A new question is answered every 9 seconds

I have an older hot tub and replaced the heating element 2

Customer Question

I have an older hot tub and replaced the heating element 2 weeks ago. it was working fine but the tub shut off a couple days ago. it tripped the breaker 60amp. this is a small 4 person tub. if I reset the breaker and turn off the heater everything runs fine. when I turn on the heater it instantly trips
Submitted: 1 year ago.
Category: Pool and Spa
Expert:  Billy replied 1 year ago.

hello,

this of course means the heater is shorted or wiring to it.

Was the heater properly rated?

Expert:  Billy replied 1 year ago.

.

Customer: replied 1 year ago.
I agree it something with the heater but the stated resistance for the is between 9 and 12 ohms. I'm getting an ohm reading of 10.8. I can't see any wires touching. And the fuses are fine. Can the element still be bad?
Expert:  Billy replied 1 year ago.

unhook the power feed from elements and ohm element wire to ground...tell me if short to ground

Customer: replied 1 year ago.
I am not getting any reading when I check the element wires to the ground.