I have a la spa with water management system. it got cold

Customer Question

I have a la spa with water management system. it got cold didn't trip any breakers. took out flow sensor checked with ohm meter when open no sound when closed sound. put a tub in the sensor place started the spa and no water came out.
Submitted: 11 months ago.
Category: Pool and Spa
Expert:  Jerry replied 11 months ago.

Sounds like you have it nailed. If the board in putting out 120v to the circ pump but the pump is not running, then you will get a cold tub since there would be no flow and the sensor will not allow the heater to try to come on. You will need to replace the circ pump.

Thanks for using Just Answer. Let me know if still need help.