Are 2 lvl beams strong enough to span 9 1/2 feet opening,

Customer Question

are 2 lvl beams strong enough to span 9 1/2 feet opening, with one floor above?
Submitted: 1 year ago.
Category: Structural Engineering
Expert:  StructuralEng replied 1 year ago.

Hello. I can size the lvl for you

Expert:  StructuralEng replied 1 year ago.

What is the joist length on each side of the beam?

Expert:  StructuralEng replied 1 year ago.

Will it support any ceramic tile?

Customer: replied 1 year ago.
the joist on one wall are 12 ft on one side 13 ft on the other..no just carpet
Customer: replied 1 year ago.
this is the opening as it is now
Expert:  StructuralEng replied 1 year ago.

Thank you. What about ceramic tile? Will it also support an attic?

Customer: replied 1 year ago.
there is no tile upstairs and the attic space is just open insulation , with nothing in it
Customer: replied 1 year ago.
is your concern about the tile the weight?
Expert:  StructuralEng replied 1 year ago.

My question about the tile was for the deflection limit

Expert:  StructuralEng replied 1 year ago.

You can plan for a 3.5" x 11.25" 1.8E LVL OR A 5.25" x 9.5" 2.0E LVL

Customer: replied 1 year ago.
Ok thank you. If we do 3 beams at 8.5 vertical and 1 3/4 in thick would that work?
Expert:  StructuralEng replied 1 year ago.

They don't make LVL 8.5" . It's 7.25", 9.25", and 9.5". There is no 8.5"

Customer: replied 1 year ago.
we have looked into that...but we were thinking of cutting the height of the lvl to 8.5 so it doesnt go below the suffot framing...we can use a 9.5 lvl if it is okay to remove the 2 top plates? or at least 1 of the top plates? is this possible?
Customer: replied 1 year ago.
Do you have an answere for my last question?
Expert:  StructuralEng replied 1 year ago.

Hello. If you want to cut an LVL to 8.5", you will need it to be 7" wide and 2.2E stress grade. The cut side should go on the top to be in compression.

Customer: replied 1 year ago.
Thank you very much.
Customer: replied 1 year ago.
one more thing...can i remove one of the two top rails and have my header sit under just the 1 top rail?
Expert:  StructuralEng replied 1 year ago.

Potentially, but it would be too difficult to describe how to know if you can