning water off and heating on and room thermostat to full the boiler will not fire up.

you can hear the thermostat click!when on full

Expert:  Andrew Smith replied 2 years ago.
Can you tell me what happens when you have the hot water and heating on and then turn the hot water off at the cylinder thermostat?
Customer: replied 2 years ago.
wont be able to do that until later tonight as i am in work now, however from what i have learnt already the cylinder stat has no on/off just a dial that seems to go round and round with no definable stop on it
Expert:  Andrew Smith replied 2 years ago.
OK, you need to replace that. The power for the 3 port goes through that also, so when your hot water is satisfied and turns off it is supposed to send a signal back to the 3 port.
Customer: replied 2 years ago.
ok will try that
Expert:  Andrew Smith replied 2 years ago.
Let me know how you get on.
Customer: replied 2 years ago.
Thank you i will
Expert:  Andrew Smith replied 2 years ago.
No problem
Customer: replied 2 years ago.
Changed cylinder stat, checked new one working ok, turned cylinder stat to off position , central heating will still not fire up
Expert:  Andrew Smith replied 2 years ago.
Central heating will not fire up when on at the clock and room thermostat and the hot water off - it is either a problem with the clock, the room thermostat (as this is where the power comes from) or the wiring to the 3 port valve. Do you have a diagram to check it against?
Customer: replied 2 years ago.

checked wiring then double checked all seems as it should be,

im not sure how to check room thermostat for power to 3 pos valve

or control panel for +ve feed

Expert:  Andrew Smith replied 2 years ago.
Room stat should be live on 1 and then out on 3;
http://www.honeywelluk.com/Documents/All/pdf/940.pdf
If you get stuck I can talk you through this wire by wire.
Customer: replied 2 years ago.
live as in 240 v
Expert:  Andrew Smith replied 2 years ago.
When you turn the thermostat up do you get power back down 3. Did you get the diagram OK?
Customer: replied 2 years ago.

got diagram thank you unable to check until this evening due to work commitments, why does work always get in the way!,

you are not required to answer the last question by the way

Expert:  Andrew Smith replied 2 years ago.
Just drop me a line when you get round to it.
Customer: replied 2 years ago.

Andrew

good morning

having now tested my system and checking wiring is same as PDF this is what i have found

when cylinder stat is calling i have 235v going to orange wire of 3 way valve

and 168v going to grey of 3 way valve.

when cylinder stat satisfied or off i have 235v to grey wire and 0 v to orange wire.

 

when CH calling i have 237v to white of 3 way valve

and 236v to grey of valve.

when CH satisfied or off i have 40v to white of valve.

the plot thickens

Expert:  Andrew Smith replied 2 years ago.
The 168V - ish is usual when the valve is sat in some positions. I will look into this deeper.

JustAnswer in the News:

 
 
 
Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.
 
 
 

What Customers are Saying:

 
 
 
  • You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future. Jimmy Bagley, IA
< Last | Next >
  • You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future. Jimmy Bagley, IA
  • Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help. Mary C. Freshfield, Liverpool, UK
  • This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!! Alex Los Angeles, CA
  • Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult. GP Hesperia, CA
  • I couldn't be more satisfied! This is the site I will always come to when I need a second opinion. Justin Kernersville, NC
  • Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around. Esther Woodstock, NY
  • Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know. Robin Elkton, Maryland
 
 
 

Meet The Experts:

 
 
 
  • Rick Ridley

    UK Heating Engineer

    Satisfied Customers:

    1559
    30 Years on the tools, now retired, Ex CORGI
< Last | Next >
  • http://ww2.justanswer.com/uploads/solarman1947/2009-12-13_223915_phpkKBcXq_c2PM.jpg Rick Ridley's Avatar

    Rick Ridley

    UK Heating Engineer

    Satisfied Customers:

    1559
    30 Years on the tools, now retired, Ex CORGI
  • http://ww2.justanswer.com/uploads/CH/chamberlains/2011-6-11_181053_Photoon20110611at19.06.64x64.jpg Chamberlain Maintenance's Avatar

    Chamberlain Maintenance

    Plumber

    Satisfied Customers:

    310
    Qualified Plumber with over 17 years experience in Domestic & Commercial plumbing.
  • http://ww2.justanswer.com/uploads/QW/qwasert/2011-11-24_221527_ben.64x64.JPG qwasert's Avatar

    qwasert

    Plumber

    Satisfied Customers:

    187
    Condensing and Combi Boilers
  • http://ww2.justanswer.com/uploads/VE/Veillplumb/2011-8-31_155028_IMG1104.64x64.JPG Marc's Avatar

    Marc

    Plumber

    Satisfied Customers:

    122
    Plumbing and Heating expert with 25+ years experience, 21+yrs self employed as a contractor.
  • http://ww2.justanswer.com/uploads/JA/JACUSTOMER4xr7932a/2011-11-12_2244_SmallFacePhoto.64x64.jpg Ardent Engineering's Avatar

    Ardent Engineering

    Engineer

    Satisfied Customers:

    49
    Registered Gas Installer
  • http://ww2.justanswer.com/uploads/DA/DanRobinson/2012-5-13_221341_Me.64x64.JPG Dan_Robinson's Avatar

    Dan_Robinson

    Plumber

    Satisfied Customers:

    33
    Owner and Director of Jennings Heating Ltd. Registered to work with Gas and High pressure hot water systems.
  • /img/opt/shirt.png Brian's Avatar

    Brian

    Plumber

    Satisfied Customers:

    400
    16 yrs. experience as plumber, including full bathroom and kitchen installations.