Installin g swamp cooler motor its model 67842

Customer Question

installin g swamp cooler motor its model 67842 smith+jones230v wiring it ccw wiring from motor has a p1,p2,t3,t8,t2,t4,t5 wires coming from it with the t3,t8,t2 wired together also t4,t5 together so I have a black a white and green wire so would the p1
go to black t4,t5 to white and green to ground of motor?
Submitted: 1 year ago.
Category: Small Engine
Expert:  Wayne replied 1 year ago.
Hi I'm Wayne I will help you with this is that single Phase, let me know
Customer: replied 1 year ago.
yes
Customer: replied 1 year ago.
dual cap
Expert:  Wayne replied 1 year ago.
Hi Thank you for that
Yes green is motor ground,
the p1
go to black t4,t5 to white
If this helped you, Please rate my answer
3 or more stars
If not, please reply for more info
Thank you
Customer: replied 1 year ago.
problem I am having is motor keeps shuting off after like 30 seconds
Expert:  Wayne replied 1 year ago.
Hi is this the reason you replaced the motor
Customer: replied 1 year ago.
no replaced motor because old one burnt out
Expert:  Wayne replied 1 year ago.
Thank you for that does it pop the breaker or circuit, or just shut off, then restart
Customer: replied 1 year ago.
it just pops the reset button not the breaker
Customer: replied 1 year ago.
reset button on motor
Expert:  Wayne replied 1 year ago.
Hi Sorry for the delay
I was looking this up,
try to reverse the white and black wires
Customer: replied 1 year ago.
ok thank u will try
Expert:  Wayne replied 1 year ago.
OK
Customer: replied 1 year ago.
sorry so long but just seen my input wires are red,blue,green so what to do
Expert:  Wayne replied 1 year ago.
Hi Blue is usually a take off of a black hot wire see if this helps you http://www.perfect-home-hvac-design.com/swamp-cooler-wiring.html
Customer: replied 1 year ago.
so blue would be hot and red common
Customer: replied 1 year ago.
do you have wiring diagram for 220v
Expert:  Wayne replied 1 year ago.
Hi
I sent you the wire diagram
on my last answer
Customer: replied 1 year ago.
07 July 2015 06:47sorry to bother you again wayne but swamp seemed to work fine except after couple mins it kicked down to barely blowing but wait ten mins after shut off start up does same think any ideals
Expert:  Wayne replied 1 year ago.
Thank you for that That sounds to bee a thermostat issue, going into low speed If this helped you, Please rate my answer3 or more stars If not, please reply for more infoThank you