How JustAnswer Works:

  • Ask an Expert
    Experts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional Answer
    Via email, text message, or notification as you wait on our site.
    Ask follow up questions if you need to.
  • 100% Satisfaction Guarantee
    Rate the answer you receive.

Ask StructuralEng Your Own Question

StructuralEng
StructuralEng, Consultant
Category: Structural Engineering
Satisfied Customers: 6808
Experience:  Structural Engineer
59685895
Type Your Structural Engineering Question Here...
StructuralEng is online now
A new question is answered every 9 seconds

17ft wall load bearing wall between living room and kitchen

Customer Question

17ft wall load bearing wall between living room and kitchen to remove open consept .one ceilling 16 ft wide other 11 ft ,wall holds up 2 upstairs room and roof
Submitted: 8 months ago.
Category: Structural Engineering
Expert:  StructuralEng replied 8 months ago.
Hello
Expert:  StructuralEng replied 8 months ago.
I can help
Expert:  StructuralEng replied 8 months ago.
Does it support the roof or just the second floor and attic? It's atypical for an interior wall to support the roof?
Customer: replied 8 months ago.
just the 2 upstairs floors and atic
Expert:  StructuralEng replied 8 months ago.
Two rooms, but only one level, correct. One floor level plus the attic?
Customer: replied 8 months ago.
thats right
Expert:  StructuralEng replied 8 months ago.
You will need a 7" X 16" 2.0E LVL to work for strength and limit deflection to L/360 under a full design load
Customer: replied 8 months ago.
that what i thought irs been 19 years and my math was rusty thank you for your help
Expert:  StructuralEng replied 8 months ago.
No problem. I'm happy to help. Good luck with your project.