I need to span 6 feet door header only a roof load

Customer Question

hi I need to span 6 feet for a door header only a roof load above I believe 40 pounds per square foot snow load .wanted to use 2- 3 inch x 1.5 c cahhels back to back
Submitted: 1 year ago.
Category: Structural Engineering
Expert:  StructuralEng replied 1 year ago.
What is the city and state so I can look at snow loading?What is the rafter length on each side of the beam? Do you also have attic joists supported by the header?
Customer: replied 1 year ago.
Poughkeepsie ny 12603 also the wall is at the end of the building only ceiling joist and sheathing and shingles above ceiling joist spane 12 feet to the other end wall
Expert:  StructuralEng replied 1 year ago.
12' to the other exterior wall or 12' to the ridge?
Customer: replied 1 year ago.
this is a shed roof
Expert:  StructuralEng replied 1 year ago.
Flat roof?
Customer: replied 1 year ago.
no a 5/10 pitch so there is ceiling joist and roof rafters
Expert:  StructuralEng replied 1 year ago.
You can plan for two C3x6
Customer: replied 1 year ago.
any other way I don't have 6 inchs in height
Customer: replied 1 year ago.
what about metal I beam
Expert:  StructuralEng replied 1 year ago.
They are only 3" deep. The 6 means they each weigh 6 pounds per foot.
Customer: replied 1 year ago.
so is that a 3/16 inch thick c channel my metal shop says only 4.51 pounds per foot
Customer: replied 1 year ago.
that is 4.51 pounds per foot each
Expert:  StructuralEng replied 1 year ago.
Channel flanges taper, they are not constant thickness. There is no C3x4.51 as a standard C shape.
Customer: replied 1 year ago.
ok s a 3 inch by 1.5 inch c channel x 2 will work then
Expert:  StructuralEng replied 1 year ago.
Hello. Do you have any other questions for me on this topic? If you could rate my answer, I would appreciate it.