I have a new Rheem 206 a propane heater. tanks are new and

Customer Question

i have a new Rheem 206 a propane heater.
tanks are new and full and i have gas flow
up to the unit, but the pilot wont light
it stops trying after 90 seonds and gives me a pilot light error message, is there a way i can check to see if the honeywell gas valve is getting propane?
Submitted: 1 year ago.
Category: Pool and Spa
Expert:  Billy replied 1 year ago.

hello,

you can remove the pilot tube from the gas valve...if it is getting gas it will emit from where you removed pilot tube from valve. It takes a long time to "prime" on of these.

Can you try the pilot port check now?

Customer: replied 1 year ago.
Just tell me what to do , i will run outside and do it. where is the pilot port check?, can you call me on my cell?
Customer: replied 1 year ago.
Expert:  Billy replied 1 year ago.

follow the silver tube from the pilot..it is as thick as a pencil...this tube screws into the gas valve. Remove the tube from gas valve and try a cycle

Customer: replied 1 year ago.
i will try this and get back to you in about 15 minutes
Expert:  Billy replied 1 year ago.

just return to this thread when ready

Customer: replied 1 year ago.
i took off the tube you told me to take off and no gas is coming out to supply the pilot light. What should i try next?
Expert:  Billy replied 1 year ago.

Are all valves open? Gas valve on the heater...gas valve shut off in pipe?

if you remove pipe to unit is gas live?

Customer: replied 1 year ago.
i have a pipe coming out of ground with a T on it , one side goes to heater , other is for later on, i opened up the one for
later on and gas is flowing nicely. i may have to disconnect the heater side and see fi something is clogged going into heater.
would you recommend this?
Expert:  Billy replied 1 year ago.

you either have a blockage...or the gas valve is not opening...do you hear the valve click on start up?

Customer: replied 1 year ago.
no , i only her the clicking for the pilot light
Expert:  Billy replied 1 year ago.

thank you,

do you have a meter to see if 24v is going to gas valve?

Customer: replied 1 year ago.
no, i had an electrician here earlier , but i do not think he checked this, all panels and lights and everything else is working.
How can i check without a meter?
Customer: replied 1 year ago.
should i disconnect pipe before valve to see if it is blocked?
Expert:  Billy replied 1 year ago.

yes...take apart up to gas valve as there is a filter screen at valve

Customer: replied 1 year ago.
ok , i will get back to you shortly.
Expert:  Billy replied 1 year ago.

respond as you can

Customer: replied 1 year ago.
where is the filter , is it on the left side where the 3/4 inch pipe goes into valve?
Expert:  Billy replied 1 year ago.

correct

Customer: replied 1 year ago.
ok thanks , i am going to call the guys back that attached everything. let them fix it they charged me enough money.
Thank you again for helping me narrow the problem down.
Expert:  Billy replied 1 year ago.

you are welcome and I wish you the best...just rate service and I will close.

Billy