What causes the coils to fail? I had two new ones fail after

Customer Question

What causes the coils to fail? I had two new ones fail after 90 minutes of use.
Submitted: 1 year ago.
Category: Small Engine
Customer: replied 1 year ago.
Kohler 26 hp ignition upgrade kit
Expert:  Briggs-Fan replied 1 year ago.
Hi my name is ***** ***** welcome to just answer. Take your ground wire off the coil and put the red lead of a digital multimeter to it , ground the black lead and gave it set to dc volts , flip the key from off to run several times and watch the meter , you shouldn't see ant voltage at all but if you do the ignition switch is bad and back feeding voltage to the ground wire killing the coil .
Customer: replied 1 year ago.
Thanks
Expert:  Briggs-Fan replied 1 year ago.
No problem , let me know what you find
Expert:  Briggs-Fan replied 1 year ago.
We're you able to test it yet ?
Expert:  Briggs-Fan replied 1 year ago.
We're you able to resolve this? ?