baxi duo tec combi he .no hot water. have turned switch of

Customer Question

baxi duo tec combi he .no hot water. have turned switch of and then anti clockwise for ten seconds.e1 33 flashing.
Submitted: 6 years ago.
Category: UK Plumbing
Expert:  Rick Ridley replied 6 years ago.
Hi I am Rick, UK Plumber, f1 33 =flame failure, if you turn the selector switch (left hand one) off for 5 seconds or so then to on again it should clear this fault, you should then hear the fan then sparking then burner light, Regards Rick