Stl. Beam Design: (Residential) holding 2nd floor Area (22.5'x18.5'x(half

Customer Question

Stl. Beam Design: (Residential) holding 2nd floor Area (22.5'x18.5'x(half of which is on conc found. both sides. ).5= 209 sf.)
2x8 clg. joists span 22'-6" from end to end.. Flush beam if possible will pick up 18'-6" of clear span.
Bedroom above with a bath in 1st 3rd of beam. 2nd fl. 2x4 Partition parallel to beam 3'-0 into span/ [7'-6" 2nd fl. clg. hgt. h-Plaster-wood lath mat'l.
2nd fl. clg joists 2x6. bear on 2x4 partition.
No roof load.
will an WF 8x ? work?
Submitted: 6 months ago.
Category: Structural Engineering
Expert:  StructuralEng replied 6 months ago.
Hello
Expert:  StructuralEng replied 6 months ago.
I can help
Customer: replied 6 months ago.
HELLO ?
ARE YOU THERE? I DONT SEE AN ANSWER TO THE STEEL BEAM AND POST SIZING
Expert:  StructuralEng replied 6 months ago.
I apologize for the technical difficulty. I posted a couple questions I don't see here.
Expert:  StructuralEng replied 6 months ago.
Is this supporting a singe floor and attic only?
What is the joist length on each side of the beam? Will it support any ceramic tile?
Customer: replied 6 months ago.
CAN I SEND YOU A PDF?
Customer: replied 6 months ago.
HERE IS THE DRAWING
I FIGURED IT CAN HELP
...LIKE TO GET AS FLUSH TO 8" CEILING AS POSSIBLE
Customer: replied 6 months ago.
this IS supporting a singe floor and attic only.
THE joist length on each side of the beam IS 11'
it Will support ceramic tile YES
Customer: replied 6 months ago.
HELLO ?
ARE YOU THERE? I DONT SEE AN ANSWER TO THE STEEL BEAM AND POST SIZING
Expert:  StructuralEng replied 6 months ago.
You will need a W8x28 beam ASTM A882 Gr. 50
Expert:  StructuralEng replied 6 months ago.
Posts can be 4" nominal schedule 40 pipe ASTM A53
Expert:  StructuralEng replied 6 months ago.

Hello. Do you have any other questions for me on thistopic? If you could rate my answer, I would appreciate it.

Expert:  StructuralEng replied 5 months ago.

Hello. If you could rate my answer, I would appreciate it.