After tune up, output is some 190-200v per leg. why is

Customer Question

after tune up, output is some 190-200v per leg.
why is output so high?
Submitted: 1 year ago.
Category: Small Engine
Expert:  Hank F. replied 1 year ago.

What is the model number of the genset?

There can be several things that can cause this: engine running too fast, bad voltage regulator or controller (depending on what model it is), damaged stator etc.

Customer: replied 1 year ago.
7NHMFA26105H
SN K000176764
Expert:  Hank F. replied 1 year ago.

Test the frequency. It should be set to about 62 Hz, with no load on the genset.

If the frequency is good, the voltage regulator is bad and will need to be replaced.