How JustAnswer Works:
  • Ask an Expert
    Experts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional Answer
    Via email, text message, or notification as you wait on our site.
    Ask follow up questions if you need to.
  • 100% Satisfaction Guarantee
    Rate the answer you receive.
Ask Andrew Smith Your Own Question
Andrew Smith
Andrew Smith, Engineer
Category: UK Plumbing
Satisfied Customers: 3626
Experience:  Domestic Gas, Commercial Gas, LPG, Unvented Hot Water, Part P Electrical, Commercial Catering
46681511
Type Your UK Plumbing Question Here...
Andrew Smith is online now
A new question is answered every 9 seconds
UK Plumbing

Glow-Worm 30 CXI Flashing F12 anybody know whats wrong and

how to put it right
Submitted: 5 years ago.
Category: UK Plumbing
Ask Your Own UK Plumbing Question
Rick Ridley, UK Heating Engineer
Satisfied Customers: 2708
Experience: 30 Years on the tools, now retired, Ex CORGI
replied 5 years ago.
Hi I am Rick, UK Plumber, and I specialize on Boiler problems, F12 is a connection problem between the user interface (small board with several potentiometers on it) and the main board possibly a pulled connector or a broken or corroded wire, Rick
Customer reply replied 5 years ago.
I can get that much information from boiler manual
Andrew Smith, Engineer
Satisfied Customers: 3626
Experience: Domestic Gas, Commercial Gas, LPG, Unvented Hot Water, Part P Electrical, Commercial Catering
replied 5 years ago.
Hi my name is Andrew - lets see if we can get you sorted in the shortest possible time. Can you pull the connector off the main pcb and check that the connections are clean and look ok. If you can see and burnt marks on the smaller pcb or cannot see a fault at all then my first point would be to replace it
Customer reply replied 5 years ago.
Sorted it myself through trial and error connection on main PCB not making contact.Very poor idea,crap boiler.
Andrew Smith, Engineer replied 5 years ago.
The cxi's and the hxi's are very poor in build quality. I am glad you sorted it, but try and save up for a new one.