How JustAnswer Works:
  • Ask an Expert
    Experts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional Answer
    Via email, text message, or notification as you wait on our site.
    Ask follow up questions if you need to.
  • 100% Satisfaction Guarantee
    Rate the answer you receive.
Ask poolguy810 Your Own Question
poolguy810
poolguy810, owner - pool and spa service company
Category: Pool and Spa
Satisfied Customers: 1675
Experience:  Servicing pools and all brands of spas for over 28 years.
32482502
Type Your Pool and Spa Question Here...
poolguy810 is online now
A new question is answered every 9 seconds

Working on pool heater.Jandy Lite2, model LJ25CN. SN

Customer Question

Working on pool heater.J***** *****te2, model LJ25CN. SN G04PJ1259, production date 10/2004. Control panel error said the ignitor was bad. Replaced ignitor, still will not run, control panel now shows error message that the control panel is bad. The control panel has been replaced twice within the past year. Checked grounds today, there was one loose. Can you help?
Submitted: 1 year ago.
Category: Pool and Spa
Expert:  HVAC Guru replied 1 year ago.

Hello and thanks for using this service, if you have been waiting do not worry or get upset. I am APPLIANCE-HVAC GURU a very experienced tech on here and I try to get to as many customers as I can. I just picked up your question now.

Please allow time for me to respond, sometimes I get the questions or responses late so please be patient as I have no control over the site issues. NOTE, I have nothing to do with your payment to the site and did not receive that money.

IS this the first time you are using the unit?

Customer: replied 1 year ago.
No, using for years, was produced in 2004.
Expert:  HVAC Guru replied 1 year ago.

What error is coming up?

Customer: replied 1 year ago.
F1
Or FL
Customer: replied 1 year ago.
What is your name
Customer: replied 1 year ago.
Don
Customer: replied 1 year ago.
Now flashing fl. 4
Expert:  HVAC Guru replied 1 year ago.

Check the voltage to the ignitor is it irratic? Often the High voltage board goes bad causing that issue.